CEC PV Module List (Oct 7, 2026) · NLR SAM inverter library · Cali-Graf calculation
DC module insideLR6-60PB-300M
MicroinverterIQ7-60-ACM-US
Microinverter AC output240 W ACNLR SAM inverter library
DC/AC ratio1.25Pmax ÷ microinverter AC rating
The string calculator does not apply: each panel has its own microinverter, wired as AC branch circuits.
Build & dimensions
CEC PV Module List (Oct 7, 2026)
Module area1.58 m² (17 ft²)CEC-listed area
Cells60 cells
Back coverBlack backsheet
Heat & cold behaviour
CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ
−0.391 %/°C
Voc coefficient β
−0.284 %/°C
Isc coefficient α
+0.036 %/°C
Operating cell temperature
NOCT 48.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.
Away from lab conditions — CEC listing test points
Class
Pmax at NOCT
Vmp × Imp at NOCT
Pmax at 200 W/m²
Low-light efficiency vs STC
300 W
219.2 W
29.91 V × 7.33 A
58.7 W
98%
305 W
217.7 W
30.25 V × 7.2 A
57.6 W
94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
503
11,564
6.08
Palmdale
1,835
550
12,662
6.69
Chula Vista
1,696
509
11,702
6.11
Huntington Beach
1,643
493
11,337
5.89
Riverside
1,696
509
11,702
6.21
Santa Clarita
1,724
517
11,896
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Questions & answers
How efficient is the Enphase Energy XACM-IQ7-LR6-60PB-300M?
Calculated from the panel area (1.58 m²): about 19% for the 300 W class. 300 W over 1.58 m² equals about 190 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 503 kWh per year per 300 W panel in Los Angeles and about 550 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.391 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.3% below the STC rating.
What microinverter is built into the Enphase Energy XACM-IQ7-LR6-60PB-300M?
The CEC listing names IQ7-60-ACM-US paired with the LR6-60PB-300M DC module; the microinverter is rated 240 W AC.
Sources
California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).