72 cells. Power classes 360–400 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| BVM6612M-360-H | 360 W | 47.50 | 9.68 | 38.82 | 9.29 | ≈18.6% | 335 W | Feb 11, 2020 |
| BVM6612M-365-H | 365 W | 47.60 | 9.79 | 38.90 | 9.40 | ≈18.8% | 340 W | Feb 11, 2020 |
| BVM6612M-370-H | 370 W | 47.70 | 9.89 | 39.02 | 9.50 | ≈19.1% | 344 W | Feb 11, 2020 |
| BVM6612M-375-H | 375 W | 48.00 | 9.96 | 39.22 | 9.58 | ≈19.3% | 349 W | Feb 11, 2020 |
| BVM6612M-380-H | 380 W | 48.30 | 10.04 | 39.41 | 9.66 | ≈19.6% | 354 W | Feb 11, 2020 |
| BVM6612M-385-H | 385 W | 48.50 | 10.11 | 39.60 | 9.74 | ≈19.8% | 359 W | Feb 11, 2020 |
| BVM6612M-390-H | 390 W | 48.70 | 10.18 | 39.79 | 9.82 | ≈20.1% | 363 W | Feb 11, 2020 |
| BVM6612M-395-H | 395 W | 48.90 | 10.27 | 39.98 | 9.90 | ≈20.4% | 368 W | Feb 11, 2020 |
| BVM6612M-400-H | 400 W | 49.20 | 10.30 | 40.16 | 9.98 | ≈20.6% | 373 W | Feb 11, 2020 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.382 %/°C |
| Voc coefficient β | −0.300 %/°C |
| Isc coefficient α | +0.039 %/°C |
| Operating cell temperature | NOCT 43.5 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 360 W | 266.2 W | 36.44 V × 7.31 A | 70.5 W | 98% |
| 365 W | 269.8 W | 36.51 V × 7.39 A | 71.4 W | 98% |
| 370 W | 273.1 W | 36.59 V × 7.46 A | 72.3 W | 98% |
| 375 W | 276.8 W | 36.82 V × 7.52 A | 73.3 W | 98% |
| 380 W | 280.8 W | 37.05 V × 7.58 A | 74.3 W | 98% |
| 385 W | 283.9 W | 37.2 V × 7.63 A | 75.2 W | 98% |
| 390 W | 287 W | 37.36 V × 7.68 A | 76 W | 97% |
| 395 W | 290.8 W | 37.51 V × 7.75 A | 77 W | 97% |
| 400 W | 293.4 W | 37.74 V × 7.77 A | 77.7 W | 97% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 51.6 / 31.3 V | ✓ Within range | 1.31 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 51.6 / 31.3 V | ✗ Not a match: module voltage below MPPT range | 1 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 51.6 / 31.3 V | ✓ Within range | 0.49 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 51.6 / 31.3 V | ✓ Within range | 1.17 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 51.6 / 31.3 V | ⚠ Works; below MPPT at peak heat | 1.09 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 637 | 11,464 | 6.08 |
| Palmdale | 1,835 | 697 | 12,551 | 6.69 |
| Chula Vista | 1,696 | 644 | 11,601 | 6.11 |
| Huntington Beach | 1,643 | 624 | 11,238 | 5.89 |
| Riverside | 1,696 | 644 | 11,601 | 6.21 |
| Santa Clarita | 1,724 | 655 | 11,792 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Boviet Solar BVM6612M-380-H | 380 W | ≈19.6% | −0.382 | 48.3 | 10.04 | brand 6× | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 380 | 380 W | ≈19.4% | −0.362 | 45.16 | 11.01 | product 2022, 2023 | 221 |
| JA Solar JAM54S31-385/MR | 385 W | ≈20.3% | −0.329 | 36.71 | 13.52 | product 2023, 2024 | 152 |
| REC Group REC380AA Pure | 380 W | ≈21.2% | −0.256 | 48.4 | 10.17 | brand 9× (2016–2025) | 66 |
Calculated from the panel area (1.94 m²): about 19.6% for the 380 W class. 380 W over 1.94 m² equals about 196 W per square meter.
PVWatts v8 with typical-year weather gives about 637 kWh per year per 380 W panel in Los Angeles and about 697 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.382 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.8% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.6 V, Vmp at 74 °C cell = 31.3 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the Enphase datasheet: Voc when cold 51.6 V vs max input 60 V; Vmp when hot 31.3 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
This exact series is not in published PVEL Top Performer tables; Boviet Solar was named a Top Performer in 6 Scorecards (2019–2024).