108 half-cut cells, bifacial, glass (dual-glass module). Power classes 420–460 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| GEO-NM10-54D420 | 420 W | 39.14 | 14.00 | 32.54 | 12.91 | ≈21.5% | 399 W | Oct 1, 2026 |
| GEO-NM10-54D425 | 425 W | 39.25 | 14.08 | 32.80 | 12.97 | ≈21.8% | 404 W | Oct 1, 2026 |
| GEO-NM10-54D430 | 430 W | 39.36 | 14.16 | 33.06 | 13.03 | ≈22.1% | 409 W | Oct 1, 2026 |
| GEO-NM10-54D435 | 435 W | 39.47 | 14.22 | 33.28 | 13.09 | ≈22.3% | 413 W | Oct 1, 2026 |
| GEO-NM10-54D440 | 440 W | 39.59 | 14.28 | 33.50 | 13.15 | ≈22.6% | 418 W | Oct 1, 2026 |
| GEO-NM10-54D445 | 445 W | 39.70 | 14.34 | 33.72 | 13.21 | ≈22.8% | 423 W | Oct 1, 2026 |
| GEO-NM10-54D450 | 450 W | 39.81 | 14.40 | 33.92 | 13.27 | ≈23.1% | 428 W | Oct 1, 2026 |
| GEO-NM10-54D455 | 455 W | 39.93 | 14.46 | 34.14 | 13.33 | ≈23.3% | 433 W | Oct 1, 2026 |
| GEO-NM10-54D460 | 460 W | 40.04 | 14.52 | 34.35 | 13.39 | ≈23.6% | 438 W | Oct 1, 2026 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.293 %/°C |
| Voc coefficient β | −0.258 %/°C |
| Isc coefficient α | +0.035 %/°C |
| Operating cell temperature | NOCT 43.3 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 420 W | 314.9 W | 30.95 V × 10.17 A | 79.8 W | 95% |
| 425 W | 318.9 W | 31.2 V × 10.22 A | 80.8 W | 95% |
| 430 W | 322.9 W | 31.45 V × 10.27 A | 81.8 W | 95% |
| 435 W | 326.5 W | 31.66 V × 10.32 A | 82.7 W | 95% |
| 440 W | 330.2 W | 31.87 V × 10.36 A | 83.6 W | 95% |
| 445 W | 333.9 W | 32.08 V × 10.41 A | 84.6 W | 95% |
| 450 W | 337.4 W | 32.27 V × 10.46 A | 85.5 W | 95% |
| 455 W | 341.1 W | 32.48 V × 10.5 A | 86.4 W | 95% |
| 460 W | 344.8 W | 32.68 V × 10.55 A | 87.3 W | 95% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–14 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–14 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–14 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–11 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 41.9 / 28.1 V | ⚠ Works; below MPPT at peak heat | 1.52 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 41.9 / 28.1 V | ✗ Not a match: module voltage below MPPT range | 1.16 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 41.9 / 28.1 V | ✓ Within range | 0.56 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 41.9 / 28.1 V | ⚠ Works; below MPPT at peak heat | 1.35 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 41.9 / 28.1 V | ⚠ Works; below MPPT at peak heat | 1.26 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 737 | 11,799 | 6.08 |
| Palmdale | 1,835 | 807 | 12,918 | 6.69 |
| Chula Vista | 1,696 | 746 | 11,940 | 6.11 |
| Huntington Beach | 1,643 | 723 | 11,567 | 5.89 |
| Riverside | 1,696 | 746 | 11,940 | 6.21 |
| Santa Clarita | 1,724 | 759 | 12,137 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | Warranty | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|---|
| Geo Solar Technology GEO-NM10-54D 440 | 440 W | ≈22.6% | −0.293 | 39.59 | 14.28 | — | — | — |
| Qcells Q.TRON BLK M-G2+ 440 | 440 W | ≥22.5% | −0.276 | 39.88 | 13.9 | 25 / 25 yr | brand 11× (2016–2026) | 40 |
| Silfab Solar SIL-440QD | 440 W | ≈22.6% | −0.294 | 38.97 | 14.25 | 25 / 30 yr | brand 7× (2017–2025) | 39 |
| Hyundai Energy Solutions HiN-T440NF(BK) | 440 W | ≈22.7% | −0.298 | 38.8 | 14.39 | 25 / 30 yr | brand 5× (2017–2025) | 37 |
Calculated from the panel area (1.95 m²): about 22.6% for the 440 W class. 440 W over 1.95 m² equals about 226 W per square meter.
PVWatts v8 with typical-year weather gives about 737 kWh per year per 440 W panel in Los Angeles and about 807 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.293 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.2% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 41.9 V, Vmp at 74 °C cell = 28.1 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 41.9 V vs max input 60 V; Vmp when hot 28.1 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.