Cali-GrafCali-Graf
Solar panelCanadian Solar

Canadian Solar CS6U-325P

72 cells, PERC. Power classes 310–340 W in the CEC list; datasheet covers 325–335 W.

CEC listed · Sep 12, 2022UL 61730PERC
Power class
  • Power (STC)325 Wtolerance +5 / −0 W
  • Efficiency≥16.7%datasheet minimum
  • %/°C Pmax−0.40CEC test: −0.410
  • PTC / STC92.3%PTC 300 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · Canadian Solar datasheet · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
CS6U-310P310 W44.909.0836.408.52≈17.8%286 WSep 12, 2022
CS6U-315P315 W45.109.1836.608.61≈18.1%291 WSep 12, 2022
CS6U-320P320 W45.309.2636.808.69≈18.4%295 WSep 12, 2022
CS6U-325P325 W45.509.3437.008.78≥16.7%300 WSep 12, 2022
CS6U-330P330 W45.609.4537.208.88≥17.0%305 WSep 12, 2022
CS6U-335P335 W45.809.5437.408.96≥17.2%310 WSep 12, 2022
CS6U-340P340 W45.909.6237.609.05≈19.5%314 WSep 12, 2022
≈ efficiency = Pmax ÷ CEC-listed area 1.74 m² for classes outside the datasheet.

Build & dimensions

CEC PV Module List (Oct 7, 2026) · Canadian Solar datasheets

Heat & cold behaviour

Canadian Solar datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.40 %/°C−0.410 %/°C
Voc coefficient β−0.31 %/°C−0.312 %/°C
Isc coefficient α+0.05 %/°C+0.036 %/°C
Vmp coefficient≈ −0.45 %/°C—
Operating cell temperatureNMOT 43 ± 3 °CNOCT 43.9 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NMOT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
325 W239.042.407.5434.007.03
330 W243.042.507.6334.207.10
335 W247.042.607.7034.407.17

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
310 W227.5 W34.19 V × 6.65 A59.9 W97%
315 W231.1 W34.38 V × 6.72 A60.9 W97%
320 W234.5 W34.57 V × 6.79 A61.8 W97%
325 W238.3 W34.75 V × 6.86 A62.8 W97%
330 W242.3 W34.94 V × 6.93 A63.9 W97%
335 W245.8 W35.13 V × 7 A64.8 W97%
340 W249.6 W35.32 V × 7.07 A65.8 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Certifications

CEC PV Module List (Oct 7, 2026) · Canadian Solar datasheet
UL 61730UL 1703IEC 61215IEC 61730IEC 61701IEC 62716IEC 60068MCSFire rating Type 1 (UL 61730)ISO 14001ISO 45001ISO 9001

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
Canadian Solar named Top Performer, 2020–2026
1
RETC PV Module Index
Canadian Solar, 2025
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Canadian Solar

YearRecognition
2025Reliability High Achiever

Inverter compatibility & string sizing

Canadian Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
48.7 V
Voc when cold
per panel
28.8 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V48.7 / 28.8 V⚠ Works; below MPPT at peak heat1.12
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V48.7 / 28.8 V✗ Not a match: module voltage below MPPT range0.86
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V48.7 / 28.8 V✓ Within range0.42
Enphase IQ8M-72-2-US260–460 W60 V30–45 V48.7 / 28.8 V⚠ Works; below MPPT at peak heat1
Enphase IQ8A-72-2-US295–500 W60 V32–45 V48.7 / 28.8 V⚠ Works; below MPPT at peak heat0.93
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67654511,9836.08
Palmdale1,83559613,1206.69
Chula Vista1,69655112,1266.11
Huntington Beach1,64353411,7475.89
Riverside1,69655112,1266.21
Santa Clarita1,72456012,3276.28
782Jan783Feb1,005Mar1,110Apr1,096May1,165Jun1,227Jul1,241Aug1,085Sep957Oct823Nov712DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 325 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizeWarrantyPVEL (product / brand)SoCal permits (series)
Canadian Solar CS6U-325P325 W≥16.7%−0.41045.59.34——brand 5×—
JinkoSolar JKM325M-60HBL325 W≈19.3%−0.40741.110.266.3 × 39.4 in10 / 25 yrbrand 12× (2014–2026)45
Qcells Q.PEAK DUO-G8+ 330330 W≈18.4%−0.34339.7110.5268.5 × 40.6 in25 / 25 yrproduct 202220
LG Electronics LG325N1C-N5325 W≈18.8%−0.34240.910.5766.9 × 40 in25 / 25 yrproduct 20215
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Canadian Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

CS6R-xxxMS-HL · 46CS3N-xxxMS · 46CS6.1-54TM-xxxH · 9CS1Y-xxxMS · 6CS3W-xxxMS · 6CS3W-xxxMB-AG · 5

Questions & answers

How efficient is the Canadian Solar CS6U-325P?

The Canadian Solar datasheet guarantees at least 16.7% module efficiency for the 325 W class (up to 17.2% for 335 W). 325 W over 1.74 m² equals about 187 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 545 kWh per year per 325 W panel in Los Angeles and about 596 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.40 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–12 panels per string (Voc at 2 °C = 48.7 V, Vmp at 74 °C cell = 28.8 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 48.7 V vs max input 60 V; Vmp when hot 28.8 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Canadian Solar was named a Top Performer in 5 Scorecards (2020–2026).

What fire rating does it have?

UL 61730 fire rating Type 1 per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — manufacturer datasheet “MAXPOWER CS6U- 340| 345| 350P HIGH EFFICIENCY POLY MODULE”.
  3. Canadian Solar — manufacturer datasheet “MAXPOWER CS6U- 325| 330| 335P Canadian Solar‘s modules use the latest innovative”.
  4. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  5. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  6. Qcells — manufacturer datasheet “Q.PEAK DUO-G8+ 345-360 EN ENDURING HIGH”.
  7. LG Electronics — datasheet Specification Sheet.
  8. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2020–2026.
  9. RETC — PV Module Index report.
  10. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  11. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  12. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  13. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  14. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).