Cali-GrafCali-Graf
Solar panelCanadian Solar

Canadian Solar CS6R-395MS-HL {Blk}

108 cells, PERC. Power classes 380–420 W in the CEC list; datasheet covers 380–405 W.

CEC listed · Aug 1, 2022UL 61730PVEL Top Performer 2024PERCInstalled in 46 SoCal permits
Power class
  • Power (STC)395 Wtolerance +10 / −0 W
  • Efficiency≥20.2%datasheet minimum
  • %/°C Pmax−0.34CEC test: −0.328
  • Degradation / yr0.55%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Canadian Solar datasheet · Cali-Graf calculation · 14 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
CS6R-380MS-HL {Blk}380 W36.0013.5530.0012.69≥19.5%357 WAug 1, 2022
CS6R-385MS-HL {Blk}385 W36.2013.6330.2012.77≥19.7%362 WAug 1, 2022
CS6R-390MS-HL {Blk}390 W36.4013.7030.4012.84≥20.0%367 WAug 1, 2022
CS6R-390MS-HL {Wht}390 W36.4013.7030.4012.84≥20.0%367 WAug 1, 2022
CS6R-395MS-HL {Blk}395 W36.6013.7730.6012.91≥20.2%372 WAug 1, 2022
CS6R-395MS-HL {Wht}395 W36.6013.7730.6012.91≥20.2%372 WAug 1, 2022
CS6R-400MS-HL {Blk}400 W36.8013.8530.8012.99≥20.5%377 WAug 1, 2022
CS6R-400MS-HL {Wht}400 W36.8013.8530.8012.99≥20.5%377 WAug 1, 2022
CS6R-405MS-HL {Blk}405 W37.0013.9331.0013.07≥20.7%382 WAug 1, 2022
CS6R-405MS-HL {Wht}405 W37.0013.9331.0013.07≥20.7%382 WAug 1, 2022
CS6R-410MS-HL {Blk}410 W37.2014.0131.2013.15≈21.0%386 WAug 1, 2022
CS6R-410MS-HL {Wht}410 W37.2014.0131.2013.15≈21.0%386 WAug 1, 2022
CS6R-415MS-HL {Wht}415 W37.4014.0931.4013.23≈21.3%391 WAug 1, 2022
CS6R-420MS-HL {Wht}420 W37.6014.1731.6013.31≈21.5%396 WAug 1, 2022
≈ efficiency = Pmax ÷ CEC-listed area 1.95 m² for classes outside the datasheet.

Build & dimensions

CEC PV Module List (Oct 7, 2026) · Canadian Solar datasheets

Heat & cold behaviour

Canadian Solar datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.34 %/°C−0.328 %/°C
Voc coefficient β−0.26 %/°C−0.261 %/°C
Isc coefficient α+0.05 %/°C+0.060 %/°C
Vmp coefficient≈ −0.39 %/°C—
Operating cell temperatureNMOT 42 ± 3 °CNOCT 43.6 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NMOT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
380 W284.033.9010.9128.1010.12
385 W288.034.1010.9828.3010.19
390 W291.034.2011.0528.4010.26
390 W291.034.2011.0528.4010.26
395 W295.034.4011.1128.6010.33
395 W295.034.4011.1128.6010.33
400 W299.034.6011.1728.8010.39
400 W299.034.6011.1728.8010.39
405 W303.034.7011.2329.0010.45
405 W303.034.7011.2329.0010.45

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
380 W288 W28.73 V × 10.03 A74.4 W98%
385 W291.7 W28.92 V × 10.09 A75.4 W98%
390 W295.3 W29.11 V × 10.14 A76.3 W98%
390 W295.7 W28.7 V × 10.3 A75.7 W97%
395 W298.8 W29.3 V × 10.2 A77.2 W98%
395 W299.2 W28.89 V × 10.36 A76.6 W97%
400 W302.7 W29.49 V × 10.26 A78.2 W98%
400 W303.1 W29.08 V × 10.42 A77.6 W97%
405 W306.5 W29.68 V × 10.33 A79.2 W98%
405 W306.9 W29.27 V × 10.49 A78.6 W97%
410 W310.4 W29.87 V × 10.39 A80.2 W98%
410 W310.8 W29.46 V × 10.55 A79.6 W97%
415 W314.7 W29.65 V × 10.61 A80.6 W97%
420 W318.6 W29.84 V × 10.68 A81.6 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Certifications

CEC PV Module List (Oct 7, 2026) · Canadian Solar datasheets
UL 61730IEC 61215IEC 61730IEC 61701IEC 62716Fire rating Class C (UL 61730)ISO 14001ISO 45001ISO 9001

Warranty & degradation

Canadian Solar datasheet

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2024
PVEL Top Performer
this series
3
Tests passed as Top Performer
HSS, LID+LETID, MSS
5
PVEL Scorecards
Canadian Solar named Top Performer, 2020–2026
1
RETC PV Module Index
Canadian Solar, 2025

