Cali-GrafCali-Graf
Solar panelFS GREEN ENERGIES

FS GREEN ENERGIES FST-G12R.132G 620

132 half-cut cells, bifacial, glass (dual-glass module). Power classes 610–635 W in the CEC list.

CEC listed · Jan 12, 2026UL 61730Bifacial
Power class
  • Power (STC)620 WCEC nameplate
  • Efficiency≈23.1%calculated from area
  • %/°C Pmax−0.295CEC listing test
  • PTC / STC94.9%PTC 588 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
FST-G12R.132G-610610 W48.3815.6341.2415.04≈22.8%579 WJan 12, 2026
FST-G12R.132G-615615 W48.5015.6241.3514.89≈22.9%584 WJan 12, 2026
FST-G12R.132G-620620 W48.6115.6541.4514.98≈23.1%588 WJan 12, 2026
FST-G12R.132G-625625 W48.7215.6841.5515.07≈23.3%593 WJan 12, 2026
FST-G12R.132G-630630 W48.8315.7141.6315.16≈23.5%598 WJan 12, 2026
FST-G12R.132G-635635 W48.9515.7441.7415.24≈23.7%603 WJan 12, 2026
≈ efficiency = Pmax ÷ CEC-listed area 2.68 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.295 %/°C
Voc coefficient β−0.238 %/°C
Isc coefficient α+0.037 %/°C
Operating cell temperatureNOCT 44 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
610 W462.5 W38.73 V × 11.94 A120.7 W99%
615 W459.1 W38.83 V × 11.82 A119.8 W97%
620 W463 W38.92 V × 11.9 A120.8 W97%
625 W466.9 W39.02 V × 11.97 A121.8 W97%
630 W470.6 W39.09 V × 12.04 A122.8 W97%
635 W474.3 W39.2 V × 12.1 A123.8 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
51.3 V
Voc when cold
per panel
34.7 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,03911,4306.08
Palmdale1,8351,13812,5156.69
Chula Vista1,6961,05211,5676.11
Huntington Beach1,6431,01911,2055.89
Riverside1,6961,05211,5676.21
Santa Clarita1,7241,06911,7586.28
746Jan747Feb958Mar1,058Apr1,046May1,111Jun1,170Jul1,184Aug1,035Sep913Oct785Nov679DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 620 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
FS GREEN ENERGIES FST-G12R.132G 620620 W≈23.1%−0.29548.6115.65—
ZNShine Solar ZXM7-UHLDD144-615/N615 W≈24%−0.28152.914.72product 2024, 2025, 2026
JinkoSolar JKM620N-66HL4M-BDV620 W≈23%−0.29949.0816.08product 2025
Waaree BiN-21-620620 W≥22.9%−0.28849.116.02product 2026
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the FS GREEN ENERGIES FST-G12R.132G 620?

Calculated from the panel area (2.68 m²): about 23.1% for the 620 W class. 620 W over 2.68 m² equals about 231 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,039 kWh per year per 620 W panel in Los Angeles and about 1,138 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.295 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.3% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.3 V, Vmp at 74 °C cell = 34.7 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR PRODUCT.
  3. Waaree — datasheet ELITE-R-SERIES-BiN-21-600-635-WEL-EPD-600-635-132-BiN-HC.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).