Cali-GrafCali-Graf
Solar panelBoviet Solar

Boviet Solar BVM6610M-370S-H-HC-BF

120 half-cut cells, bifacial. Power classes 355–380 W in the CEC list; datasheet covers 360–370 W.

CEC listed · Jul 1, 2021UL 61730Bifacial12-yr product + 25-yr performance warrantyPVEL Top Performer 2022Seen in 1 SoCal permit
Power class
  • Power (STC)370 Wtolerance +5 / −0 W
  • Efficiency≥19.7%datasheet minimum
  • %/°C Pmax−0.40CEC test: −0.349
  • Degradation / yr0.6%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · Boviet Solar datasheet · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
BVM6610M-355S-H-HC-BF355 W40.0211.2933.2310.70≈19.0%333 WJul 1, 2021
BVM6610M-360S-H-HC-BF360 W40.2111.3733.4510.78≥19.2%338 WJul 1, 2021
BVM6610M-365S-H-HC-BF365 W40.3811.4633.6310.87≥19.5%343 WJul 1, 2021
BVM6610M-370S-H-HC-BF370 W40.5611.5433.8110.96≥19.7%348 WJul 1, 2021
BVM6610M-375S-H-HC-BF375 W40.7511.6233.9611.06≈20.1%353 WJul 1, 2021
BVM6610M-380S-H-HC-BF380 W40.9411.7334.1711.14≈20.3%357 WJul 1, 2021
≈ efficiency = Pmax ÷ CEC-listed area 1.87 m² for classes outside the datasheet.

Build & dimensions

CEC PV Module List (Oct 7, 2026) · Boviet Solar datasheet

Heat & cold behaviour

Boviet Solar datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.40 %/°C−0.349 %/°C
Voc coefficient β−0.31 %/°C−0.298 %/°C
Isc coefficient α+0.06 %/°C+0.050 %/°C
Vmp coefficient≈ −0.46 %/°C—
Operating cell temperatureNMOT 45 ± 35 °CNOCT 42.8 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
355 W263.4 W31.05 V × 8.48 A69.2 W98%
360 W267.1 W31.26 V × 8.55 A70.2 W98%
365 W270.8 W31.42 V × 8.62 A71.2 W98%
370 W274.5 W31.59 V × 8.69 A72.2 W98%
375 W278.2 W31.73 V × 8.77 A73.1 W98%
380 W282 W31.93 V × 8.83 A74.1 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Boviet Solar datasheet
Packaging: 30 per pallet · 720 per container

Certifications

CEC PV Module List (Oct 7, 2026) · Boviet Solar datasheet
UL 61730IEC 61215IEC 61730MCSISO 14001ISO 45001ISO 9001

Warranty & degradation

Boviet Solar datasheet · Cali-Graf calculation
75%81%88%94%100%051015202597.5% yr 192.1% yr 1083.1% yr 25years
  • Product warranty12 years
  • Performance warranty25 years, linear
  • Year 1≥ 97.5%
  • Then≤ 0.6% / year
  • Year 10≥ 92.1%calculated from warranty terms

Independent reliability testing

Kiwa PVEL Scorecard
2022, 2023
PVEL Top Performer
this series
6
Tests passed as Top Performer
DH, LID+LETID, MSS, PAN, PID, TC
6
PVEL Scorecards
Boviet Solar named Top Performer, 2019–2024

PVEL Top Performer tests

YearProductTests
2022BVM6610M-xxxS-H-HC-BFLID+LETIDTC
2022BVM6610M-xxxS-H-HC-BF-DG (closely related product name)DHLID+LETIDMSSPANPIDTC
2023BVM6610M-xxxS-H-HC-BF-DG (closely related product name)PID

Tested bill of materials

Details describe the tested sample, not every module of the series.

Inverter compatibility & string sizing

Boviet Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.5 V
Voc when cold
per panel
26.2 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.5 / 26.2 V⚠ Works; below MPPT at peak heat1.28
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.5 / 26.2 V✗ Not a match: module voltage below MPPT range0.97
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.5 / 26.2 V⚠ Works; below MPPT at peak heat0.47
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.5 / 26.2 V⚠ Works; below MPPT at peak heat1.14
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.5 / 26.2 V⚠ Works; below MPPT at peak heat1.06
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67662011,7826.08
Palmdale1,83567912,9006.69
Chula Vista1,69662811,9236.11
Huntington Beach1,64360811,5505.89
Riverside1,69662811,9236.21
Santa Clarita1,72463812,1206.28
769Jan770Feb988Mar1,091Apr1,078May1,145Jun1,206Jul1,220Aug1,067Sep941Oct809Nov700DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 370 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · Canadian Solar datasheet · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Boviet Solar BVM6610M-370S-H-HC-BF370 W≥19.7%−0.34940.5611.54product 20221
LONGi LR4-60HPB-370M370 W≈20.9%−0.33941.211.5product 2021, 2022193
Canadian Solar CS3N-375MS {Blk}375 W≈19%−0.34243.511.2product 202346
REC Group REC370AA370 W≈21.9%−0.25844.110.55brand 9× (2016–2025)30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Boviet Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard

Other series by SoCal permits

BVM7612M-xxx-H-HC-BFBVM7612M-xxx-H-HC-BF-DGBVM7613M-xxx-H-HC-BFBVM7613M-xxx-H-HC-BF-DGBVM7610M-xxx-H-HC-BFBVM8611M-xxx-H-HC-BF

Questions & answers

How efficient is the Boviet Solar BVM6610M-370S-H-HC-BF?

The Boviet Solar datasheet guarantees at least 19.7% module efficiency for the 370 W class. 370 W over 1.87 m² equals about 198 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 620 kWh per year per 370 W panel in Los Angeles and about 679 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.40 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.5 V, Vmp at 74 °C cell = 26.2 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

12 years on the product and 25 years linear on performance (manufacturer datasheet).

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

BVM6610M-xxxS-H-HC-BF was a PVEL Top Performer in 2022 (LID+LETID, TC).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Boviet Solar — manufacturer datasheet “Bifacial Module 360-370W(9BB) Advancing the Power of the Sun”.
  3. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2019–2024.
  5. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Oct 2022). Equipment matched from permit descriptions by model number.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).