144 half-cut cells, bifacial, glass (dual-glass module). Power classes 560–610 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| ET-N772TBH560GL | 560 W | 51.28 | 13.52 | 44.03 | 12.72 | ≈21.7% | 530 W | May 21, 2024 |
| ET-N772TBH565GL | 565 W | 51.48 | 13.57 | 44.21 | 12.78 | ≈21.9% | 535 W | May 21, 2024 |
| ET-N772TBH570GL | 570 W | 51.68 | 13.62 | 44.38 | 12.85 | ≈22.1% | 540 W | May 21, 2024 |
| ET-N772TBH575GL | 575 W | 51.88 | 13.67 | 44.55 | 12.91 | ≈22.3% | 545 W | May 21, 2024 |
| ET-N772TBH580GL | 580 W | 52.08 | 13.72 | 44.72 | 12.97 | ≈22.5% | 550 W | May 21, 2024 |
| ET-N772TBH585GL | 585 W | 52.28 | 13.76 | 44.90 | 13.03 | ≈22.7% | 554 W | May 21, 2024 |
| ET-N772TBH590GL | 590 W | 52.48 | 13.81 | 45.08 | 13.09 | ≈22.9% | 559 W | May 21, 2024 |
| ET-N772TBH595GL | 595 W | 52.68 | 13.86 | 45.25 | 13.15 | ≈23.1% | 565 W | May 21, 2024 |
| ET-N772TBH600GL | 600 W | 52.88 | 13.90 | 45.42 | 13.21 | ≈23.3% | 570 W | Jul 1, 2025 |
| ET-N772TBH605GL | 605 W | 53.08 | 13.95 | 45.59 | 13.27 | ≈23.4% | 575 W | Jul 1, 2025 |
| ET-N772TBH610GL | 610 W | 53.28 | 14.00 | 45.77 | 13.33 | ≈23.6% | 580 W | Jul 1, 2025 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.306 %/°C |
| Voc coefficient β | −0.227 %/°C |
| Isc coefficient α | +0.044 %/°C |
| Operating cell temperature | NOCT 43.6 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 560 W | 424.1 W | 42.02 V × 10.09 A | 106.6 W | 95% |
| 565 W | 427.8 W | 42.19 V × 10.14 A | 107.5 W | 95% |
| 570 W | 431.8 W | 42.35 V × 10.19 A | 108.5 W | 95% |
| 575 W | 435.5 W | 42.52 V × 10.24 A | 109.4 W | 95% |
| 580 W | 439.2 W | 42.68 V × 10.29 A | 110.4 W | 95% |
| 585 W | 443 W | 42.85 V × 10.34 A | 111.3 W | 95% |
| 590 W | 446.8 W | 43.02 V × 10.39 A | 112.3 W | 95% |
| 595 W | 448.8 W | 42.74 V × 10.5 A | 114.5 W | 96% |
| 600 W | 448.8 W | 42.74 V × 10.5 A | 114.5 W | 95% |
| 605 W | 452.5 W | 42.9 V × 10.55 A | 115.5 W | 95% |
| 610 W | 456.4 W | 43.07 V × 10.6 A | 116.5 W | 95% |
| Year | Product | Tests |
|---|---|---|
| 2025 | ET-N772TBHxxxGL | DHLID+LETIDMSSTC |
| 2024 | ET-N772TBHxxxGL/GB (closely related product name) | LID+LETIDMSSPANTC |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–10 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–10 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–10 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 980 | 11,766 | 6.08 |
| Palmdale | 1,835 | 1,073 | 12,882 | 6.69 |
| Chula Vista | 1,696 | 992 | 11,906 | 6.11 |
| Huntington Beach | 1,643 | 961 | 11,534 | 5.89 |
| Riverside | 1,696 | 992 | 11,906 | 6.21 |
| Santa Clarita | 1,724 | 1,009 | 12,102 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| ELITE Solar ET-N772TBH585GL | 585 W | ≈22.7% | −0.306 | 52.28 | 13.76 | product 2025 | — |
| VSUN (Vietnam Sunergy) VSUN585N-144MH | 585 W | ≈22.7% | −0.309 | 52.25 | 13.88 | brand 6× (2021–2026) | 1 |
| Phono Solar PS585M8GFH-24/TNH | 585 W | ≈22.9% | −0.293 | 52.9 | 13.72 | product 2024, 2025 | 1 |
| Qcells Q.PEAK DUO XL-G11S.3/BFG 585 | 585 W | ≈21.5% | −0.348 | 53.57 | 13.72 | product 2024, 2025, 2026 | 1 |
Calculated from the panel area (2.58 m²): about 22.7% for the 585 W class. 585 W over 2.58 m² equals about 227 W per square meter.
PVWatts v8 with typical-year weather gives about 980 kWh per year per 585 W panel in Los Angeles and about 1,073 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.306 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.9% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 55 V, Vmp at 74 °C cell = 37.2 V). Final design must follow the inverter manual and NEC 690.7.
Yes. Rear gain depends on mounting height and ground reflectance.
ET-N772TBHxxxGL was a PVEL Top Performer in 2025 (DH, LID+LETID, MSS, TC).