Cali-GrafCali-Graf
Solar panelCHEN GUNES ENERJISI SANAYI VE…

CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE54-18X 405

108 half-cut cells. Power classes 390–420 W in the CEC list.

CEC listed · Sep 21, 2026UL 61730
Power class
  • Power (STC)405 WCEC nameplate
  • Efficiency≈20.9%calculated from area
  • %/°C Pmax−0.351CEC listing test
  • PTC / STC92.9%PTC 376 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
FE54-18X-390390 W36.7313.6730.8512.66≈20.1%362 WSep 21, 2026
FE54-18X-395395 W36.9013.7531.0112.74≈20.4%367 WSep 21, 2026
FE54-18X-400400 W37.0513.8331.1712.84≈20.6%371 WSep 21, 2026
FE54-18X-405405 W37.1913.9131.3112.95≈20.9%376 WSep 21, 2026
FE54-18X-410410 W37.3313.9831.4413.05≈21.1%381 WSep 21, 2026
FE54-18X-415415 W37.4814.0631.6013.14≈21.4%386 WSep 21, 2026
FE54-18X-420420 W37.6314.1431.7413.24≈21.6%390 WSep 21, 2026
≈ efficiency = Pmax ÷ CEC-listed area 1.94 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.351 %/°C
Voc coefficient β−0.266 %/°C
Isc coefficient α+0.052 %/°C
Operating cell temperatureNOCT 46.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
390 W289.4 W27.33 V × 10.59 A76 W97%
395 W292.7 W27.47 V × 10.66 A76.9 W97%
400 W296.6 W27.61 V × 10.74 A77.9 W97%
405 W300.4 W27.74 V × 10.83 A78.9 W97%
410 W304 W27.85 V × 10.91 A79.8 W97%
415 W307.7 W27.99 V × 10.99 A80.8 W97%
420 W311.4 W28.12 V × 11.07 A81.8 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
39.5 V
Voc when cold
per panel
25.1 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–15
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–15
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–15
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V39.5 / 25.1 V⚠ Works; below MPPT at peak heat1.4
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V39.5 / 25.1 V✗ Not a match: module voltage below MPPT range1.07
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V39.5 / 25.1 V⚠ Works; below MPPT at peak heat0.52
Enphase IQ8M-72-2-US260–460 W60 V30–45 V39.5 / 25.1 V⚠ Works; below MPPT at peak heat1.25
Enphase IQ8A-72-2-US295–500 W60 V32–45 V39.5 / 25.1 V✗ Not a match: module voltage below MPPT range1.16
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67667911,5396.08
Palmdale1,83574312,6346.69
Chula Vista1,69668711,6776.11
Huntington Beach1,64366511,3125.89
Riverside1,69668711,6776.21
Santa Clarita1,72469811,8706.28
753Jan754Feb967Mar1,069Apr1,055May1,122Jun1,181Jul1,195Aug1,045Sep922Oct792Nov686DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 405 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE54-18X 405405 W≈20.9%−0.35137.1913.91——
Qcells Q.PEAK DUO BLK ML-G10+ 405405 W≥20.6%−0.36245.3411.17product 2022, 2023221
JA Solar JAM54S31-405/MR405 W≈21.3%−0.32937.2313.87product 2023, 2024152
REC Group REC405AA Pure405 W≈22.6%−0.25648.910.3brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE54-18X 405?

Calculated from the panel area (1.94 m²): about 20.9% for the 405 W class. 405 W over 1.94 m² equals about 209 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 679 kWh per year per 405 W panel in Los Angeles and about 743 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.351 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 39.5 V, Vmp at 74 °C cell = 25.1 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  4. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  6. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  7. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).