144 half-cut cells, bifacial, transparent backsheet. Power classes 530–570 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| ELNSM72M-HC-BF-530 | 530 W | 49.30 | 13.61 | 41.05 | 12.20 | ≈20.7% | 500 W | Apr 11, 2025 |
| ELNSM72M-HC-BF-535 | 535 W | 49.40 | 13.71 | 41.30 | 12.60 | ≈20.9% | 505 W | Apr 11, 2025 |
| ELNSM72M-HC-BF-540 | 540 W | 49.50 | 13.81 | 41.55 | 13.00 | ≈21.1% | 510 W | Apr 11, 2025 |
| ELNSM72M-HC-BF-545 | 545 W | 49.60 | 13.90 | 41.80 | 13.04 | ≈21.3% | 515 W | Apr 11, 2025 |
| ELNSM72M-HC-BF-550 | 550 W | 49.70 | 14.00 | 42.05 | 13.08 | ≈21.5% | 520 W | Apr 11, 2025 |
| ELNSM72M-HC-BF-555 | 555 W | 49.80 | 14.10 | 42.31 | 13.12 | ≈21.7% | 524 W | Apr 11, 2025 |
| ELNSM72M-HC-BF-560 | 560 W | 49.90 | 14.20 | 42.56 | 13.16 | ≈21.9% | 529 W | Apr 11, 2025 |
| ELNSM72M-HC-BF-565 | 565 W | 50.00 | 14.30 | 42.81 | 13.20 | ≈22.1% | 534 W | Apr 11, 2025 |
| ELNSM72M-HC-BF-570 | 570 W | 50.10 | 14.40 | 43.06 | 13.24 | ≈22.3% | 539 W | Apr 11, 2025 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.325 %/°C |
| Voc coefficient β | −0.242 %/°C |
| Isc coefficient α | +0.042 %/°C |
| Operating cell temperature | NOCT 43.2 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 530 W | 377.8 W | 38.11 V × 9.91 A | 95 W | 90% |
| 535 W | 392.6 W | 38.34 V × 10.24 A | 98.7 W | 92% |
| 540 W | 407.5 W | 38.57 V × 10.56 A | 102.4 W | 95% |
| 545 W | 411.2 W | 38.8 V × 10.6 A | 103.4 W | 95% |
| 550 W | 414.9 W | 39.03 V × 10.63 A | 104.3 W | 95% |
| 555 W | 418.8 W | 39.28 V × 10.66 A | 105.3 W | 95% |
| 560 W | 422.5 W | 39.51 V × 10.7 A | 106.2 W | 95% |
| 565 W | 426.3 W | 39.74 V × 10.73 A | 107.2 W | 95% |
| 570 W | 430.1 W | 39.97 V × 10.76 A | 108.1 W | 95% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 52.5 / 34.5 V | ✓ Within range | 0.71 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 922 | 11,983 | 6.08 |
| Palmdale | 1,835 | 1,009 | 13,120 | 6.69 |
| Chula Vista | 1,696 | 933 | 12,126 | 6.11 |
| Huntington Beach | 1,643 | 904 | 11,747 | 5.89 |
| Riverside | 1,696 | 933 | 12,126 | 6.21 |
| Santa Clarita | 1,724 | 948 | 12,327 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Elin Energy (Sirius PV) ELNSM72M-HC-BF 550 | 550 W | ≈21.5% | −0.325 | 49.7 | 14 | — | — |
| JA Solar JAM72D30-550/MB | 550 W | ≈21.8% | −0.330 | 49.9 | 14 | product 2023, 2024 | 3 |
| LONGi LR5-72HBD-550M | 550 W | ≥21.5% | −0.354 | 49.8 | 13.99 | product 2026 | 1 |
| Canadian Solar CS6W-550MB-AG | 550 W | ≈21.4% | −0.324 | 49.6 | 14 | product 2024 | 1 |
Calculated from the panel area (2.56 m²): about 21.5% for the 550 W class. 550 W over 2.56 m² equals about 215 W per square meter.
PVWatts v8 with typical-year weather gives about 922 kWh per year per 550 W panel in Los Angeles and about 1,009 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.325 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.8% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.5 V, Vmp at 74 °C cell = 34.5 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.5 V vs max input 60 V; Vmp when hot 34.5 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.