132 half-cut cells, bifacial, glass (dual-glass module). Power classes 610–635 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| FST-G12R.132G-610 | 610 W | 48.38 | 15.63 | 41.24 | 15.04 | ≈22.8% | 579 W | Jan 12, 2026 |
| FST-G12R.132G-615 | 615 W | 48.50 | 15.62 | 41.35 | 14.89 | ≈22.9% | 584 W | Jan 12, 2026 |
| FST-G12R.132G-620 | 620 W | 48.61 | 15.65 | 41.45 | 14.98 | ≈23.1% | 588 W | Jan 12, 2026 |
| FST-G12R.132G-625 | 625 W | 48.72 | 15.68 | 41.55 | 15.07 | ≈23.3% | 593 W | Jan 12, 2026 |
| FST-G12R.132G-630 | 630 W | 48.83 | 15.71 | 41.63 | 15.16 | ≈23.5% | 598 W | Jan 12, 2026 |
| FST-G12R.132G-635 | 635 W | 48.95 | 15.74 | 41.74 | 15.24 | ≈23.7% | 603 W | Jan 12, 2026 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.295 %/°C |
| Voc coefficient β | −0.238 %/°C |
| Isc coefficient α | +0.037 %/°C |
| Operating cell temperature | NOCT 44 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 610 W | 462.5 W | 38.73 V × 11.94 A | 120.7 W | 99% |
| 615 W | 459.1 W | 38.83 V × 11.82 A | 119.8 W | 97% |
| 620 W | 463 W | 38.92 V × 11.9 A | 120.8 W | 97% |
| 625 W | 466.9 W | 39.02 V × 11.97 A | 121.8 W | 97% |
| 630 W | 470.6 W | 39.09 V × 12.04 A | 122.8 W | 97% |
| 635 W | 474.3 W | 39.2 V × 12.1 A | 123.8 W | 97% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 1,039 | 11,430 | 6.08 |
| Palmdale | 1,835 | 1,138 | 12,515 | 6.69 |
| Chula Vista | 1,696 | 1,052 | 11,567 | 6.11 |
| Huntington Beach | 1,643 | 1,019 | 11,205 | 5.89 |
| Riverside | 1,696 | 1,052 | 11,567 | 6.21 |
| Santa Clarita | 1,724 | 1,069 | 11,758 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) |
|---|---|---|---|---|---|---|
| FS GREEN ENERGIES FST-G12R.132G 620 | 620 W | ≈23.1% | −0.295 | 48.61 | 15.65 | — |
| ZNShine Solar ZXM7-UHLDD144-615/N | 615 W | ≈24% | −0.281 | 52.9 | 14.72 | product 2024, 2025, 2026 |
| JinkoSolar JKM620N-66HL4M-BDV | 620 W | ≈23% | −0.299 | 49.08 | 16.08 | product 2025 |
| Waaree BiN-21-620 | 620 W | ≥22.9% | −0.288 | 49.1 | 16.02 | product 2026 |
Calculated from the panel area (2.68 m²): about 23.1% for the 620 W class. 620 W over 2.68 m² equals about 231 W per square meter.
PVWatts v8 with typical-year weather gives about 1,039 kWh per year per 620 W panel in Los Angeles and about 1,138 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.295 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.3% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.3 V, Vmp at 74 °C cell = 34.7 V). Final design must follow the inverter manual and NEC 690.7.
Yes. Rear gain depends on mounting height and ground reflectance.