Cali-GrafCali-Graf
Solar panelG-Star

G-Star GSP7F54M(H)400BB

108 cells. Power classes 390–415 W in the CEC list.

CEC listed · Mar 21, 2023UL 61730
Power class
  • Power (STC)400 WCEC nameplate
  • Efficiency≈20.5%calculated from area
  • %/°C Pmax−0.333CEC listing test
  • PTC / STC94.2%PTC 377 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
GSP7F54M(H)390BB390 W36.5013.6130.6512.73≈20.0%367 WMar 21, 2023
GSP7F54M(H)395BB395 W36.7513.6930.8512.81≈20.3%372 WMar 21, 2023
GSP7F54M(H)400BB400 W37.0013.7831.0512.89≈20.5%377 WMar 21, 2023
GSP7F54M(H)405BB405 W37.2513.8631.2412.97≈20.8%381 WMar 21, 2023
GSP7F54M(H)410BB410 W37.5013.9431.4313.05≈21.0%386 WMar 21, 2023
GSP7F54M(H)415BB415 W37.7514.0231.6413.13≈21.3%391 WMar 21, 2023
≈ efficiency = Pmax ÷ CEC-listed area 1.95 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.333 %/°C
Voc coefficient β−0.263 %/°C
Isc coefficient α+0.050 %/°C
Operating cell temperatureNOCT 43.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
390 W290.2 W28.25 V × 10.27 A73.5 W94%
395 W293.9 W28.43 V × 10.34 A74.4 W94%
400 W297.7 W28.61 V × 10.4 A75.4 W94%
405 W301.4 W28.79 V × 10.47 A76.3 W94%
410 W305.1 W28.96 V × 10.53 A77.2 W94%
415 W309 W29.16 V × 10.6 A78.2 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
39.2 V
Voc when cold
per panel
25.2 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–15
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–15
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–15
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V39.2 / 25.2 V⚠ Works; below MPPT at peak heat1.38
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V39.2 / 25.2 V✗ Not a match: module voltage below MPPT range1.05
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V39.2 / 25.2 V⚠ Works; below MPPT at peak heat0.51
Enphase IQ8M-72-2-US260–460 W60 V30–45 V39.2 / 25.2 V⚠ Works; below MPPT at peak heat1.23
Enphase IQ8A-72-2-US295–500 W60 V32–45 V39.2 / 25.2 V✗ Not a match: module voltage below MPPT range1.15
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67667012,0676.08
Palmdale1,83573413,2126.69
Chula Vista1,69667812,2116.11
Huntington Beach1,64365711,8305.89
Riverside1,69667812,2116.21
Santa Clarita1,72469012,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 400 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
G-Star GSP7F54M(H)400BB400 W≈20.5%−0.3333713.78——
Qcells Q.PEAK DUO BLK ML-G10+ 400400 W≥20.4%−0.36245.311.14product 2022, 2023221
JA Solar JAM54S31-400/MR400 W≈21.1%−0.32937.0713.79product 2023, 2024152
REC Group REC400AA Pure400 W≈22.3%−0.25648.810.25brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the G-Star GSP7F54M(H)400BB?

Calculated from the panel area (1.95 m²): about 20.5% for the 400 W class. 400 W over 1.95 m² equals about 205 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 670 kWh per year per 400 W panel in Los Angeles and about 734 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.333 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 39.2 V, Vmp at 74 °C cell = 25.2 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  4. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  6. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  7. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).