156 half-cut cells, bifacial. Power classes 570–650 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| BVM7613M-570-H-HC-BF | 570 W | 53.83 | 13.40 | 45.51 | 12.55 | ≈20.4% | 535 W | May 11, 2023 |
| BVM7613M-575-H-HC-BF | 575 W | 53.90 | 13.48 | 45.65 | 12.62 | ≈20.5% | 540 W | May 11, 2023 |
| BVM7613M-580-H-HC-BF | 580 W | 53.98 | 13.56 | 45.80 | 12.69 | ≈20.7% | 545 W | May 11, 2023 |
| BVM7613M-585-H-HC-BF | 585 W | 54.07 | 13.64 | 45.97 | 12.75 | ≈20.9% | 550 W | May 11, 2023 |
| BVM7613M-590-H-HC-BF | 590 W | 54.15 | 13.72 | 46.11 | 12.82 | ≈21.1% | 554 W | May 11, 2023 |
| BVM7613M-595-H-HC-BF | 595 W | 54.24 | 13.81 | 46.29 | 12.88 | ≈21.2% | 559 W | May 11, 2023 |
| BVM7613M-600-H-HC-BF | 600 W | 54.31 | 14.08 | 46.42 | 12.95 | ≈21.4% | 564 W | May 11, 2023 |
| BVM7613M-605-H-HC-BF | 605 W | 54.40 | 14.16 | 46.56 | 13.02 | ≈21.6% | 569 W | May 11, 2023 |
| BVM7613M-615-H-HC-BF | 615 W | 56.52 | 13.64 | 47.30 | 13.01 | ≈22.0% | 585 W | Jul 13, 2026 |
| BVM7613M-620-H-HC-BF | 620 W | 56.69 | 13.71 | 47.45 | 13.07 | ≈22.1% | 590 W | Jul 13, 2026 |
| BVM7613M-625-H-HC-BF | 625 W | 56.86 | 13.78 | 47.60 | 13.14 | ≈22.3% | 595 W | Jul 13, 2026 |
| BVM7613M-630-H-HC-BF | 630 W | 57.03 | 13.85 | 47.75 | 13.20 | ≈22.5% | 600 W | Jul 13, 2026 |
| BVM7613M-635-H-HC-BF | 635 W | 57.20 | 13.92 | 47.90 | 13.26 | ≈22.7% | 604 W | Jul 13, 2026 |
| BVM7613M-640-H-HC-BF | 640 W | 57.37 | 13.99 | 48.05 | 13.32 | ≈22.9% | 609 W | Jul 13, 2026 |
| BVM7613M-645-H-HC-BF | 645 W | 57.54 | 14.06 | 48.20 | 13.39 | ≈23.0% | 614 W | Jul 13, 2026 |
| BVM7613M-650-H-HC-BF | 650 W | 57.71 | 14.13 | 48.34 | 13.45 | ≈23.2% | 619 W | Jul 13, 2026 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.358 %/°C |
| Voc coefficient β | −0.264 %/°C |
| Isc coefficient α | +0.033 %/°C |
| Operating cell temperature | NOCT 42.8 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 570 W | 424.2 W | 41.66 V × 10.18 A | 114 W | 100% |
| 575 W | 427.9 W | 41.78 V × 10.24 A | 115 W | 100% |
| 580 W | 431.7 W | 41.92 V × 10.3 A | 116.1 W | 100% |
| 585 W | 435.4 W | 42.08 V × 10.35 A | 117 W | 100% |
| 590 W | 439.1 W | 42.2 V × 10.4 A | 118 W | 100% |
| 595 W | 442.9 W | 42.37 V × 10.45 A | 119 W | 100% |
| 600 W | 446.5 W | 42.49 V × 10.51 A | 120 W | 100% |
| 605 W | 450.3 W | 42.62 V × 10.57 A | 121 W | 100% |
| 615 W | 467 W | 45.71 V × 10.22 A | 117 W | 95% |
| 620 W | 470.7 W | 45.85 V × 10.27 A | 118 W | 95% |
| 625 W | 474.7 W | 45.99 V × 10.32 A | 119 W | 95% |
| 630 W | 478.3 W | 46.14 V × 10.37 A | 119.9 W | 95% |
| 635 W | 482 W | 46.28 V × 10.41 A | 120.8 W | 95% |
| 640 W | 485.7 W | 46.43 V × 10.46 A | 121.7 W | 95% |
| 645 W | 489.8 W | 46.57 V × 10.52 A | 122.8 W | 95% |
| 650 W | 493.4 W | 46.71 V × 10.56 A | 123.7 W | 95% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–10 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–10 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–10 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–8 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 1,014 | 12,168 | 6.08 |
| Palmdale | 1,835 | 1,110 | 13,322 | 6.69 |
| Chula Vista | 1,696 | 1,026 | 12,313 | 6.11 |
| Huntington Beach | 1,643 | 994 | 11,928 | 5.89 |
| Riverside | 1,696 | 1,026 | 12,313 | 6.21 |
| Santa Clarita | 1,724 | 1,043 | 12,516 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Boviet Solar BVM7613M-605-H-HC-BF | 605 W | ≈21.6% | −0.358 | 54.4 | 14.16 | brand 6× | — |
| Phono Solar PS605M8GFH-24/TNH | 605 W | ≈23.6% | −0.293 | 53.6 | 13.96 | product 2024, 2025 | 1 |
| Qcells Q.PEAK DUO XL-G11S.3/BFG 600 | 600 W | ≈22.1% | −0.348 | 53.66 | 13.8 | product 2024, 2025, 2026 | 1 |
| VSUN (Vietnam Sunergy) VSUN600N-144MH | 600 W | ≈23.3% | −0.309 | 52.9 | 14.03 | brand 6× (2021–2026) | 1 |
Calculated from the panel area (2.8 m²): about 21.6% for the 605 W class. 605 W over 2.8 m² equals about 216 W per square meter.
PVWatts v8 with typical-year weather gives about 1,014 kWh per year per 605 W panel in Los Angeles and about 1,110 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.358 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.5% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 57.7 V, Vmp at 74 °C cell = 37.6 V). Final design must follow the inverter manual and NEC 690.7.
Yes. Rear gain depends on mounting height and ground reflectance.
This exact series is not in published PVEL Top Performer tables; Boviet Solar was named a Top Performer in 6 Scorecards (2019–2024).