PVEL Top Performer tests

YearProductTests
2024CS6R-xxxMS-HLHSSLID+LETIDMSS
2024CS6R-xxxMS (closely related product name)LID+LETID

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — Canadian Solar

YearRecognition
2025Reliability High Achiever

Inverter compatibility & string sizing

Canadian Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
38.8 V
Voc when cold
per panel
24.8 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–15
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–15
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet5–15
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V38.8 / 24.8 V⚠ Works; below MPPT at peak heat1.36
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V38.8 / 24.8 V✗ Not a match: module voltage below MPPT range1.04
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V38.8 / 24.8 V⚠ Works; below MPPT at peak heat0.51
Enphase IQ8M-72-2-US260–460 W60 V30–45 V38.8 / 24.8 V⚠ Works; below MPPT at peak heat1.22
Enphase IQ8A-72-2-US295–500 W60 V32–45 V38.8 / 24.8 V✗ Not a match: module voltage below MPPT range1.13
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67666211,9166.08
Palmdale1,83572513,0476.69
Chula Vista1,69667012,0596.11
Huntington Beach1,64364911,6825.89
Riverside1,69667012,0596.21
Santa Clarita1,72468112,2586.28
778Jan779Feb999Mar1,103Apr1,090May1,158Jun1,220Jul1,234Aug1,079Sep952Oct818Nov708DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs CS6R-xxxMS-HL panels in SoCal

building permits · CSLB License Master
46
Permits naming this series
Sep 2023 – Jul 2026
5
Licensed installers
CSLB license on the permit
2
Jurisdictions so far
LA County (unincorp.) (33), Palmdale (13)

Permits over time

1Q3 ’233Q4 ’235Q1 ’2410Q2 ’2410Q3 ’249Q4 ’243Q1 ’253Q2 ’250Q3 ’250Q4 ’251Q1 ’260Q2 ’261Q3 ’26permits per quarter

Power class named in permit

395 W
22
390 W
14
400 W
10

Top ZIP codes

  • ZIP 935516
  • ZIP 935505
  • ZIP 900233
  • ZIP 913843
  • ZIP 935363
  • ZIP 905022
  • ZIP 935432
  • ZIP 917452
  • Other ZIP codes17

Typical system

median 7 kW, 19 panels (n = 31)

Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Microinverters

Enphase IQ8+
16
Enphase IQ8A
2

Inverters

SolarEdge SE…H (HD-Wave)
2

Optimizers

SolarEdge Power Optimizer
2
Tigo TS4
2

Batteries

Tesla Powerwall 3
19
Enphase IQ Battery 5P
7
EG4 (model not specified)
2
Number of permits naming both this panel series and the product; 44 of 46 permits list other equipment.

Compare with similar 395 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Canadian Solar CS6R-395MS-HL {Blk}395 W≥20.2%−0.32836.613.77product 202446
Qcells Q.PEAK DUO BLK ML-G10+ 395395 W≥20.1%−0.36245.2711.1product 2022, 2023221
JA Solar JAM54S31-395/MR395 W≈20.8%−0.32936.9813.7product 2023, 2024152
REC Group REC395AA Pure395 W≈22%−0.25648.710.2brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About Canadian Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

CS3N-xxxMS · 46CS6.1-54TM-xxxH · 9CS1Y-xxxMS · 6CS3W-xxxMS · 6CS3W-xxxMB-AG · 5CS7N-xxxMB-AG · 2

Questions & answers

How efficient is the Canadian Solar CS6R-395MS-HL {Blk}?

The Canadian Solar datasheet guarantees at least 20.2% module efficiency for the 395 W class (up to 20.7% for 405 W). 395 W over 1.95 m² equals about 203 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 662 kWh per year per 395 W panel in Los Angeles and about 725 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 38.8 V, Vmp at 74 °C cell = 24.8 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

25 years on the product (manufacturer datasheet).

Has this panel been reliability-tested?

CS6R-xxxMS-HL was a PVEL Top Performer in 2024 (HSS, LID+LETID, MSS).

What fire rating does it have?

UL 61730 fire rating Class C per datasheet.

Who installs it in Southern California?

Building permits name this series 46 times (Sep 2023 – Jul 2026). The most active licensed installers are Grid Alternatives, Semper Solaris, Solar Shoppers Construction.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet HiKu6 (All-Black) ALL BLACK MONO PERC CS6R-380|385|390|395|400|405MS-HL.
  3. Canadian Solar — manufacturer datasheet “HiKu6 (All-Black) ALL BLACK MONO PERC CS6R-380|385|390|395|400|405MS-HL”.
  4. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  5. Canadian Solar — document library on the manufacturer’s website (links above).
  6. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2020–2026.
  7. RETC — PV Module Index report.
  8. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  9. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  10. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  11. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Oct 2023 – May 2025); City of Palmdale (Sep 2023 – Jul 2026). Equipment matched from permit descriptions by model number.
  12. Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
  13. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).