Solar panelElin Energy (Sirius PV)

Elin Energy (Sirius PV) ELNSM54M-HC-LV-N 440

108 half-cut cells. Power classes 415–465 W in the CEC list.

CEC listed · Aug 21, 2025UL 61730
Power class
  • Power (STC)440 WCEC nameplate
  • Efficiency≈22.7%calculated from area
  • %/°C Pmax−0.292CEC listing test
  • PTC / STC95.1%PTC 419 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 11 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
ELNSM54M-HC-LV-N-415415 W38.3013.7531.7013.10≈21.4%394 WAug 21, 2025
ELNSM54M-HC-LV-N-420420 W38.5013.8331.9013.17≈21.6%399 WAug 21, 2025
ELNSM54M-HC-LV-N-425425 W38.7013.9132.1013.24≈21.9%404 WAug 21, 2025
ELNSM54M-HC-LV-N-430430 W38.9013.9932.3013.32≈22.2%408 WAug 21, 2025
ELNSM54M-HC-LV-N-435435 W39.1014.0732.5013.39≈22.4%413 WAug 21, 2025
ELNSM54M-HC-LV-N-440440 W39.3013.8133.7613.04≈22.7%419 WAug 21, 2025
ELNSM54M-HC-LV-N-445445 W39.5013.8533.9713.10≈22.9%424 WAug 21, 2025
ELNSM54M-HC-LV-N-450450 W39.7013.8934.1813.17≈23.2%428 WDec 22, 2025
ELNSM54M-HC-LV-N-455455 W39.9013.9434.3413.25≈23.5%433 WDec 22, 2025
ELNSM54M-HC-LV-N-460460 W40.1013.9934.5013.34≈23.7%438 WDec 22, 2025
ELNSM54M-HC-LV-N-465465 W40.3014.0534.6513.42≈24.0%443 WDec 22, 2025
≈ efficiency = Pmax ÷ CEC-listed area 1.94 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.292 %/°C
Voc coefficient β−0.237 %/°C
Isc coefficient α+0.047 %/°C
Operating cell temperatureNOCT 43.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
415 W312.8 W30.98 V × 10.1 A79 W95%
420 W316.5 W31.18 V × 10.15 A79.9 W95%
425 W320.2 W31.37 V × 10.21 A80.8 W95%
430 W324.1 W31.57 V × 10.27 A81.8 W95%
435 W327.8 W31.76 V × 10.32 A82.8 W95%
440 W330.7 W31.39 V × 10.54 A83.2 W95%
445 W334.3 W31.58 V × 10.59 A84.1 W95%
450 W338.2 W31.78 V × 10.64 A85.1 W95%
455 W341.8 W31.93 V × 10.71 A86 W95%
460 W345.8 W32.08 V × 10.78 A87 W95%
465 W349.4 W32.22 V × 10.84 A87.9 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
41.4 V
Voc when cold
per panel
28.2 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V41.4 / 28.2 V⚠ Works; below MPPT at peak heat1.52
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V41.4 / 28.2 V✗ Not a match: module voltage below MPPT range1.16
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V41.4 / 28.2 V✓ Within range0.56
Enphase IQ8M-72-2-US260–460 W60 V30–45 V41.4 / 28.2 V⚠ Works; below MPPT at peak heat1.35
Enphase IQ8A-72-2-US295–500 W60 V32–45 V41.4 / 28.2 V⚠ Works; below MPPT at peak heat1.26
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67673711,7996.08
Palmdale1,83580712,9186.69
Chula Vista1,69674611,9406.11
Huntington Beach1,64372311,5675.89
Riverside1,69674611,9406.21
Santa Clarita1,72475912,1376.28
770Jan771Feb989Mar1,093Apr1,079May1,147Jun1,208Jul1,222Aug1,069Sep943Oct810Nov701DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 440 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
Elin Energy (Sirius PV) ELNSM54M-HC-LV-N 440440 W≈22.7%−0.29239.313.81———
Qcells Q.TRON BLK M-G2+ 440440 W≥22.5%−0.27639.8813.925 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-440QD440 W≈22.6%−0.29438.9714.2525 / 30 yrbrand 7× (2017–2025)39
Hyundai Energy Solutions HiN-T440NF(BK)440 W≈22.7%−0.29838.814.3925 / 30 yrbrand 5× (2017–2025)37
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Elin Energy (Sirius PV) ELNSM54M-HC-LV-N 440?

Calculated from the panel area (1.94 m²): about 22.7% for the 440 W class. 440 W over 1.94 m² equals about 227 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 737 kWh per year per 440 W panel in Los Angeles and about 807 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.292 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 41.4 V, Vmp at 74 °C cell = 28.2 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 41.4 V vs max input 60 V; Vmp when hot 28.2 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  3. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  4. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).