Cali-GrafCali-Graf
Solar panelBluesun

Bluesun BSM460M-72HBD

144 half-cut cells, PERC, bifacial. Power classes 435–460 W in the CEC list.

CEC listed · Jul 21, 2021UL 61730BifacialPERCMade In ThailandSeen in 1 SoCal permit
Power class
  • Power (STC)460 WCEC nameplate
  • Efficiency≈21.2%calculated from area
  • %/°C Pmax−0.377CEC listing test
  • PTC / STC92.8%PTC 427 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
BSM435M-72HBD435 W49.8011.1641.4010.51≈20.0%403 WJul 21, 2021
BSM440M-72HBD440 W50.0011.2241.6010.58≈20.2%408 WJul 21, 2021
BSM445M-72HBD445 W50.2011.2941.8010.65≈20.5%412 WJul 21, 2021
BSM450M-72HBD450 W50.4011.3642.0010.72≈20.7%417 WJul 21, 2021
BSM455M-72HBD455 W50.6011.4342.2010.79≈20.9%422 WJul 21, 2021
BSM460M-72HBD460 W50.8011.5042.4010.86≈21.2%427 WJul 21, 2021
≈ efficiency = Pmax ÷ panel area 2.174 m² (datasheet size).

Build & dimensions

Bluesun datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.377 %/°C
Voc coefficient β−0.298 %/°C
Isc coefficient α+0.075 %/°C
Operating cell temperatureNOCT 45.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
435 W324.1 W37.17 V × 8.72 A82.9 W95%
440 W327.8 W37.35 V × 8.78 A83.9 W95%
445 W331.6 W37.53 V × 8.84 A84.8 W95%
450 W335.4 W37.71 V × 8.89 A85.8 W95%
455 W339.2 W37.89 V × 8.95 A86.8 W95%
460 W343 W38.07 V × 9.01 A87.8 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
54.3 V
Voc when cold
per panel
33 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V54.3 / 33 V✗ Not a match: module voltage below MPPT range1.21
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V54.3 / 33 V✓ Within range0.59
Enphase IQ8M-72-2-US260–460 W60 V30–45 V54.3 / 33 V✓ Within range1.42
Enphase IQ8A-72-2-US295–500 W60 V32–45 V54.3 / 33 V✓ Within range1.32
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67677111,5646.08
Palmdale1,83584412,6626.69
Chula Vista1,69678011,7026.11
Huntington Beach1,64375611,3375.89
Riverside1,69678011,7026.21
Santa Clarita1,72479311,8966.28
755Jan756Feb969Mar1,071Apr1,058May1,124Jun1,184Jul1,198Aug1,047Sep924Oct794Nov687DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 460 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizeSoCal permits (series)
Bluesun BSM460M-72HBD460 W≈21.2%−0.37750.811.582.4 × 40.9 in1
REC Group REC460AA Pure-RX460 W≈22.8%−0.24865.38.88—33
Aptos Solar DNA-120-MF10-460W460 W≈21.3%−0.36341.71475.1 × 44.6 in22
Canadian Solar CS6.1-54TM-460H460 W≥22.5%−0.30839.314.6970.9 × 44.6 in9
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Bluesun BSM460M-72HBD?

Calculated from the panel area (2.17 m²): about 21.2% for the 460 W class. 460 W over 2.17 m² equals about 212 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 771 kWh per year per 460 W panel in Los Angeles and about 844 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.377 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 54.3 V, Vmp at 74 °C cell = 33 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 54.3 V vs max input 60 V; Vmp when hot 33 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

How big and heavy is it?

82.4 × 40.9 × 1.18 in (2,094 × 1,038 × 30 mm), 61.7 lb (28 kg).

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Bluesun — manufacturer datasheet “BSM460M-72HBD BI-FACIAL MONO PERC 440 W- 460 W LEADING 5%-25% MORE YIELD /”.
  3. Aptos Solar — datasheet Legacy Products.
  4. Canadian Solar — datasheet TOPHiKu6 (All-Black) N-type TOPCon Technology CS6.1-54TM-435|440|445|450|455|460|465H.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Aug 2025). Equipment matched from permit descriptions by model number.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).