Cali-GrafCali-Graf
Solar panelCanadian Solar

Canadian Solar CS6.2-66HB-625HP

132 half-cut cells, bifacial. Power classes 600–650 W in the CEC list.

CEC listed · Aug 1, 2025UL 61730BifacialPVEL Top Performer 2026
Power class
  • Power (STC)625 WCEC nameplate
  • Efficiency≈23.9%calculated from area
  • %/°C Pmax−0.245CEC listing test
  • PTC / STC95.7%PTC 598 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 11 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
CS6.2-66HB-600HP600 W49.8015.2042.4014.14≈22.9%574 WSep 22, 2025
CS6.2-66HB-605HP605 W49.9015.3042.5014.25≈23.1%579 WAug 1, 2025
CS6.2-66HB-610HP610 W50.0015.4242.6014.36≈23.3%584 WAug 1, 2025
CS6.2-66HB-615HP615 W50.0015.5342.6014.46≈23.5%589 WAug 1, 2025
CS6.2-66HB-620HP620 W50.1015.6542.6014.58≈23.7%594 WAug 1, 2025
CS6.2-66HB-625HP625 W50.1015.7542.6014.69≈23.9%598 WAug 1, 2025
CS6.2-66HB-630HP630 W50.2015.8242.6014.79≈24.0%603 WAug 1, 2025
CS6.2-66HB-635HP635 W50.3015.9242.7014.88≈24.2%608 WAug 1, 2025
CS6.2-66HB-640HP640 W50.4016.0142.7014.99≈24.4%613 WAug 1, 2025
CS6.2-66HB-645HP645 W50.4016.1342.8015.07≈24.6%618 WAug 1, 2025
CS6.2-66HB-650HP650 W50.5016.2242.9015.16≈24.8%623 WAug 1, 2025
≈ efficiency = Pmax ÷ CEC-listed area 2.62 m².
CEC note: Formerly listed under CSI Solar Co., Ltd.

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.245 %/°C
Voc coefficient β−0.218 %/°C
Isc coefficient α+0.067 %/°C
Operating cell temperatureNOCT 44.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
600 W460.5 W40.19 V × 11.46 A114.2 W95%
605 W465.2 W40.28 V × 11.55 A115.3 W95%
610 W469.9 W40.38 V × 11.64 A116.5 W95%
615 W473.2 W40.38 V × 11.72 A117.3 W95%
620 W477.1 W40.38 V × 11.82 A118.3 W95%
625 W480.7 W40.38 V × 11.91 A119.2 W95%
630 W484 W40.38 V × 11.99 A120 W95%
635 W488.1 W40.47 V × 12.06 A121 W95%
640 W491.7 W40.47 V × 12.15 A121.9 W95%
645 W495.5 W40.56 V × 12.21 A122.8 W95%
650 W499.6 W40.66 V × 12.29 A123.8 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026) · Clean Energy Council (Australia)
UL 61730IEC 61215:2021 / IEC 61730:2023

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2026
PVEL Top Performer
this series
6
Tests passed as Top Performer
HSS, LID+LETID, MSS, PAN, PID, TC
5
PVEL Scorecards
Canadian Solar named Top Performer, 2020–2026
1
RETC PV Module Index
Canadian Solar, 2025

PVEL Top Performer tests

YearProductTests
2026CS6.2-66HB-xxxHPHSSLID+LETIDMSSPANPIDTC
2026CS6.2-66HB-xxx (closely related product name)LID+LETIDPANTC
2026CS6.2-66HB-xxxH (closely related product name)LID+LETIDPANTC

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — Canadian Solar

YearRecognition
2025Reliability High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.6 V
Voc when cold
per panel
36.1 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,04811,5226.08
Palmdale1,8351,14712,6166.69
Chula Vista1,6961,06011,6606.11
Huntington Beach1,6431,02711,2965.89
Riverside1,6961,06011,6606.21
Santa Clarita1,7241,07811,8526.28
752Jan753Feb966Mar1,067Apr1,054May1,120Jun1,180Jul1,194Aug1,044Sep921Oct791Nov685DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 625 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)
Canadian Solar CS6.2-66HB-625HP625 W≈23.9%−0.24550.115.75—product 2026
Hyundai Energy Solutions HiS-T625NJ625 W≈22.6%−0.29457.1513.8212 / 30 yrbrand 5× (2017–2025)
JinkoSolar JKM625N-66HL4M-BDV625 W≈23.1%−0.29949.2816.1412 / 30 yrproduct 2025
Waaree BiN-17-625625 W≥22.4%−0.30856.8813.8812 / 30 yrproduct 2025, 2026
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Canadian Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

CS6R-xxxMS-HL · 46CS3N-xxxMS · 46CS6.1-54TM-xxxH · 9CS1Y-xxxMS · 6CS3W-xxxMS · 6CS3W-xxxMB-AG · 5

Questions & answers

How efficient is the Canadian Solar CS6.2-66HB-625HP?

Calculated from the panel area (2.62 m²): about 23.9% for the 625 W class. 625 W over 2.62 m² equals about 239 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,048 kWh per year per 625 W panel in Los Angeles and about 1,147 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.245 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 12.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.6 V, Vmp at 74 °C cell = 36.1 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

CS6.2-66HB-xxxHP was a PVEL Top Performer in 2026 (HSS, LID+LETID, MSS, PAN, PID, TC).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [US] NJ(HiS) Series (N TOPCon Bifacial) 635~645W.
  3. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR PRODUCT.
  4. Waaree — datasheet ELITE SERIES BiN-17-615-645 WEL-EPD-615-645-156-BiN-HC-04-27.05.2024 35mm.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2020–2026.
  6. RETC — PV Module Index report.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. Clean Energy Council (Australia) — Approved PV modules list (as of Oct 8, 2026).
  9. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  10. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  11. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  12. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).