144 cells, bifacial, transparent backsheet. Power classes 525–560 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| GSP7G72M(H)525WT | 525 W | 49.18 | 13.65 | 41.16 | 12.76 | ≈20.5% | 493 W | Mar 21, 2023 |
| GSP7G72M(H)530WT | 530 W | 49.32 | 13.72 | 41.32 | 12.83 | ≈20.7% | 498 W | Mar 21, 2023 |
| GSP7G72M(H)535WT | 535 W | 49.46 | 13.79 | 41.48 | 12.90 | ≈20.9% | 503 W | Mar 21, 2023 |
| GSP7G72M(H)540WT | 540 W | 49.60 | 13.86 | 41.64 | 12.97 | ≈21.1% | 508 W | Mar 21, 2023 |
| GSP7G72M(H)545WT | 545 W | 49.76 | 13.93 | 41.80 | 13.04 | ≈21.3% | 512 W | Mar 21, 2023 |
| GSP7G72M(H)550WT | 550 W | 49.92 | 14.00 | 41.96 | 13.11 | ≈21.5% | 517 W | Mar 21, 2023 |
| GSP7G72M(H)555WT | 555 W | 50.08 | 14.07 | 42.12 | 13.18 | ≈21.7% | 522 W | Mar 21, 2023 |
| GSP7G72M(H)560WT | 560 W | 50.24 | 14.14 | 42.28 | 13.25 | ≈21.9% | 527 W | Mar 21, 2023 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.352 %/°C |
| Voc coefficient β | −0.258 %/°C |
| Isc coefficient α | +0.029 %/°C |
| Operating cell temperature | NOCT 43.1 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 525 W | 391 W | 38.28 V × 10.21 A | 99.4 W | 95% |
| 530 W | 394.6 W | 38.43 V × 10.27 A | 100.3 W | 95% |
| 535 W | 398.3 W | 38.58 V × 10.33 A | 101.2 W | 95% |
| 540 W | 402 W | 38.73 V × 10.38 A | 102.2 W | 95% |
| 545 W | 405.8 W | 38.87 V × 10.44 A | 103.1 W | 95% |
| 550 W | 409.5 W | 39.02 V × 10.49 A | 104.1 W | 95% |
| 555 W | 413.3 W | 39.17 V × 10.55 A | 105 W | 95% |
| 560 W | 417 W | 39.32 V × 10.61 A | 106 W | 95% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 52.5 / 33.9 V | ✗ Not a match: module voltage below MPPT range | 1.42 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 52.5 / 33.9 V | ✓ Within range | 0.69 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 905 | 11,766 | 6.08 |
| Palmdale | 1,835 | 991 | 12,882 | 6.69 |
| Chula Vista | 1,696 | 916 | 11,906 | 6.11 |
| Huntington Beach | 1,643 | 887 | 11,534 | 5.89 |
| Riverside | 1,696 | 916 | 11,906 | 6.21 |
| Santa Clarita | 1,724 | 931 | 12,102 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| G-Star GSP7G72M(H)540WT | 540 W | ≈21.1% | −0.352 | 49.6 | 13.86 | — | — |
| JA Solar JAM72D30-540/MB | 540 W | ≈21.4% | −0.330 | 49.6 | 13.86 | product 2023, 2024 | 3 |
| Canadian Solar CS6W-540MB-AG | 540 W | ≈21% | −0.324 | 49.2 | 13.9 | product 2024 | 1 |
| LONGi LR5-72HBD-540M | 540 W | ≥21.1% | −0.354 | 49.5 | 13.85 | product 2026 | 1 |
Calculated from the panel area (2.56 m²): about 21.1% for the 540 W class. 540 W over 2.56 m² equals about 211 W per square meter.
PVWatts v8 with typical-year weather gives about 905 kWh per year per 540 W panel in Los Angeles and about 991 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.352 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.2% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.5 V, Vmp at 74 °C cell = 33.9 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.5 V vs max input 60 V; Vmp when hot 33.9 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.