Cali-GrafCali-Graf
Solar panelBluesun

Bluesun BSM415M10-54HPH

108 half-cut cells, PERC. Power classes 395–415 W in the CEC list; datasheet covers 400–420 W.

CEC listed · Aug 22, 2022UL 61730PERCMade In Thailand
Power class
  • Power (STC)415 WCEC nameplate
  • Efficiency≥21.2%datasheet minimum
  • %/°C Pmax−0.35CEC test: −0.358
  • PTC / STC93.3%PTC 387 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · Bluesun datasheet · 5 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
BSM395M10-54HPH395 W36.7513.6930.8512.81≈20.2%368 WAug 22, 2022
BSM400M10-54HPH400 W37.0013.7831.0512.89≥20.5%373 WAug 22, 2022
BSM405M10-54HPH405 W37.2513.8631.2412.97≥20.7%378 WAug 22, 2022
BSM410M10-54HPH410 W37.5013.9431.4313.05≥21.0%382 WAug 22, 2022
BSM415M10-54HPH415 W37.7514.0231.6413.13≥21.2%387 WAug 22, 2022
≈ efficiency = Pmax ÷ panel area 1.953 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

Bluesun datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

Bluesun datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.35 %/°C−0.358 %/°C
Voc coefficient β—−0.279 %/°C
Isc coefficient α+0.05 %/°C+0.051 %/°C
Vmp coefficient≈ −0.40 %/°C—
Operating cell temperature—NOCT 44.8 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NMOT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
400 W298.034.8011.1129.0010.30
405 W302.035.1011.1729.2010.36
410 W306.035.3011.2429.3010.42
415 W309.035.6011.3129.5010.49

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
395 W286.6 W27.77 V × 10.32 A75.7 W96%
400 W290.3 W27.95 V × 10.39 A76.6 W96%
405 W293.9 W28.12 V × 10.45 A77.6 W96%
410 W297.5 W28.29 V × 10.52 A78.5 W96%
415 W301.3 W28.48 V × 10.58 A79.5 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Bluesun datasheet
Packaging: 36 per pallet · 936 per container

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
40.2 V
Voc when cold
per panel
25.5 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V40.2 / 25.5 V⚠ Works; below MPPT at peak heat1.43
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V40.2 / 25.5 V✗ Not a match: module voltage below MPPT range1.09
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V40.2 / 25.5 V⚠ Works; below MPPT at peak heat0.53
Enphase IQ8M-72-2-US260–460 W60 V30–45 V40.2 / 25.5 V⚠ Works; below MPPT at peak heat1.28
Enphase IQ8A-72-2-US295–500 W60 V32–45 V40.2 / 25.5 V✗ Not a match: module voltage below MPPT range1.19
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67669611,8246.08
Palmdale1,83576212,9466.69
Chula Vista1,69670411,9656.11
Huntington Beach1,64368211,5915.89
Riverside1,69670411,9656.21
Santa Clarita1,72471512,1636.28
772Jan773Feb991Mar1,095Apr1,082May1,149Jun1,211Jul1,225Aug1,071Sep945Oct812Nov703DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 415 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Bluesun BSM415M10-54HPH415 W≥21.2%−0.35837.7514.02——
Qcells Q.PEAK DUO BLK ML-G10+ 415415 W≈21.1%−0.33745.4111.23product 2022, 2023221
REC Group REC410AA Pure410 W≈22.9%−0.2564910.35brand 9× (2016–2025)66
LONGi LR5-54HABB-415M415 W≈21.8%−0.34237.7713.94brand 9× (2017–2026)64
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Bluesun BSM415M10-54HPH?

The Bluesun datasheet guarantees at least 21.2% module efficiency for the 415 W class. 415 W over 1.95 m² equals about 212 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 696 kWh per year per 415 W panel in Los Angeles and about 762 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.35 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 40.2 V, Vmp at 74 °C cell = 25.5 V). Final design must follow the inverter manual and NEC 690.7.

How big and heavy is it?

67.8 × 44.6 × 1.18 in (1,722 × 1,134 × 30 mm), 47.4 lb (21.5 kg).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Bluesun — manufacturer datasheet “NEW HEX5 BSM415M10-54HPH”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).