Cali-GrafCali-Graf
Solar panelCanadian Solar

Canadian Solar CS3W-440MB-AG

144 half-cut cells, PERC, bifacial, 2.0 mm heat strengthened glass. Power classes 415–460 W in the CEC list.

CEC listed · Nov 23, 2020UL 61730Bifacial · 70%PERCInstalled in 5 SoCal permits
Power class
  • Power (STC)440 Wtolerance +10 / −0 W
  • Efficiency≈19.7%calculated from area
  • %/°C Pmax−0.35CEC test: −0.406
  • Degradation / yr0.45%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
CS3W-415MB-AG415 W47.7011.2239.7010.46≈18.6%385 WNov 23, 2020
CS3W-420MB-AG420 W47.9011.2739.9010.53≈18.8%389 WNov 23, 2020
CS3W-425MB-AG425 W48.1011.3240.1010.60≈19.0%394 WNov 23, 2020
CS3W-430MB-AG430 W48.3011.3740.3010.68≈19.2%399 WNov 23, 2020
CS3W-435MB-AG435 W48.5011.4240.5010.75≈19.5%404 WNov 23, 2020
CS3W-440MB-AG440 W48.7011.4840.7010.82≈19.7%408 WNov 23, 2020
CS3W-445MB-AG445 W48.9011.5440.9010.89≈19.9%413 WNov 23, 2020
CS3W-450MB-AG450 W49.1011.6041.1010.96≈20.1%418 WNov 23, 2020
CS3W-455MB-AG455 W49.3011.6641.3011.02≈20.4%423 WJul 12, 2021
CS3W-460MB-AG460 W49.5011.7241.5011.09≈20.6%428 WJul 12, 2021
≈ efficiency = Pmax ÷ panel area 2.234 m² (datasheet size).
CEC note: Formerly listed under Canadian Solar Inc.

Build & dimensions

Canadian Solar datasheet · Cali-Graf calculation

Heat & cold behaviour

Canadian Solar datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.35 %/°C−0.406 %/°C
Voc coefficient β−0.27 %/°C−0.310 %/°C
Isc coefficient α+0.05 %/°C+0.057 %/°C
Vmp coefficient≈ −0.40 %/°C—
Operating cell temperatureNMOT 41 ± 3 °CNOCT 43.4 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
415 W306.2 W37.2 V × 8.23 A80.2 W97%
420 W309.8 W37.39 V × 8.28 A81.1 W97%
425 W313.4 W37.58 V × 8.34 A82.1 W97%
430 W317.3 W37.77 V × 8.4 A83.1 W97%
435 W321 W37.95 V × 8.46 A84.1 W97%
440 W324.7 W38.14 V × 8.51 A85.1 W97%
445 W328.4 W38.33 V × 8.57 A86 W97%
450 W332.1 W38.51 V × 8.62 A87 W97%
455 W335.6 W38.7 V × 8.67 A87.9 W97%
460 W339.3 W38.89 V × 8.73 A88.9 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Bifacial performance

NLR SAM module library · Canadian Solar datasheet
Rear gain depends on mounting height and ground reflectance; flush roof mounts receive little rear light.

Certifications

CEC PV Module List (Oct 7, 2026) · Canadian Solar datasheet
UL 61730UL 1703IEC 61215IEC 61730IEC 61701IEC 62716IEC 60068MCSISO 14001ISO 45001ISO 9001

Warranty & degradation

Canadian Solar datasheet

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
5
PVEL Scorecards
Canadian Solar named Top Performer, 2020–2026
1
RETC PV Module Index
Canadian Solar, 2025
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Canadian Solar

YearRecognition
2025Reliability High Achiever

Inverter compatibility & string sizing

Canadian Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
51.7 V
Voc when cold
per panel
32.7 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V51.7 / 32.7 V✓ Within range1.52
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V51.7 / 32.7 V✗ Not a match: module voltage below MPPT range1.16
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V51.7 / 32.7 V✓ Within range0.56
Enphase IQ8M-72-2-US260–460 W60 V30–45 V51.7 / 32.7 V✓ Within range1.35
Enphase IQ8A-72-2-US295–500 W60 V32–45 V51.7 / 32.7 V✓ Within range1.26
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67673711,7996.08
Palmdale1,83580712,9186.69
Chula Vista1,69674611,9406.11
Huntington Beach1,64372311,5675.89
Riverside1,69674611,9406.21
Santa Clarita1,72475912,1376.28
770Jan771Feb989Mar1,093Apr1,079May1,147Jun1,208Jul1,222Aug1,069Sep943Oct810Nov701DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs CS3W-xxxMB-AG panels in SoCal

building permits · CSLB License Master
5
Permits naming this series
Aug 2022 – Oct 2024
1
Licensed installers
CSLB license on the permit
2
Jurisdictions so far
LA County (unincorp.) (3), Huntington Beach (2)

Permits over time

2Q3 ’221Q4 ’220Q1 ’230Q2 ’230Q3 ’230Q4 ’230Q1 ’240Q2 ’240Q3 ’242Q4 ’24permits per quarter

Power class named in permit

440 W
2
445 W
2
420 W
1
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Microinverters

Enphase IQ8+
2
Number of permits naming both this panel series and the product; 3 of 5 permits list other equipment.

Compare with similar 440 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizeWarrantyPVEL (product / brand)SoCal permits (series)
Canadian Solar CS3W-440MB-AG440 W≈19.7%−0.40648.711.4883.9 × 41.3 in—brand 5×5
Qcells Q.TRON BLK M-G2+ 440440 W≥22.5%−0.27639.8813.967.8 × 44.6 in25 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-440QD440 W≈22.6%−0.29438.9714.2567.8 × 44.6 in25 / 30 yrbrand 7× (2017–2025)39
Hyundai Energy Solutions HiN-T440NF(BK)440 W≈22.7%−0.29838.814.39—25 / 30 yrbrand 5× (2017–2025)37
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Canadian Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

CS6R-xxxMS-HL · 46CS3N-xxxMS · 46CS6.1-54TM-xxxH · 9CS1Y-xxxMS · 6CS3W-xxxMS · 6CS7N-xxxMB-AG · 2

Questions & answers

How efficient is the Canadian Solar CS3W-440MB-AG?

Calculated from the panel area (2.23 m²): about 19.7% for the 440 W class. 440 W over 2.23 m² equals about 197 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 737 kWh per year per 440 W panel in Los Angeles and about 807 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.35 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.7 V, Vmp at 74 °C cell = 32.7 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 51.7 V vs max input 60 V; Vmp when hot 32.7 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

How big and heavy is it?

83.9 × 41.3 × 1.18 in (2,132 × 1,048 × 30 mm), 62.6 lb (28.4 kg).

Is it bifacial?

Yes, bifaciality 70%. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Canadian Solar was named a Top Performer in 5 Scorecards (2020–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — manufacturer datasheet “BiHiKu SUPER HIGH POWER BIFACIAL MONO PERC MODULE UP TO 30% MORE POWER FROM THE BACK SIDE”.
  3. Canadian Solar — manufacturer datasheet “BiHiKu HIGH POWER BIFACIAL MONO PERC MODULE UP TO 30% MORE POWER FROM THE BACK SIDE”.
  4. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  5. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  6. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  7. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2020–2026.
  8. RETC — PV Module Index report.
  9. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  10. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  11. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  12. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Aug 2022 – Oct 2022); City of Huntington Beach (Oct 2024). Equipment matched from permit descriptions by model number.
  13. Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
  14. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).