108 half-cut cells, bifacial. Power classes 425–455 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| CTTC425HC12-08 | 425 W | 38.30 | 14.05 | 32.20 | 13.23 | ≈21.8% | 403 W | Jun 2, 2025 |
| CTTC430HC12-08 | 430 W | 38.40 | 14.13 | 32.50 | 13.28 | ≈22.1% | 408 W | Jun 2, 2025 |
| CTTC435HC12-08 | 435 W | 38.50 | 14.22 | 32.80 | 13.32 | ≈22.3% | 412 W | Jun 2, 2025 |
| CTTC440HC12-08 | 440 W | 38.60 | 14.30 | 33.00 | 13.36 | ≈22.6% | 417 W | Jun 2, 2025 |
| CTTC445HC12-08 | 445 W | 38.80 | 14.38 | 33.20 | 13.40 | ≈22.8% | 422 W | Jun 2, 2025 |
| CTTC450HC12-08 | 450 W | 38.80 | 14.47 | 33.50 | 13.44 | ≈23.1% | 427 W | Jun 2, 2025 |
| CTTC455HC12-08 | 455 W | 39.00 | 14.54 | 33.80 | 13.48 | ≈23.3% | 432 W | Jun 2, 2025 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.303 %/°C |
| Voc coefficient β | −0.229 %/°C |
| Isc coefficient α | +0.049 %/°C |
| Operating cell temperature | NOCT 43.5 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 425 W | 312.5 W | 28 V × 11.16 A | 79.7 W | 94% |
| 430 W | 320.6 W | 28.4 V × 11.29 A | 81.6 W | 95% |
| 435 W | 327.8 W | 28.7 V × 11.42 A | 83.5 W | 96% |
| 440 W | 335 W | 29 V × 11.55 A | 85.5 W | 97% |
| 445 W | 342.2 W | 29.3 V × 11.68 A | 87.1 W | 98% |
| 450 W | 350.8 W | 29.7 V × 11.81 A | 89.4 W | 99% |
| 455 W | 358.5 W | 30 V × 11.95 A | 91.4 W | 100% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–14 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–14 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–14 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–12 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 40.8 / 27.7 V | ✗ Not a match: module voltage below MPPT range | 1.18 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 40.8 / 27.7 V | ⚠ Works; below MPPT at peak heat | 0.58 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 40.8 / 27.7 V | ⚠ Works; below MPPT at peak heat | 1.38 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 40.8 / 27.7 V | ⚠ Works; below MPPT at peak heat | 1.29 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 754 | 12,067 | 6.08 |
| Palmdale | 1,835 | 826 | 13,212 | 6.69 |
| Chula Vista | 1,696 | 763 | 12,211 | 6.11 |
| Huntington Beach | 1,643 | 739 | 11,830 | 5.89 |
| Riverside | 1,696 | 763 | 12,211 | 6.21 |
| Santa Clarita | 1,724 | 776 | 12,413 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| CertainTeed CTTC450HC12-08 | 450 W | ≈23.1% | −0.303 | 38.8 | 14.47 | — | 3 |
| Qcells Q.TRON BLK M-G2+ 445 | 445 W | ≈22.8% | −0.276 | 40.16 | 13.98 | brand 11× (2016–2026) | 40 |
| Hyundai Energy Solutions HiN-T450NF(BK) | 450 W | ≈23.2% | −0.298 | 39.2 | 14.53 | brand 5× (2017–2025) | 37 |
| REC Group REC450AA Pure-RX | 450 W | ≈22.3% | −0.248 | 65.1 | 8.81 | brand 9× (2016–2025) | 33 |
Calculated from the panel area (1.95 m²): about 23.1% for the 450 W class. 450 W over 1.95 m² equals about 231 W per square meter.
PVWatts v8 with typical-year weather gives about 754 kWh per year per 450 W panel in Los Angeles and about 826 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.303 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.7% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 40.8 V, Vmp at 74 °C cell = 27.7 V). Final design must follow the inverter manual and NEC 690.7.
Yes. Rear gain depends on mounting height and ground reflectance.
Building permits name this series 3 times (Nov 2025 – Jul 2026). The most active licensed installers are B V I Solar, Preman A Roofing Inc, Solar Discovery Inc.