144 half-cut cells. Power classes 500–535 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| DF500J-12X12UW | 500 W | 48.70 | 13.32 | 41.30 | 12.07 | ≈18.6% | 468 W | May 21, 2025 |
| DF505J-12X12UW | 505 W | 48.90 | 13.38 | 41.54 | 12.13 | ≈18.8% | 473 W | May 21, 2025 |
| DF510J-12X12UW | 510 W | 49.10 | 13.44 | 41.78 | 12.19 | ≈19.0% | 478 W | May 21, 2025 |
| DF515J-12X12UW | 515 W | 49.30 | 13.50 | 42.02 | 12.25 | ≈19.1% | 482 W | May 21, 2025 |
| DF520J-12X12UW | 520 W | 49.50 | 13.56 | 42.26 | 12.31 | ≈19.3% | 487 W | May 21, 2025 |
| DF525J-12X12UW | 525 W | 49.70 | 13.62 | 42.50 | 12.37 | ≈19.5% | 492 W | May 21, 2025 |
| DF530J-12X12UW | 530 W | 49.86 | 13.68 | 42.74 | 12.43 | ≈19.7% | 497 W | May 21, 2025 |
| DF535J-12X12UW | 535 W | 50.10 | 13.74 | 42.98 | 12.49 | ≈19.9% | 502 W | May 21, 2025 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.348 %/°C |
| Voc coefficient β | −0.258 %/°C |
| Isc coefficient α | +0.026 %/°C |
| Operating cell temperature | NOCT 43.6 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 500 W | 372.3 W | 38.33 V × 9.71 A | 95.8 W | 96% |
| 505 W | 376.4 W | 38.56 V × 9.76 A | 96.8 W | 96% |
| 510 W | 380.4 W | 38.78 V × 9.81 A | 97.9 W | 96% |
| 515 W | 384.5 W | 39 V × 9.86 A | 98.9 W | 96% |
| 520 W | 388.7 W | 39.23 V × 9.91 A | 100 W | 96% |
| 525 W | 392.7 W | 39.45 V × 9.96 A | 101 W | 96% |
| 530 W | 396.7 W | 39.67 V × 10 A | 102.1 W | 96% |
| 535 W | 400.9 W | 39.89 V × 10.05 A | 103.2 W | 96% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 52.2 / 34.3 V | ✗ Not a match: module voltage below MPPT range | 1.36 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 52.2 / 34.3 V | ✓ Within range | 0.66 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 863 | 12,084 | 6.08 |
| Palmdale | 1,835 | 945 | 13,230 | 6.69 |
| Chula Vista | 1,696 | 873 | 12,228 | 6.11 |
| Huntington Beach | 1,643 | 846 | 11,846 | 5.89 |
| Riverside | 1,696 | 873 | 12,228 | 6.21 |
| Santa Clarita | 1,724 | 888 | 12,430 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | Size | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|---|
| Bila Solar DF515J-12X12UW | 515 W | ≈19.1% | −0.348 | 49.3 | 13.5 | — | brand 1× | — |
| SEG Solar SEG-515-BTD-BG | 515 W | ≈26.4% | −0.290 | 40.7 | 16.07 | 67.8 × 44.6 in | product 2023, 2024, 2025, 2026 | 8 |
| Canadian Solar CS6W-520MB-AG | 520 W | ≈20.2% | −0.324 | 48.4 | 13.7 | 89.2 × 44.6 in | product 2024 | 1 |
| LONGi LR5-72HBD-520M | 520 W | ≈20.3% | −0.323 | 48.9 | 13.57 | 88.8 × 44.6 in | product 2026 | 1 |
Calculated from the panel area (2.69 m²): about 19.1% for the 515 W class. 515 W over 2.69 m² equals about 191 W per square meter.
PVWatts v8 with typical-year weather gives about 863 kWh per year per 515 W panel in Los Angeles and about 945 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.348 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.2 V, Vmp at 74 °C cell = 34.3 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.2 V vs max input 60 V; Vmp when hot 34.3 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
This exact series is not in published PVEL Top Performer tables; Bila Solar was named a Top Performer in 1 Scorecard (2026).