144 half-cut cells, PERC. Power classes 430–470 W in the CEC list; datasheet covers 435–465 W.

CEC listed · Nov 23, 2020UL 61730PVEL Top Performer 2023PERCInstalled in 6 SoCal permits
Power class
  • Power (STC)455 Wtolerance +10 / −0 W
  • Efficiency≥20.6%datasheet minimum
  • %/°C Pmax−0.34CEC test: −0.324
  • Degradation / yr0.55%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · Canadian Solar datasheet · 9 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
CS3W-430MS430 W48.3011.3740.3010.68≈20.1%400 WNov 23, 2020
CS3W-435MS435 W48.5011.4240.5010.75≥19.7%405 WNov 23, 2020
CS3W-440MS440 W48.7011.4840.7010.82≥19.9%410 WNov 23, 2020
CS3W-445MS445 W48.9011.5440.9010.89≥20.1%414 WNov 23, 2020
CS3W-450MS450 W49.1011.6041.1010.96≥20.4%419 WNov 23, 2020
CS3W-455MS455 W49.3011.6641.3011.02≥20.6%429 WNov 23, 2020
CS3W-460MS460 W49.5011.7241.5011.09≥20.8%429 WNov 23, 2020
CS3W-465MS465 W49.7011.7841.7011.16≥21.0%434 WNov 23, 2020
CS3W-470MS470 W49.9011.8441.9011.22≈21.6%444 WSep 13, 2021
≈ efficiency = Pmax ÷ CEC-listed area 2.14 m² for classes outside the datasheet.
CEC note: Formerly listed under Canadian Solar Inc.

Build & dimensions

CEC PV Module List (Oct 7, 2026) · Canadian Solar datasheet

Heat & cold behaviour

Canadian Solar datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.34 %/°C−0.324 %/°C
Voc coefficient β−0.26 %/°C−0.260 %/°C
Isc coefficient α+0.05 %/°C+0.052 %/°C
Vmp coefficient≈ −0.39 %/°C—
Operating cell temperatureNMOT 41 ± 3 °CNOCT 43.4 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NMOT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
435 W326.045.809.2138.008.59
440 W330.046.009.2638.208.65
445 W334.046.209.3138.308.71
450 W338.046.409.3538.508.76
455 W341.046.609.4038.708.82
460 W345.046.809.4538.908.87
465 W349.047.009.5039.108.92

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
430 W313.1 W37.38 V × 8.38 A81.8 W95%
435 W316.8 W37.57 V × 8.43 A82.7 W95%
440 W320.4 W37.75 V × 8.49 A83.7 W95%
445 W324 W37.94 V × 8.54 A84.6 W95%
450 W327.7 W38.13 V × 8.6 A85.6 W95%
455 W337.7 W38.89 V × 8.68 A86.8 W95%
460 W334.8 W38.5 V × 8.7 A87.5 W95%
465 W338.6 W38.68 V × 8.75 A88.4 W95%
470 W348.8 W39.45 V × 8.84 A89.7 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Certifications

CEC PV Module List (Oct 7, 2026) · Canadian Solar datasheet
UL 61730IEC 61215IEC 61730IEC 61701IEC 62716MCSISO 14001ISO 45001ISO 9001

Warranty & degradation

Canadian Solar datasheet

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2023
PVEL Top Performer
this series
3
Tests passed as Top Performer
DH, LID+LETID, PID
5
PVEL Scorecards
Canadian Solar named Top Performer, 2020–2026
1
RETC PV Module Index
Canadian Solar, 2025

PVEL Top Performer tests

YearProductTests
2023CS3W-xxxMSDHLID+LETIDPID

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — Canadian Solar

YearRecognition
2025Reliability High Achiever

Inverter compatibility & string sizing

Canadian Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.2 V
Voc when cold
per panel
33.4 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.2 / 33.4 V✗ Not a match: module voltage below MPPT range1.2
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.2 / 33.4 V✓ Within range0.58
Enphase IQ8M-72-2-US260–460 W60 V30–45 V52.2 / 33.4 V✓ Within range1.4
Enphase IQ8A-72-2-US295–500 W60 V32–45 V52.2 / 33.4 V✓ Within range1.3
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67676311,4396.08
Palmdale1,83583512,5246.69
Chula Vista1,69677211,5756.11
Huntington Beach1,64374811,2135.89
Riverside1,69677211,5756.21
Santa Clarita1,72478411,7666.28
747Jan747Feb959Mar1,059Apr1,046May1,112Jun1,171Jul1,185Aug1,036Sep914Oct786Nov680DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs CS3W-xxxMS panels in SoCal

building permits
6
Permits naming this series
Sep 2022 – Jul 2023
1
Jurisdictions so far
LA County (unincorp.) (6)

Permits over time

1Sep ’220Oct3Nov0Dec0Jan ’230Feb0Mar0Apr0May1Jun1Julpermits per month

Power class named in permit

455 W
5
445 W
1
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Microinverters

Enphase IQ8+
3
Number of permits naming both this panel series and the product; 5 of 6 permits list other equipment.

Compare with similar 455 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Canadian Solar CS3W-455MS455 W≥20.6%−0.32449.311.66product 20236
Hyundai Energy Solutions HiN-T450NF(BK)450 W≈23.2%−0.29839.214.53brand 5× (2017–2025)37
REC Group REC455AA Pure-RX455 W≈22.5%−0.24865.68.84brand 9× (2016–2025)33
Aptos Solar DNA-120-MF10-455W455 W≈21%−0.36341.513.93—22
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Canadian Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

CS6R-xxxMS-HL · 46CS3N-xxxMS · 46CS6.1-54TM-xxxH · 9CS1Y-xxxMS · 6CS3W-xxxMB-AG · 5CS7N-xxxMB-AG · 2

Questions & answers

How efficient is the Canadian Solar CS3W-455MS?

The Canadian Solar datasheet guarantees at least 20.6% module efficiency for the 455 W class (up to 21% for 465 W). 455 W over 2.14 m² equals about 213 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 763 kWh per year per 455 W panel in Los Angeles and about 835 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.2 V, Vmp at 74 °C cell = 33.4 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.2 V vs max input 60 V; Vmp when hot 33.4 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Has this panel been reliability-tested?

CS3W-xxxMS was a PVEL Top Performer in 2023 (DH, LID+LETID, PID).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — manufacturer datasheet “HiKu HIGH POWER MONO PERC MODULE CS3W-435|440|445|450|455|460|465MS”.
  3. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  4. Aptos Solar — datasheet Legacy Products.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2020–2026.
  6. RETC — PV Module Index report.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Sep 2022 – Jul 2023). Equipment matched from permit descriptions by model number.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).