ELITE Solar ET-N754TBH435GL

108 half-cut cells, bifacial, glass (dual-glass module). Power classes 415–455 W in the CEC list.

CEC listed · May 21, 2024UL 61730BifacialPVEL Top Performer 2025
Power class
  • Power (STC)435 WCEC nameplate
  • Efficiency≈22.3%calculated from area
  • %/°C Pmax−0.306CEC listing test
  • PTC / STC94.7%PTC 412 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 9 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
ET-N754TBH415GL415 W38.2613.4532.8412.64≈21.3%393 WMay 21, 2024
ET-N754TBH420GL420 W38.4613.5233.0212.72≈21.5%398 WMay 21, 2024
ET-N754TBH425GL425 W38.6613.5833.2112.80≈21.8%402 WMay 21, 2024
ET-N754TBH430GL430 W38.8613.6533.3912.88≈22.1%407 WMay 21, 2024
ET-N754TBH435GL435 W39.0613.7233.5512.97≈22.3%412 WMay 21, 2024
ET-N754TBH440GL440 W39.2613.7833.7313.05≈22.6%417 WMay 21, 2024
ET-N754TBH445GL445 W39.4613.8433.9013.13≈22.8%422 WMay 21, 2024
ET-N754TBH450GL450 W39.6613.9034.0813.21≈23.1%428 WJul 1, 2025
ET-N754TBH455GL455 W39.8613.9734.2413.29≈23.3%432 WJul 1, 2025
≈ efficiency = Pmax ÷ CEC-listed area 1.95 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.306 %/°C
Voc coefficient β−0.227 %/°C
Isc coefficient α+0.044 %/°C
Operating cell temperatureNOCT 43.6 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
415 W308.5 W30.78 V × 10.02 A77.8 W94%
420 W312.1 W30.95 V × 10.09 A78.7 W94%
425 W315.9 W31.13 V × 10.15 A79.7 W94%
430 W319.6 W31.29 V × 10.21 A80.6 W94%
435 W323.4 W31.44 V × 10.28 A81.5 W94%
440 W327.1 W31.61 V × 10.35 A82.5 W94%
445 W330.8 W31.77 V × 10.41 A83.4 W94%
450 W329.6 W32 V × 10.3 A82.9 W92%
455 W333.1 W32.15 V × 10.36 A83.8 W92%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard
2024, 2025
PVEL Top Performer
this series
4
Tests passed as Top Performer
DH, LID+LETID, MSS, TC
6
PVEL Scorecards
ELITE Solar named Top Performer, 2021–2026

PVEL Top Performer tests

YearProductTests
2025ET-N754TBHxxxGLDHLID+LETIDMSSTC
2024ET-N754TBHxxxGL/GB (closely related product name)LID+LETIDMSSTC

Tested bill of materials

Details describe the tested sample, not every module of the series.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
41.1 V
Voc when cold
per panel
27.8 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V41.1 / 27.8 V⚠ Works; below MPPT at peak heat1.5
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V41.1 / 27.8 V✗ Not a match: module voltage below MPPT range1.14
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V41.1 / 27.8 V⚠ Works; below MPPT at peak heat0.56
Enphase IQ8M-72-2-US260–460 W60 V30–45 V41.1 / 27.8 V⚠ Works; below MPPT at peak heat1.34
Enphase IQ8A-72-2-US295–500 W60 V32–45 V41.1 / 27.8 V⚠ Works; below MPPT at peak heat1.25
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67672911,6656.08
Palmdale1,83579812,7726.69
Chula Vista1,69673811,8046.11
Huntington Beach1,64371511,4355.89
Riverside1,69673811,8046.21
Santa Clarita1,72475011,9996.28
761Jan762Feb978Mar1,080Apr1,067May1,134Jun1,194Jul1,208Aug1,057Sep932Oct801Nov693DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 435 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
ELITE Solar ET-N754TBH435GL435 W≈22.3%−0.30639.0613.72—product 2025—
Canadian Solar CS3N-430MS430 W≈21.8%−0.33245.711.8625 yrproduct 202346
Qcells Q.TRON BLK M-G2+ 435435 W≥22.3%−0.27639.613.8225 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-435QD435 W≈22.3%−0.29438.9414.0525 / 30 yrbrand 7× (2017–2025)39
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the ELITE Solar ET-N754TBH435GL?

Calculated from the panel area (1.95 m²): about 22.3% for the 435 W class. 435 W over 1.95 m² equals about 223 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 729 kWh per year per 435 W panel in Los Angeles and about 798 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.306 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.9% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 41.1 V, Vmp at 74 °C cell = 27.8 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

ET-N754TBHxxxGL was a PVEL Top Performer in 2025 (DH, LID+LETID, MSS, TC).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  3. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  4. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2021–2026.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).