120 half-cut cells, bifacial. Power classes 355–380 W in the CEC list; datasheet covers 360–370 W.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| BVM6610M-355S-H-HC-BF | 355 W | 40.02 | 11.29 | 33.23 | 10.70 | ≈19.0% | 333 W | Jul 1, 2021 |
| BVM6610M-360S-H-HC-BF | 360 W | 40.21 | 11.37 | 33.45 | 10.78 | ≥19.2% | 338 W | Jul 1, 2021 |
| BVM6610M-365S-H-HC-BF | 365 W | 40.38 | 11.46 | 33.63 | 10.87 | ≥19.5% | 343 W | Jul 1, 2021 |
| BVM6610M-370S-H-HC-BF | 370 W | 40.56 | 11.54 | 33.81 | 10.96 | ≥19.7% | 348 W | Jul 1, 2021 |
| BVM6610M-375S-H-HC-BF | 375 W | 40.75 | 11.62 | 33.96 | 11.06 | ≈20.1% | 353 W | Jul 1, 2021 |
| BVM6610M-380S-H-HC-BF | 380 W | 40.94 | 11.73 | 34.17 | 11.14 | ≈20.3% | 357 W | Jul 1, 2021 |
| Datasheet | CEC listing test | |
|---|---|---|
| Pmax coefficient γ | −0.40 %/°C | −0.349 %/°C |
| Voc coefficient β | −0.31 %/°C | −0.298 %/°C |
| Isc coefficient α | +0.06 %/°C | +0.050 %/°C |
| Vmp coefficient | ≈ −0.46 %/°C | — |
| Operating cell temperature | NMOT 45 ± 35 °C | NOCT 42.8 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 355 W | 263.4 W | 31.05 V × 8.48 A | 69.2 W | 98% |
| 360 W | 267.1 W | 31.26 V × 8.55 A | 70.2 W | 98% |
| 365 W | 270.8 W | 31.42 V × 8.62 A | 71.2 W | 98% |
| 370 W | 274.5 W | 31.59 V × 8.69 A | 72.2 W | 98% |
| 375 W | 278.2 W | 31.73 V × 8.77 A | 73.1 W | 98% |
| 380 W | 282 W | 31.93 V × 8.83 A | 74.1 W | 98% |
| Year | Product | Tests |
|---|---|---|
| 2022 | BVM6610M-xxxS-H-HC-BF | LID+LETIDTC |
| 2022 | BVM6610M-xxxS-H-HC-BF-DG (closely related product name) | DHLID+LETIDMSSPANPIDTC |
| 2023 | BVM6610M-xxxS-H-HC-BF-DG (closely related product name) | PID |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–13 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 4–13 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–13 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–11 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 43.5 / 26.2 V | ⚠ Works; below MPPT at peak heat | 1.28 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 43.5 / 26.2 V | ✗ Not a match: module voltage below MPPT range | 0.97 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 43.5 / 26.2 V | ⚠ Works; below MPPT at peak heat | 0.47 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 43.5 / 26.2 V | ⚠ Works; below MPPT at peak heat | 1.14 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 43.5 / 26.2 V | ⚠ Works; below MPPT at peak heat | 1.06 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 620 | 11,782 | 6.08 |
| Palmdale | 1,835 | 679 | 12,900 | 6.69 |
| Chula Vista | 1,696 | 628 | 11,923 | 6.11 |
| Huntington Beach | 1,643 | 608 | 11,550 | 5.89 |
| Riverside | 1,696 | 628 | 11,923 | 6.21 |
| Santa Clarita | 1,724 | 638 | 12,120 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Boviet Solar BVM6610M-370S-H-HC-BF | 370 W | ≥19.7% | −0.349 | 40.56 | 11.54 | product 2022 | 1 |
| LONGi LR4-60HPB-370M | 370 W | ≈20.9% | −0.339 | 41.2 | 11.5 | product 2021, 2022 | 193 |
| Canadian Solar CS3N-375MS {Blk} | 375 W | ≈19% | −0.342 | 43.5 | 11.2 | product 2023 | 46 |
| REC Group REC370AA | 370 W | ≈21.9% | −0.258 | 44.1 | 10.55 | brand 9× (2016–2025) | 30 |
The Boviet Solar datasheet guarantees at least 19.7% module efficiency for the 370 W class. 370 W over 1.87 m² equals about 198 W per square meter.
PVWatts v8 with typical-year weather gives about 620 kWh per year per 370 W panel in Los Angeles and about 679 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.40 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.7% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.5 V, Vmp at 74 °C cell = 26.2 V). Final design must follow the inverter manual and NEC 690.7.
12 years on the product and 25 years linear on performance (manufacturer datasheet).
Yes. Rear gain depends on mounting height and ground reflectance.
BVM6610M-xxxS-H-HC-BF was a PVEL Top Performer in 2022 (LID+LETID, TC).