Solar panelBoviet Solar

Boviet Solar BVM8611M-615R-H-HC-BF

132 half-cut cells, bifacial. Power classes 595–640 W in the CEC list.

CEC listed · Sep 2, 2025UL 61730Bifacial
Power class
  • Power (STC)615 WCEC nameplate
  • Efficiency≈24.4%calculated from area
  • %/°C Pmax−0.292CEC listing test
  • PTC / STC95.3%PTC 586 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
BVM8611M-595R-H-HC-BF595 W47.6515.6940.5414.68≈23.6%567 WSep 2, 2025
BVM8611M-600R-H-HC-BF600 W47.8515.7440.7414.73≈23.8%572 WSep 2, 2025
BVM8611M-605R-H-HC-BF605 W48.0515.7940.9414.78≈24.0%577 WSep 2, 2025
BVM8611M-610R-H-HC-BF610 W48.2515.8441.1414.83≈24.2%582 WSep 2, 2025
BVM8611M-615R-H-HC-BF615 W48.4515.8941.3414.88≈24.4%586 WSep 2, 2025
BVM8611M-620R-H-HC-BF620 W48.6515.9441.5414.93≈24.6%591 WSep 2, 2025
BVM8611M-625R-H-HC-BF625 W48.8515.9941.7314.98≈24.8%596 WSep 2, 2025
BVM8611M-630R-H-HC-BF630 W49.0516.0741.9215.03≈25.0%601 WSep 2, 2025
BVM8611M-635R-H-HC-BF635 W49.2516.1242.1215.09≈25.2%606 WSep 2, 2025
BVM8611M-640R-H-HC-BF640 W49.4516.1742.3115.14≈25.4%611 WSep 2, 2025
≈ efficiency = Pmax ÷ CEC-listed area 2.52 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.292 %/°C
Voc coefficient β−0.220 %/°C
Isc coefficient α+0.037 %/°C
Operating cell temperatureNOCT 43 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
595 W453.2 W38.88 V × 11.66 A116.2 W98%
600 W457 W39.07 V × 11.69 A117.2 W98%
605 W460.8 W39.27 V × 11.73 A118.2 W98%
610 W464.6 W39.46 V × 11.77 A119.2 W98%
615 W468.4 W39.65 V × 11.81 A120.2 W98%
620 W472.3 W39.84 V × 11.85 A121.1 W98%
625 W476 W40.02 V × 11.89 A122.1 W98%
630 W479.8 W40.21 V × 11.93 A123.1 W98%
635 W484 W40.4 V × 11.98 A124.2 W98%
640 W487.8 W40.58 V × 12.02 A125.1 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard
6
PVEL Scorecards
Boviet Solar named Top Performer, 2019–2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
50.9 V
Voc when cold
per panel
34.7 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,03111,3386.08
Palmdale1,8351,12912,4146.69
Chula Vista1,6961,04311,4736.11
Huntington Beach1,6431,01011,1155.89
Riverside1,6961,04311,4736.21
Santa Clarita1,7241,06011,6636.28
740Jan741Feb950Mar1,050Apr1,037May1,102Jun1,161Jul1,174Aug1,027Sep906Oct779Nov674DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 615 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · Waaree datasheet
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
Boviet Solar BVM8611M-615R-H-HC-BF615 W≈24.4%−0.29248.4515.89brand 6×
Phono Solar PS610M8GFH-24/TNH610 W≈23.8%−0.29353.814.02product 2024, 2025
ZNShine Solar ZXM7-UHLDD144-615/N615 W≈24%−0.28152.914.72product 2024, 2025, 2026
Waaree BiN-21-615615 W≥22.8%−0.28848.915.97product 2026
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Boviet Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits

Other series by SoCal permits

BVM6610M-xxxS-H-HC-BF · 1BVM7612M-xxx-H-HC-BFBVM7612M-xxx-H-HC-BF-DGBVM7613M-xxx-H-HC-BFBVM7613M-xxx-H-HC-BF-DGBVM7610M-xxx-H-HC-BF

Questions & answers

How efficient is the Boviet Solar BVM8611M-615R-H-HC-BF?

Calculated from the panel area (2.52 m²): about 24.4% for the 615 W class. 615 W over 2.52 m² equals about 244 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,031 kWh per year per 615 W panel in Los Angeles and about 1,129 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.292 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 50.9 V, Vmp at 74 °C cell = 34.7 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Boviet Solar was named a Top Performer in 6 Scorecards (2019–2024).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Waaree — datasheet ELITE-R-SERIES-BiN-21-600-635-WEL-EPD-600-635-132-BiN-HC.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2019–2024.
  4. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  6. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  7. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).