144 half-cut cells, bifacial, transparent backsheet. 445 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| BRIGHTSPOT-445W-m72HBi | 445 W | 50.60 | 11.37 | 42.00 | 10.61 | ≈20.1% | 416 W | Apr 11, 2024 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.358 %/°C |
| Voc coefficient β | −0.295 %/°C |
| Isc coefficient α | +0.044 %/°C |
| Operating cell temperature | NOCT 43.8 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 445 W | 324.7 W | 38.2 V × 8.5 A | 84.7 W | 95% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 54 / 33.7 V | ✗ Not a match: module voltage below MPPT range | 1.17 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 54 / 33.7 V | ✓ Within range | 0.57 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 54 / 33.7 V | ✓ Within range | 1.37 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 54 / 33.7 V | ✓ Within range | 1.28 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 746 | 11,933 | 6.08 |
| Palmdale | 1,835 | 817 | 13,065 | 6.69 |
| Chula Vista | 1,696 | 755 | 12,076 | 6.11 |
| Huntington Beach | 1,643 | 731 | 11,698 | 5.89 |
| Riverside | 1,696 | 755 | 12,076 | 6.21 |
| Santa Clarita | 1,724 | 767 | 12,275 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | Warranty | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|---|
| Bright Spot Solar BRIGHTSPOT-445W-m72HBi | 445 W | ≈20.1% | −0.358 | 50.6 | 11.37 | — | — | — |
| Qcells Q.TRON BLK M-G2+ 445 | 445 W | ≈22.8% | −0.276 | 40.16 | 13.98 | 25 / 25 yr | brand 11× (2016–2026) | 40 |
| Silfab Solar SIL-440QD | 440 W | ≈22.6% | −0.294 | 38.97 | 14.25 | 25 / 30 yr | brand 7× (2017–2025) | 39 |
| Hyundai Energy Solutions HiN-T445NF(BK) | 445 W | ≈22.9% | −0.298 | 39 | 14.46 | 25 / 30 yr | brand 5× (2017–2025) | 37 |
Calculated from the panel area (2.21 m²): about 20.1% for the 445 W class. 445 W over 2.21 m² equals about 201 W per square meter.
PVWatts v8 with typical-year weather gives about 746 kWh per year per 445 W panel in Los Angeles and about 817 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.358 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.5% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 54 V, Vmp at 74 °C cell = 33.7 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 54 V vs max input 60 V; Vmp when hot 33.7 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.