Cali-GrafCali-Graf
Solar panelELITE Solar

ELITE Solar ET-N778TBH635GB

156 half-cut cells, bifacial, glass (dual-glass module). Power classes 615–660 W in the CEC list.

CEC listed · Jul 1, 2025UL 61730Bifacial
Power class
  • Power (STC)635 WCEC nameplate
  • Efficiency≈22.7%calculated from area
  • %/°C Pmax−0.297CEC listing test
  • PTC / STC95%PTC 603 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
ET-N778TBH615GB615 W55.8913.5947.9412.83≈22.0%584 WJul 1, 2025
ET-N778TBH620GB620 W56.0913.6448.1212.89≈22.1%589 WJul 1, 2025
ET-N778TBH625GB625 W56.2913.6948.2712.95≈22.3%593 WJul 1, 2025
ET-N778TBH630GB630 W56.4913.7448.4313.01≈22.5%598 WJul 1, 2025
ET-N778TBH635GB635 W56.6913.7948.5913.07≈22.7%603 WJul 1, 2025
ET-N778TBH640GB640 W56.8913.8448.7513.13≈22.9%608 WJul 1, 2025
ET-N778TBH645GB645 W57.0913.8948.9113.19≈23.0%613 WJul 1, 2025
ET-N778TBH650GB650 W57.2913.9349.0713.25≈23.2%618 WJul 1, 2025
ET-N778TBH655GB655 W57.4913.9849.2213.31≈23.4%623 WJul 1, 2025
ET-N778TBH660GB660 W57.6914.0349.3713.37≈23.6%627 WJul 1, 2025
≈ efficiency = Pmax ÷ CEC-listed area 2.8 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.297 %/°C
Voc coefficient β−0.221 %/°C
Isc coefficient α+0.044 %/°C
Operating cell temperatureNOCT 43.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
615 W465 W45.56 V × 10.21 A117 W95%
620 W468.9 W45.73 V × 10.26 A118 W95%
625 W472.6 W45.87 V × 10.3 A119 W95%
630 W476.4 W46.02 V × 10.35 A119.9 W95%
635 W480.1 W46.17 V × 10.4 A120.9 W95%
640 W483.9 W46.33 V × 10.45 A121.8 W95%
645 W487.7 W46.48 V × 10.49 A122.8 W95%
650 W491.5 W46.63 V × 10.54 A123.7 W95%
655 W495.3 W46.77 V × 10.59 A124.7 W95%
660 W499 W46.92 V × 10.64 A125.6 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard
6
PVEL Scorecards
ELITE Solar named Top Performer, 2021–2026
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
59.6 V
Voc when cold
per panel
40.5 V
Vmp when hot
per panel
10
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–10
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet2–10
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–10
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window6–8

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,06411,7076.08
Palmdale1,8351,16512,8176.69
Chula Vista1,6961,07711,8476.11
Huntington Beach1,6431,04311,4765.89
Riverside1,6961,07711,8476.21
Santa Clarita1,7241,09512,0426.28
764Jan765Feb981Mar1,084Apr1,071May1,138Jun1,199Jul1,213Aug1,060Sep935Oct804Nov696DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 635 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
ELITE Solar ET-N778TBH635GB635 W≈22.7%−0.29756.6913.79brand 6×
Canadian Solar CS7N-635MB-AG635 W≈20.7%−0.39044.418.27product 2024
Waaree BiN-02-635635 W≥22.4%−0.29543.7418.3brand 5× (2022–2026)
Hyundai Energy Solutions HiS-T635NJ635 W≈23%−0.29457.5613.98brand 5× (2017–2025)
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the ELITE Solar ET-N778TBH635GB?

Calculated from the panel area (2.8 m²): about 22.7% for the 635 W class. 635 W over 2.8 m² equals about 227 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,064 kWh per year per 635 W panel in Los Angeles and about 1,165 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.297 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 59.6 V, Vmp at 74 °C cell = 40.5 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; ELITE Solar was named a Top Performer in 6 Scorecards (2021–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Waaree — datasheet ELITE SERIES BiN-02.
  3. Hyundai Energy Solutions — datasheet [US] NJ(HiS) Series (N TOPCon Bifacial) 635~645W.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2021–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).