144 half-cut cells, bifacial, glass (dual-glass module). Power classes 580–610 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| BSM580M10-72HNH | 580 W | 52.00 | 13.80 | 44.00 | 13.17 | ≈22.5% | 551 W | May 12, 2025 |
| BSM585M10-72HNH | 585 W | 52.20 | 13.85 | 44.20 | 13.23 | ≈22.7% | 556 W | May 12, 2025 |
| BSM585M10-72HNH | 585 W | 51.20 | 14.55 | 42.50 | 13.76 | ≈22.9% | 556 W | Apr 22, 2024 |
| BSM590M10-72HNH | 590 W | 52.40 | 13.90 | 44.40 | 13.29 | ≈22.9% | 560 W | May 12, 2025 |
| BSM590M10-72HNH | 590 W | 51.30 | 14.63 | 42.70 | 13.83 | ≈23.0% | 561 W | Apr 22, 2024 |
| BSM595M10-72HNH | 595 W | 52.50 | 13.95 | 44.60 | 13.35 | ≈23.1% | 565 W | May 12, 2025 |
| BSM600M10-72HNH | 600 W | 52.70 | 14.00 | 44.80 | 13.41 | ≈23.3% | 570 W | May 12, 2025 |
| BSM605M10-72HNH | 605 W | 52.90 | 14.05 | 44.90 | 13.47 | ≈23.4% | 575 W | May 12, 2025 |
| BSM610M10-72HNH | 610 W | 53.10 | 14.10 | 45.10 | 13.53 | ≈23.6% | 580 W | May 12, 2025 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.301 %/°C |
| Voc coefficient β | −0.218 %/°C |
| Isc coefficient α | +0.048 %/°C |
| Operating cell temperature | NOCT 43.2 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 580 W | 437 W | 41.3 V × 10.58 A | 113.2 W | 98% |
| 585 W | 441.1 W | 41.5 V × 10.63 A | 114.1 W | 98% |
| 585 W | 438.4 W | 41.2 V × 10.64 A | 110.3 W | 94% |
| 590 W | 444.3 W | 41.6 V × 10.68 A | 115 W | 97% |
| 590 W | 443 W | 41.4 V × 10.7 A | 111.1 W | 94% |
| 595 W | 448.1 W | 41.8 V × 10.72 A | 115.9 W | 97% |
| 600 W | 452.3 W | 42 V × 10.77 A | 116.9 W | 97% |
| 605 W | 456.6 W | 42.2 V × 10.82 A | 117.8 W | 97% |
| 610 W | 459.8 W | 42.3 V × 10.87 A | 119.1 W | 98% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–10 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–10 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–10 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 989 | 11,866 | 6.08 |
| Palmdale | 1,835 | 1,083 | 12,992 | 6.69 |
| Chula Vista | 1,696 | 1,001 | 12,008 | 6.11 |
| Huntington Beach | 1,643 | 969 | 11,632 | 5.89 |
| Riverside | 1,696 | 1,001 | 12,008 | 6.21 |
| Santa Clarita | 1,724 | 1,017 | 12,206 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Bluesun BSM590M10-72HNH | 590 W | ≈22.9% | −0.301 | 52.4 | 13.9 | — | — |
| Phono Solar PS590M8GFH-24/TNH | 590 W | ≈23% | −0.293 | 53 | 13.78 | product 2024, 2025 | 1 |
| Qcells Q.PEAK DUO XL-G11S.3/BFG 590 | 590 W | ≈21.7% | −0.348 | 53.6 | 13.74 | product 2024, 2025, 2026 | 1 |
| VSUN (Vietnam Sunergy) VSUN590N-144MH | 590 W | ≈22.9% | −0.309 | 52.48 | 13.93 | brand 6× (2021–2026) | 1 |
Calculated from the panel area (2.58 m²): about 22.9% for the 590 W class. 590 W over 2.58 m² equals about 229 W per square meter.
PVWatts v8 with typical-year weather gives about 989 kWh per year per 590 W panel in Los Angeles and about 1,083 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.301 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.6% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 55 V, Vmp at 74 °C cell = 36.8 V). Final design must follow the inverter manual and NEC 690.7.
Yes. Rear gain depends on mounting height and ground reflectance.