Cali-GrafCali-Graf
Solar panelDehui Solar Power

Dehui Solar Power DH-M172W 540

144 half-cut cells. Power classes 530–550 W in the CEC list.

CEC listed · Sep 12, 2022UL 61730
Power class
  • Power (STC)540 WCEC nameplate
  • Efficiency≈21.1%calculated from area
  • %/°C Pmax−0.300CEC listing test
  • PTC / STC93.9%PTC 507 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 5 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
DH-M172W 530W530 W49.2513.7141.0612.91≈20.7%497 WSep 12, 2022
DH-M172W 535W535 W49.3813.7941.1812.99≈20.9%502 WSep 12, 2022
DH-M172W 540W540 W49.5113.8541.3213.07≈21.1%507 WSep 12, 2022
DH-M172W 545W545 W49.6413.9341.4613.15≈21.3%512 WSep 12, 2022
DH-M172W 550W550 W49.7714.0041.5913.23≈21.5%516 WSep 12, 2022
≈ efficiency = Pmax ÷ CEC-listed area 2.56 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.300 %/°C
Voc coefficient β−0.263 %/°C
Isc coefficient α+0.054 %/°C
Operating cell temperatureNOCT 46.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
530 W401.6 W38.93 V × 10.32 A102.8 W97%
535 W405.2 W39.04 V × 10.38 A103.7 W97%
540 W409.1 W39.18 V × 10.44 A104.7 W97%
545 W413 W39.31 V × 10.51 A105.7 W97%
550 W416.8 W39.43 V × 10.57 A106.7 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
1
PVEL Scorecards
Dehui Solar Power, 2024
2
RETC PV Module Index
Dehui Solar Power recognized 2023–2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Dehui Solar Power

YearRecognition
2023High Achievement in Performance (Pan file performance, Lid resistance)
2024Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.5 V
Voc when cold
per panel
34.2 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.5 / 34.2 V✗ Not a match: module voltage below MPPT range1.42
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.5 / 34.2 V✓ Within range0.69
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67690511,7666.08
Palmdale1,83599112,8826.69
Chula Vista1,69691611,9066.11
Huntington Beach1,64388711,5345.89
Riverside1,69691611,9066.21
Santa Clarita1,72493112,1026.28
768Jan769Feb986Mar1,090Apr1,076May1,144Jun1,205Jul1,219Aug1,066Sep940Oct808Nov699DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 540 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Dehui Solar Power DH-M172W 540540 W≈21.1%−0.30049.5113.85brand 1×—
JA Solar JAM72D30-540/MB540 W≈21.4%−0.33049.613.86product 2023, 20243
Canadian Solar CS6W-540MB-AG540 W≈21%−0.32449.213.9product 20241
LONGi LR5-72HBD-540M540 W≥21.1%−0.35449.513.85product 20261
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Dehui Solar Power

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index

Other series by SoCal permits

DH-M154BDH-M154TDH-M154WDH-M160BDH-M160TDH-M160W

Questions & answers

How efficient is the Dehui Solar Power DH-M172W 540?

Calculated from the panel area (2.56 m²): about 21.1% for the 540 W class. 540 W over 2.56 m² equals about 211 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 905 kWh per year per 540 W panel in Los Angeles and about 991 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.300 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.5 V, Vmp at 74 °C cell = 34.2 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.5 V vs max input 60 V; Vmp when hot 34.2 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Dehui Solar Power was named a Top Performer in 1 Scorecard (2024).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet BiHiKu6 BIFACIAL MONO PERC CS6W-520|525|530|535|540|545|550MB-AG.
  3. LONGi — manufacturer datasheet “LR5-72HBD Suitable for distributed projects Advanced module technology delivers superior”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. RETC — PV Module Index reports 2023–2024.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).