Cali-GrafCali-Graf
Solar panelG-Star

G-Star GSN8K66T(H)720WT

132 half-cut cells. Power classes 700–740 W in the CEC list.

CEC listed · Jun 11, 2026UL 61730
Power class
  • Power (STC)720 WCEC nameplate
  • Efficiency≈23.4%calculated from area
  • %/°C Pmax−0.292CEC listing test
  • PTC / STC95.2%PTC 685 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 9 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
GSN8K66T(H)700WT700 W48.6018.1040.1417.44≈22.7%666 WJun 11, 2026
GSN8K66T(H)705WT705 W48.7918.1440.3417.48≈22.9%671 WJun 11, 2026
GSN8K66T(H)710WT710 W48.9818.1840.5317.52≈23.1%676 WJun 11, 2026
GSN8K66T(H)715WT715 W49.1718.2240.7217.56≈23.2%680 WJun 11, 2026
GSN8K66T(H)720WT720 W49.3618.2640.9117.60≈23.4%685 WJun 11, 2026
GSN8K66T(H)725WT725 W49.5518.3041.1017.64≈23.5%690 WJun 11, 2026
GSN8K66T(H)730WT730 W49.7418.3441.2917.68≈23.7%695 WJun 11, 2026
GSN8K66T(H)735WT735 W49.9318.3841.4817.72≈23.9%700 WJun 11, 2026
GSN8K66T(H)740WT740 W50.1218.4241.6717.76≈24.0%705 WJun 11, 2026
≈ efficiency = Pmax ÷ CEC-listed area 3.08 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.292 %/°C
Voc coefficient β−0.243 %/°C
Isc coefficient α+0.043 %/°C
Operating cell temperatureNOCT 43.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
700 W534 W37.93 V × 14.08 A133.9 W96%
705 W537.9 W38.12 V × 14.11 A134.9 W96%
710 W541.7 W38.3 V × 14.14 A135.9 W96%
715 W545.5 W38.48 V × 14.18 A136.8 W96%
720 W549.2 W38.66 V × 14.21 A137.8 W96%
725 W553.1 W38.83 V × 14.24 A138.7 W96%
730 W556.9 W39.01 V × 14.27 A139.7 W96%
735 W560.7 W39.19 V × 14.31 A140.6 W96%
740 W564.5 W39.37 V × 14.34 A141.6 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.1 V
Voc when cold
per panel
34.2 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,20712,0676.08
Palmdale1,8351,32113,2126.69
Chula Vista1,6961,22112,2116.11
Huntington Beach1,6431,18311,8305.89
Riverside1,6961,22112,2116.21
Santa Clarita1,7241,24112,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 720 W panels

CEC PV Module List (Oct 7, 2026) · Canadian Solar datasheet · Kiwa PVEL Scorecard
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, A
G-Star GSN8K66T(H)720WT720 W≈23.4%−0.29249.3618.26
Canadian Solar CS7N-720TB-AG720 W≈23.2%−0.28548.718.69
Phono Solar PS720M13GFH-22/WNH720 W≈23.4%−0.29149.418.26
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the G-Star GSN8K66T(H)720WT?

Calculated from the panel area (3.08 m²): about 23.4% for the 720 W class. 720 W over 3.08 m² equals about 234 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,207 kWh per year per 720 W panel in Los Angeles and about 1,321 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.292 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.1 V, Vmp at 74 °C cell = 34.2 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet New N-type Bifacial Module TOPBiHiKu7 CS7N-725|730|735|740|745|750TB-AG.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  4. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  6. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  7. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).