Cali-GrafCali-Graf
Solar panelElin Energy (Sirius PV)

Elin Energy (Sirius PV) ELNSM42M-HC-N-SNRN 410

84 half-cut cells. Power classes 400–420 W in the CEC list.

CEC listed · Aug 3, 2026UL 61730
Power class
  • Power (STC)410 WCEC nameplate
  • Efficiency≈23.6%calculated from area
  • %/°C Pmax−0.295CEC listing test
  • PTC / STC95.2%PTC 390 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 5 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
ELNSM42M-HC-N-SNRN-400400 W30.7716.0926.1215.34≈23.0%380 WAug 3, 2026
ELNSM42M-HC-N-SNRN-405405 W30.8916.1526.2515.45≈23.3%385 WAug 3, 2026
ELNSM42M-HC-N-SNRN-410410 W31.0316.2226.3815.57≈23.6%390 WAug 3, 2026
ELNSM42M-HC-N-SNRN-415415 W31.1616.3026.5115.68≈23.9%395 WAug 3, 2026
ELNSM42M-HC-N-SNRN-420420 W31.2916.3826.6415.79≈24.1%400 WAug 3, 2026
≈ efficiency = Pmax ÷ CEC-listed area 1.74 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.295 %/°C
Voc coefficient β−0.233 %/°C
Isc coefficient α+0.045 %/°C
Operating cell temperatureNOCT 43.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
400 W306.7 W25.29 V × 12.13 A75.8 W95%
405 W310.4 W25.42 V × 12.21 A76.7 W95%
410 W314.4 W25.54 V × 12.31 A77.7 W95%
415 W318.2 W25.67 V × 12.4 A78.6 W95%
420 W322 W25.79 V × 12.48 A79.6 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
32.7 V
Voc when cold
per panel
22 V
Vmp when hot
per panel
18
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–18
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–18
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet5–18
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window11–15

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V32.7 / 22 V✗ Not a match: module voltage below MPPT range1.41
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V32.7 / 22 V✗ Not a match: module voltage below MPPT range1.08
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V32.7 / 22 V✗ Not a match: module voltage below MPPT range0.53
Enphase IQ8M-72-2-US260–460 W60 V30–45 V32.7 / 22 V✗ Not a match: module voltage below MPPT range1.26
Enphase IQ8A-72-2-US295–500 W60 V32–45 V32.7 / 22 V✗ Not a match: module voltage below MPPT range1.17
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67668711,6826.08
Palmdale1,83575212,7906.69
Chula Vista1,69669511,8216.11
Huntington Beach1,64367411,4525.89
Riverside1,69669511,8216.21
Santa Clarita1,72470712,0166.28
763Jan763Feb979Mar1,082Apr1,069May1,135Jun1,196Jul1,210Aug1,058Sep933Oct802Nov694DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 410 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Elin Energy (Sirius PV) ELNSM42M-HC-N-SNRN 410410 W≈23.6%−0.29531.0316.22——
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W≈20.9%−0.33745.3711.2product 2022, 2023221
JA Solar JAM54S31-405/MR405 W≈21.3%−0.32937.2313.87product 2023, 2024152
REC Group REC410AA Pure410 W≈22.9%−0.2564910.35brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Elin Energy (Sirius PV) ELNSM42M-HC-N-SNRN 410?

Calculated from the panel area (1.74 m²): about 23.6% for the 410 W class. 410 W over 1.74 m² equals about 236 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 687 kWh per year per 410 W panel in Los Angeles and about 752 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.295 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.3% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–18 panels per string (Voc at 2 °C = 32.7 V, Vmp at 74 °C cell = 22 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  4. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  6. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  7. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).