144 half-cut cells, bifacial, glass (dual-glass module). Power classes 590–620 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| CHSM72RN(DG)/F-BH-590 | 590 W | 51.00 | 14.50 | 42.86 | 13.77 | ≈21.9% | 558 W | Mar 11, 2024 |
| CHSM72RN(DG)/F-BH-595 | 595 W | 51.20 | 14.56 | 43.03 | 13.83 | ≈22.0% | 563 W | Mar 11, 2024 |
| CHSM72RN(DG)/F-BH-600 | 600 W | 51.40 | 14.65 | 43.19 | 13.89 | ≈22.2% | 568 W | Mar 11, 2024 |
| CHSM72RN(DG)/F-BH-605 | 605 W | 51.60 | 14.71 | 43.36 | 13.95 | ≈22.4% | 573 W | Mar 11, 2024 |
| CHSM72RN(DG)/F-BH-610 | 610 W | 51.80 | 14.79 | 43.53 | 14.01 | ≈22.6% | 578 W | Mar 11, 2024 |
| CHSM72RN(DG)/F-BH-615 | 615 W | 52.00 | 14.86 | 43.70 | 14.07 | ≈22.8% | 583 W | Mar 11, 2024 |
| CHSM72RN(DG)/F-BH-620 | 620 W | 52.20 | 14.94 | 43.87 | 14.13 | ≈23.0% | 587 W | Mar 11, 2024 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.275 %/°C |
| Voc coefficient β | −0.224 %/°C |
| Isc coefficient α | +0.042 %/°C |
| Operating cell temperature | NOCT 45.9 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 590 W | 441.4 W | 40.76 V × 10.83 A | 114.2 W | 97% |
| 595 W | 445.1 W | 40.92 V × 10.88 A | 115.2 W | 97% |
| 600 W | 448.7 W | 41.07 V × 10.92 A | 116.1 W | 97% |
| 605 W | 452.4 W | 41.24 V × 10.97 A | 117.1 W | 97% |
| 610 W | 456.1 W | 41.4 V × 11.02 A | 118 W | 97% |
| 615 W | 459.8 W | 41.56 V × 11.06 A | 119 W | 97% |
| 620 W | 463.6 W | 41.72 V × 11.11 A | 120 W | 97% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 1,014 | 12,168 | 6.08 |
| Palmdale | 1,835 | 1,110 | 13,322 | 6.69 |
| Chula Vista | 1,696 | 1,026 | 12,313 | 6.11 |
| Huntington Beach | 1,643 | 994 | 11,928 | 5.89 |
| Riverside | 1,696 | 1,026 | 12,313 | 6.21 |
| Santa Clarita | 1,724 | 1,043 | 12,516 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Chint New Energy CHSM72RN(DG)/F-BH 605 | 605 W | ≈22.4% | −0.275 | 51.6 | 14.71 | — | — |
| Phono Solar PS605M8GFH-24/TNH | 605 W | ≈23.6% | −0.293 | 53.6 | 13.96 | product 2024, 2025 | 1 |
| Qcells Q.PEAK DUO XL-G11S.3/BFG 600 | 600 W | ≈22.1% | −0.348 | 53.66 | 13.8 | product 2024, 2025, 2026 | 1 |
| VSUN (Vietnam Sunergy) VSUN600N-144MH | 600 W | ≈23.3% | −0.309 | 52.9 | 14.03 | brand 6× (2021–2026) | 1 |
Calculated from the panel area (2.7 m²): about 22.4% for the 605 W class. 605 W over 2.7 m² equals about 224 W per square meter.
PVWatts v8 with typical-year weather gives about 1,014 kWh per year per 605 W panel in Los Angeles and about 1,110 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.275 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 14.2% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 54.3 V, Vmp at 74 °C cell = 36.6 V). Final design must follow the inverter manual and NEC 690.7.
Yes. Rear gain depends on mounting height and ground reflectance.