Cali-GrafCali-Graf
Solar panelCanadian Solar

Canadian Solar CS6PH-265P

108 half-cut cells. Power classes 250–280 W in the CEC list.

CEC listed · Feb 22, 2021UL 61730
Power class
  • Power (STC)265 WCEC nameplate
  • Efficiency≈17.1%calculated from area
  • %/°C Pmax−0.365CEC listing test
  • PTC / STC92.9%PTC 246 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
CS6PH-250P250 W34.209.5528.608.75≈16.1%232 WFeb 22, 2021
CS6PH-255P255 W34.409.6228.808.86≈16.5%237 WFeb 22, 2021
CS6PH-260P260 W34.609.6929.008.97≈16.8%241 WFeb 22, 2021
CS6PH-265P265 W34.809.7629.209.08≈17.1%246 WFeb 22, 2021
CS6PH-270P270 W35.009.8329.409.19≈17.4%251 WFeb 22, 2021
CS6PH-275P275 W35.209.9029.609.30≈17.7%256 WFeb 22, 2021
CS6PH-280P280 W35.409.9729.809.40≈18.1%260 WFeb 22, 2021
≈ efficiency = Pmax ÷ CEC-listed area 1.55 m².
CEC note: Formerly listed under Canadian Solar Inc.

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.365 %/°C
Voc coefficient β−0.282 %/°C
Isc coefficient α+0.056 %/°C
Operating cell temperatureNOCT 44.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
250 W187.7 W26.29 V × 7.14 A49 W98%
255 W191.4 W26.47 V × 7.23 A50 W98%
260 W195.1 W26.65 V × 7.32 A51 W98%
265 W198.9 W26.84 V × 7.41 A52 W98%
270 W202.7 W27.02 V × 7.5 A52.9 W98%
275 W206.5 W27.21 V × 7.59 A53.9 W98%
280 W210.1 W27.39 V × 7.67 A54.9 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
Canadian Solar named Top Performer, 2020–2026
1
RETC PV Module Index
Canadian Solar, 2025
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Canadian Solar

YearRecognition
2025Reliability High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
37.1 V
Voc when cold
per panel
23.2 V
Vmp when hot
per panel
16
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–16
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–16
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet5–16
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window11–13

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V37.1 / 23.2 V⚠ Works; below MPPT at peak heat0.91
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V37.1 / 23.2 V⚠ Works; below MPPT at peak heat0.34
Enphase IQ8M-72-2-US260–460 W60 V30–45 V37.1 / 23.2 V✗ Not a match: module voltage below MPPT range0.82
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67644411,5486.08
Palmdale1,83548612,6436.69
Chula Vista1,69644911,6856.11
Huntington Beach1,64343511,3205.89
Riverside1,69644911,6856.21
Santa Clarita1,72445711,8786.28
754Jan754Feb968Mar1,069Apr1,056May1,122Jun1,182Jul1,196Aug1,046Sep923Oct793Nov686DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 265 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
Canadian Solar CS6PH-265P265 W≈17.1%−0.36534.89.76brand 5×
Hyundai Energy Solutions HiS-C265RG(BK)265 W≥16.4%−0.38237.988.95brand 5× (2017–2025)
ZNShine Solar ZXM6-72-265/M265 W≈13.3%−0.52444.148.22brand 8× (2016–2026)
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Canadian Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

CS6R-xxxMS-HL · 46CS3N-xxxMS · 46CS6.1-54TM-xxxH · 9CS1Y-xxxMS · 6CS3W-xxxMS · 6CS3W-xxxMB-AG · 5

Questions & answers

How efficient is the Canadian Solar CS6PH-265P?

Calculated from the panel area (1.55 m²): about 17.1% for the 265 W class. 265 W over 1.55 m² equals about 171 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 444 kWh per year per 265 W panel in Los Angeles and about 486 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.365 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.9% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–16 panels per string (Voc at 2 °C = 37.1 V, Vmp at 74 °C cell = 23.2 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Canadian Solar was named a Top Performer in 5 Scorecards (2020–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [Customized Module] RG(BK) Series (PERC) 265~285W.
  3. ZNShine Solar — manufacturer datasheet “ZXM6-72 Series Znshinesolar 5BB Monocrystalline PV Module”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2020–2026.
  5. RETC — PV Module Index report.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).