Cali-GrafCali-Graf
Solar panelEMMVEE Photovoltaic Power

EMMVEE Photovoltaic Power E670HCBG132-T

132 half-cut cells, bifacial. Power classes 595–715 W in the CEC list.

CEC listed · Jul 13, 2026UL 61730BifacialPVEL Top Performer 2025, 2026
Power class
  • Power (STC)670 WCEC nameplate
  • Efficiency≈21.5%calculated from area
  • %/°C Pmax−0.289CEC listing test
  • PTC / STC94.3%PTC 632 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 19 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
E595HCBG132-T595 W48.4215.6640.1914.82≈22.0%562 WJul 13, 2026
E600HCBG132-T600 W48.5715.7440.3314.90≈22.2%567 WJul 13, 2026
E605HCBG132-T605 W48.7215.8140.4614.98≈22.4%572 WJul 13, 2026
E610HCBG132-T610 W48.8815.8640.5915.05≈22.6%577 WJul 13, 2026
E615HCBG132-T615 W49.0115.9640.6915.13≈22.8%582 WJul 13, 2026
E620HCBG132-T620 W49.1416.0440.8215.19≈23.0%586 WJul 13, 2026
E625HCBG132-T625 W49.3016.1140.9515.27≈23.1%591 WJul 13, 2026
E630HCBG132-T630 W49.4316.1941.0515.35≈23.3%596 WJul 13, 2026
E635HCBG132-T635 W49.5616.2041.1815.42≈23.5%601 WJul 13, 2026
E670HCBG132-T670 W47.2118.3539.2217.09≈21.5%632 WJul 13, 2026
E675HCBG132-T675 W47.3418.3839.3417.17≈21.7%637 WJul 13, 2026
E680HCBG132-T680 W47.4818.4039.4517.25≈21.9%642 WJul 13, 2026
E685HCBG132-T685 W47.6218.4239.5617.33≈22.0%647 WJul 13, 2026
E690HCBG132-T690 W47.7618.4439.6817.41≈22.2%651 WJul 13, 2026
E695HCBG132-T695 W47.9018.4639.8017.48≈22.3%656 WJul 13, 2026
E700HCBG132-T700 W48.0418.4839.9117.55≈22.5%661 WJul 13, 2026
E705HCBG132-T705 W48.1818.5040.0417.62≈22.7%666 WJul 13, 2026
E710HCBG132-T710 W48.3218.5240.1317.70≈22.8%671 WJul 13, 2026
E715HCBG132-T715 W48.4618.5440.2517.77≈23.0%676 WJul 13, 2026
≈ efficiency = Pmax ÷ CEC-listed area 2.7 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.289 %/°C
Voc coefficient β−0.228 %/°C
Isc coefficient α+0.040 %/°C
Operating cell temperatureNOCT 45.9 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
595 W452.3 W37.49 V × 12.06 A118.4 W99%
600 W456.3 W37.62 V × 12.13 A119.5 W100%
605 W460.2 W37.74 V × 12.19 A120.5 W100%
610 W463.9 W37.86 V × 12.25 A121.4 W100%
615 W467.5 W37.96 V × 12.32 A122.4 W100%
620 W470.8 W38.08 V × 12.36 A123.3 W99%
625 W474.8 W38.2 V × 12.43 A124.3 W99%
630 W478.5 W38.29 V × 12.5 A125.3 W99%
635 W482.2 W38.41 V × 12.55 A126.2 W99%
670 W490.4 W36.85 V × 13.31 A134.6 W100%
675 W494.2 W36.97 V × 13.37 A135.7 W101%
680 W497.9 W37.07 V × 13.43 A136.7 W101%
685 W501.6 W37.17 V × 13.49 A137.7 W101%
690 W505.4 W37.29 V × 13.55 A138.8 W101%
695 W509 W37.4 V × 13.61 A139.8 W101%
700 W512.4 W37.5 V × 13.66 A140.7 W100%
705 W516.1 W37.63 V × 13.72 A141.7 W101%
710 W519.6 W37.71 V × 13.78 A142.7 W100%
715 W523.3 W37.82 V × 13.83 A143.7 W100%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard
2025, 2026
PVEL Top Performer
this series
6
Tests passed as Top Performer
DH, HSS, LID+LETID, MSS, PID, TC
4
PVEL Scorecards
EMMVEE Photovoltaic Power named Top Performer, 2023–2026

PVEL Top Performer tests

YearProductTests
2025ExxxHCBG132-THSSLID+LETIDMSSPID
2026ExxxHCBG132-TDHLID+LETIDMSSPIDTC

Tested bill of materials

Details describe the tested sample, not every module of the series.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
49.7 V
Voc when cold
per panel
32.9 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,12311,2296.08
Palmdale1,8351,22912,2946.69
Chula Vista1,6961,13611,3636.11
Huntington Beach1,6431,10111,0085.89
Riverside1,6961,13611,3636.21
Santa Clarita1,7241,15511,5516.28
733Jan734Feb941Mar1,040Apr1,027May1,091Jun1,150Jul1,163Aug1,017Sep897Oct771Nov667DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

About EMMVEE Photovoltaic Power

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard

Other series by SoCal permits

ExxxHCBG144-TExxxHCBT144-TExxxHCM120-BTExxxHCMW144-TExxxHCBG144ExxxHCM120-B

Questions & answers

How efficient is the EMMVEE Photovoltaic Power E670HCBG132-T?

Calculated from the panel area (3.11 m²): about 21.5% for the 670 W class. 670 W over 3.11 m² equals about 215 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,123 kWh per year per 670 W panel in Los Angeles and about 1,229 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.289 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 49.7 V, Vmp at 74 °C cell = 32.9 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

ExxxHCBG132-T was a PVEL Top Performer in 2025, 2026 (DH, HSS, LID+LETID, MSS, PID, TC).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2023–2026.
  3. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  4. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  5. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).