72 cells, bifacial, glass (dual-glass module). Power classes 375–410 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| BVM6612M-375L-H-BF-DG | 375 W | 47.95 | 10.11 | 39.22 | 9.58 | ≈18.6% | 351 W | Oct 1, 2020 |
| BVM6612M-380L-H-BF-DG | 380 W | 48.25 | 10.19 | 39.41 | 9.66 | ≈18.8% | 356 W | Oct 1, 2020 |
| BVM6612M-385L-H-BF-DG | 385 W | 48.45 | 10.26 | 39.60 | 9.74 | ≈19.1% | 360 W | Oct 1, 2020 |
| BVM6612M-390L-H-BF-DG | 390 W | 48.65 | 10.33 | 39.79 | 9.82 | ≈19.3% | 365 W | Oct 1, 2020 |
| BVM6612M-395L-H-BF-DG | 395 W | 48.85 | 10.42 | 39.97 | 9.90 | ≈19.6% | 370 W | Oct 1, 2020 |
| BVM6612M-400L-H-BF-DG | 400 W | 49.15 | 10.45 | 40.16 | 9.98 | ≈19.8% | 375 W | Oct 1, 2020 |
| BVM6612M-405L-H-BF-DG | 405 W | 49.45 | 10.49 | 40.33 | 10.06 | ≈20.0% | 380 W | Oct 1, 2020 |
| BVM6612M-410L-H-BF-DG | 410 W | 49.75 | 10.51 | 40.50 | 10.14 | ≈20.3% | 384 W | Oct 1, 2020 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.367 %/°C |
| Voc coefficient β | −0.294 %/°C |
| Isc coefficient α | +0.017 %/°C |
| Operating cell temperature | NOCT 42.7 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 375 W | 279.7 W | 38.09 V × 7.34 A | 71.6 W | 95% |
| 380 W | 283.4 W | 38.27 V × 7.41 A | 72.5 W | 95% |
| 385 W | 287.2 W | 38.46 V × 7.47 A | 73.5 W | 95% |
| 390 W | 290.9 W | 38.64 V × 7.53 A | 74.5 W | 95% |
| 395 W | 294.6 W | 38.81 V × 7.59 A | 75.4 W | 95% |
| 400 W | 298.4 W | 39 V × 7.65 A | 76.4 W | 95% |
| 405 W | 302.1 W | 39.16 V × 7.71 A | 77.3 W | 95% |
| 410 W | 305.8 W | 39.33 V × 7.77 A | 78.3 W | 95% |
| Year | Product | Tests |
|---|---|---|
| 2021 | BVM6612M-xxxL-H-BF-DG | DHMSSPANPIDTC |
| 2021 | BVM6612M-xxxL-H-BF (closely related product name) | MSSPID |
| 2021 | BVM6612M-xxxL-H (closely related product name) | LID+LETID |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 51.9 / 32.3 V | ✓ Within range | 1.34 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 51.9 / 32.3 V | ✗ Not a match: module voltage below MPPT range | 1.03 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 51.9 / 32.3 V | ✓ Within range | 0.5 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 51.9 / 32.3 V | ✓ Within range | 1.2 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 51.9 / 32.3 V | ✓ Within range | 1.12 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 654 | 11,766 | 6.08 |
| Palmdale | 1,835 | 716 | 12,882 | 6.69 |
| Chula Vista | 1,696 | 661 | 11,906 | 6.11 |
| Huntington Beach | 1,643 | 641 | 11,534 | 5.89 |
| Riverside | 1,696 | 661 | 11,906 | 6.21 |
| Santa Clarita | 1,724 | 672 | 12,102 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Boviet Solar BVM6612M-390L-H-BF-DG | 390 W | ≈19.3% | −0.367 | 48.65 | 10.33 | product 2021 | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 390 | 390 W | ≥19.9% | −0.362 | 45.23 | 11.07 | product 2022, 2023 | 221 |
| JA Solar JAM54S31-390/MR | 390 W | ≈20.5% | −0.329 | 36.85 | 13.61 | product 2023, 2024 | 152 |
| REC Group REC390AA Pure | 390 W | ≈21.8% | −0.256 | 48.6 | 10.19 | brand 9× (2016–2025) | 66 |
Calculated from the panel area (2.02 m²): about 19.3% for the 390 W class. 390 W over 2.02 m² equals about 193 W per square meter.
PVWatts v8 with typical-year weather gives about 654 kWh per year per 390 W panel in Los Angeles and about 716 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.367 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.9 V, Vmp at 74 °C cell = 32.3 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the Enphase datasheet: Voc when cold 51.9 V vs max input 60 V; Vmp when hot 32.3 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.
BVM6612M-xxxL-H-BF-DG was a PVEL Top Performer in 2021 (DH, MSS, PAN, PID, TC).