Cali-GrafCali-Graf
Solar panelElin Energy (Sirius PV)

Elin Energy (Sirius PV) ELNSM66M-HC-BF 505

132 half-cut cells, bifacial, transparent backsheet. Power classes 490–525 W in the CEC list.

CEC listed · Apr 11, 2025UL 61730Bifacial
Power class
  • Power (STC)505 WCEC nameplate
  • Efficiency≈21.4%calculated from area
  • %/°C Pmax−0.325CEC listing test
  • PTC / STC94.5%PTC 477 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
ELNSM66M-HC-BF-490490 W45.2513.8037.2313.16≈20.8%462 WApr 11, 2025
ELNSM66M-HC-BF-495495 W45.4513.8537.3913.24≈21.0%467 WApr 11, 2025
ELNSM66M-HC-BF-500500 W45.6513.9037.5513.32≈21.2%472 WApr 11, 2025
ELNSM66M-HC-BF-505505 W45.8513.9537.7113.39≈21.4%477 WApr 11, 2025
ELNSM66M-HC-BF-510510 W46.0514.0037.8713.47≈21.7%482 WApr 11, 2025
ELNSM66M-HC-BF-515515 W46.2514.0538.0313.55≈21.9%487 WApr 11, 2025
ELNSM66M-HC-BF-520520 W46.4514.1038.1913.63≈22.1%492 WApr 11, 2025
ELNSM66M-HC-BF-525525 W46.6514.1538.3513.71≈22.3%496 WApr 11, 2025
≈ efficiency = Pmax ÷ CEC-listed area 2.36 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.325 %/°C
Voc coefficient β−0.242 %/°C
Isc coefficient α+0.042 %/°C
Operating cell temperatureNOCT 43.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
490 W369.8 W34.54 V × 10.7 A93.1 W95%
495 W373.6 W34.69 V × 10.77 A94.1 W95%
500 W377.5 W34.84 V × 10.83 A95.1 W95%
505 W381.1 W34.99 V × 10.89 A96 W95%
510 W385 W35.14 V × 10.96 A97 W95%
515 W388.9 W35.29 V × 11.02 A98 W95%
520 W392.9 W35.43 V × 11.09 A98.9 W95%
525 W396.8 W35.58 V × 11.15 A99.9 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
48.4 V
Voc when cold
per panel
30.9 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V48.4 / 30.9 V✗ Not a match: module voltage below MPPT range1.33
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V48.4 / 30.9 V✓ Within range0.65
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67684611,8496.08
Palmdale1,83592712,9736.69
Chula Vista1,69685611,9916.11
Huntington Beach1,64383011,6165.89
Riverside1,69685611,9916.21
Santa Clarita1,72487112,1896.28
773Jan774Feb993Mar1,097Apr1,084May1,152Jun1,213Jul1,227Aug1,073Sep947Oct814Nov704DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 505 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASoCal permits (series)
Elin Energy (Sirius PV) ELNSM66M-HC-BF 505505 W≈21.4%−0.32545.8513.95—
SEG Solar SEG-505-BTD-BG505 W≈25.9%−0.29040.315.958
Qcells Q.PEAK DUO XL-G10.d 505505 W≈21.8%−0.34053.7811.396
AXITEC AC-530MH/144V530 W≥20.5%−0.36649.313.721
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Elin Energy (Sirius PV) ELNSM66M-HC-BF 505?

Calculated from the panel area (2.36 m²): about 21.4% for the 505 W class. 505 W over 2.36 m² equals about 214 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 846 kWh per year per 505 W panel in Los Angeles and about 927 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.325 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.8% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 48.4 V, Vmp at 74 °C cell = 30.9 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 48.4 V vs max input 60 V; Vmp when hot 30.9 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO XL-G10.d ENDURING HIGH PERFORMANCE”.
  4. AXITEC — datasheet AXIworldbipremium bifacial 144 cells asemmbled in US.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).