Cali-GrafCali-Graf
Solar panelFirst Solar

First Solar FS-6430-P-I

264 cells. Power classes 400–460 W in the CEC list.

CEC listed · Oct 3, 2022UL 61730PVEL Top Performer 2023
Power class
  • Power (STC)430 WCEC nameplate
  • Efficiency≈17.1%calculated from area
  • %/°C Pmax−0.279CEC listing test
  • PTC / STC93.7%PTC 403 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 13 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
FS-6400-P-I400 W216.102.51176.102.27≈15.9%374 WOct 3, 2022
FS-6405-P-I405 W216.802.52177.202.29≈16.1%379 WOct 3, 2022
FS-6410-P-I410 W217.402.52178.302.30≈16.3%384 WOct 3, 2022
FS-6415-P-I415 W218.102.53179.302.31≈16.5%388 WOct 3, 2022
FS-6420-P-I420 W218.102.53179.302.31≈16.7%393 WOct 3, 2022
FS-6425-P-I425 W218.902.54181.502.34≈16.9%398 WOct 3, 2022
FS-6430-P-I430 W219.202.54182.602.36≈17.1%403 WOct 3, 2022
FS-6435-P-I435 W219.602.55183.602.37≈17.3%408 WOct 3, 2022
FS-6440-P-I440 W220.002.56184.702.38≈17.5%412 WOct 3, 2022
FS-6445-P-I445 W220.402.56185.702.40≈17.7%417 WOct 3, 2022
FS-6450-P-I450 W221.102.57186.802.41≈17.9%422 WOct 3, 2022
FS-6455-P-I455 W222.002.58187.802.42≈18.1%427 WOct 3, 2022
FS-6460-P-I460 W222.902.59188.802.44≈18.3%432 WOct 3, 2022
≈ efficiency = Pmax ÷ CEC-listed area 2.52 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.279 %/°C
Voc coefficient β−0.271 %/°C
Isc coefficient α+0.053 %/°C
Operating cell temperatureNOCT 47.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
400 W317.9 W167.74 V × 1.9 A81.8 W102%
405 W322.7 W168.79 V × 1.91 A83.1 W103%
410 W326.1 W169.83 V × 1.92 A83.9 W102%
415 W329.4 W170.79 V × 1.93 A84.8 W102%
420 W329.4 W170.79 V × 1.93 A84.8 W101%
425 W337.7 W172.88 V × 1.95 A86.9 W102%
430 W342.7 W173.93 V × 1.97 A88.2 W103%
435 W346 W174.88 V × 1.98 A89.1 W102%
440 W349.6 W175.93 V × 1.99 A90 W102%
445 W354.4 W176.88 V × 2 A91.2 W103%
450 W358 W177.93 V × 2.01 A92.2 W102%
455 W361.4 W178.88 V × 2.02 A93 W102%
460 W366.3 W179.84 V × 2.04 A94.3 W103%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard
2023
PVEL Top Performer
this series
5
Tests passed as Top Performer
DH, LID+LETID, MSS, PID, TC
5
PVEL Scorecards
First Solar named Top Performer, 2018–2023

PVEL Top Performer tests

YearProductTests
2023FS-6xxx-P-IDHLID+LETIDMSSPIDTC

Tested bill of materials

Details describe the tested sample, not every module of the series.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
232.9 V
Voc when cold
per panel
152.9 V
Vmp when hot
per panel
2
Max panels / string
max DC 600 V
1
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet1–2
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet1–2
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet1–2
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window2–2

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V232.9 / 152.9 V✗ Not allowed: cold Voc above max input1.48
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V232.9 / 152.9 V✗ Not allowed: cold Voc above max input1.13
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V232.9 / 152.9 V✗ Not allowed: cold Voc above max input0.55
Enphase IQ8M-72-2-US260–460 W60 V30–45 V232.9 / 152.9 V✗ Not allowed: cold Voc above max input1.32
Enphase IQ8A-72-2-US295–500 W60 V32–45 V232.9 / 152.9 V✗ Not allowed: cold Voc above max input1.23
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67672111,5316.08
Palmdale1,83578912,6256.69
Chula Vista1,69672911,6686.11
Huntington Beach1,64370611,3045.89
Riverside1,69672911,6686.21
Santa Clarita1,72474111,8616.28
753Jan753Feb967Mar1,068Apr1,055May1,121Jun1,181Jul1,194Aug1,044Sep921Oct792Nov685DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

About First Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard

Other series by SoCal permits

FS-6xxx-P-BFS-6xxx-P-B-2FS-6xxxA-P-BFS-6xxxA-P-B-2FS-7xxxA-FT1FS-7xxxA-TR1

Questions & answers

How efficient is the First Solar FS-6430-P-I?

Calculated from the panel area (2.52 m²): about 17.1% for the 430 W class. 430 W over 2.52 m² equals about 171 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 721 kWh per year per 430 W panel in Los Angeles and about 789 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.279 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 14.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 1–2 panels per string (Voc at 2 °C = 232.9 V, Vmp at 74 °C cell = 152.9 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

FS-6xxx-P-I was a PVEL Top Performer in 2023 (DH, LID+LETID, MSS, PID, TC).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2018–2023.
  3. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  4. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  5. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).