Cali-GrafCali-Graf
Solar panelAXITEC

AXITEC AC-330MH/120V

120 half-cut cells. Power classes 305–375 W in the CEC list.

CEC listed · Aug 15, 2019UL 170325-yr product + 25-yr performance warranty
Power class
  • Power (STC)330 Wtolerance +5 / −0 W
  • Efficiency≈19.6%calculated from area
  • %/°C Pmax−0.36CEC test: −0.348
  • Output at year 2585%performance warranty

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 14 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
AC-305MH/120V305 W39.429.8632.379.42≈18.1%283 WAug 15, 2019
AC-310MH/120V310 W39.589.9532.589.51≈18.4%288 WAug 15, 2019
AC-315MH/120V315 W39.7410.0432.799.60≈18.7%293 WAug 15, 2019
AC-320MH/120V320 W39.9210.1333.019.69≈19.0%298 WAug 15, 2019
AC-325MH/120V325 W40.1010.4332.719.93≈19.3%304 WJan 13, 2020
AC-330MH/120V330 W40.2710.5132.9110.02≈19.6%308 WJan 13, 2020
AC-335MH/120V335 W40.4410.6033.1110.11≈19.9%313 WJan 13, 2020
AC-340MH/120V340 W40.6210.6933.3110.21≈20.1%318 WJan 13, 2020
AC-350MH/120V350 W40.1011.1533.6010.42≈20.7%323 WSep 13, 2021
AC-355MH/120V355 W40.3011.2533.8010.51≈21.0%328 WSep 13, 2021
AC-360MH/120V360 W40.5011.3534.0010.59≈21.3%332 WSep 13, 2021
AC-365MH/120V365 W40.7011.4334.2010.68≈21.6%337 WSep 13, 2021
AC-370MH/120V370 W40.9011.5234.4010.76≈21.9%342 WSep 13, 2021
AC-375MH/120V375 W41.1011.6034.6010.84≈22.2%346 WSep 13, 2021
≈ efficiency = Pmax ÷ panel area 1.687 m² (datasheet size).

Build & dimensions

AXITEC datasheet · Cali-Graf calculation

Heat & cold behaviour

AXITEC datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.36 %/°C−0.348 %/°C
Voc coefficient β−0.26 %/°C−0.267 %/°C
Isc coefficient α+0.04 %/°C+0.043 %/°C
Vmp coefficient≈ −0.40 %/°C—
Operating cell temperatureNMOT 45 °CNOCT 44.4 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
305 W221 W30.06 V × 7.35 A56.9 W93%
310 W224.6 W30.26 V × 7.42 A57.8 W93%
315 W228.2 W30.45 V × 7.49 A58.8 W93%
320 W231.9 W30.66 V × 7.56 A59.7 W93%
325 W243 W31.17 V × 7.8 A62.5 W96%
330 W246.7 W31.36 V × 7.87 A63.5 W96%
335 W250.5 W31.55 V × 7.94 A64.5 W96%
340 W254.5 W31.74 V × 8.02 A65.5 W96%
350 W262.7 W31.23 V × 8.41 A67.7 W97%
355 W266.6 W31.41 V × 8.49 A68.7 W97%
360 W270.2 W31.6 V × 8.55 A69.7 W97%
365 W274.1 W31.78 V × 8.62 A70.7 W97%
370 W277.7 W31.97 V × 8.69 A71.6 W97%
375 W281.4 W32.16 V × 8.75 A72.6 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

AXITEC datasheet
Packaging: 31 per pallet

Certifications

CEC PV Module List (Oct 7, 2026) · AXITEC datasheet
UL 1703IEC 61730Fire rating Type 1 (UL 61730)

Warranty & degradation

AXITEC datasheet

Inverter compatibility & string sizing

AXITEC datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
42.7 V
Voc when cold
per panel
26.4 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V42.7 / 26.4 V⚠ Works; below MPPT at peak heat1.14
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V42.7 / 26.4 V✗ Not a match: module voltage below MPPT range0.87
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V42.7 / 26.4 V⚠ Works; below MPPT at peak heat0.42
Enphase IQ8M-72-2-US260–460 W60 V30–45 V42.7 / 26.4 V⚠ Works; below MPPT at peak heat1.02
Enphase IQ8A-72-2-US295–500 W60 V32–45 V42.7 / 26.4 V⚠ Works; below MPPT at peak heat0.95
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67655311,6156.08
Palmdale1,83560612,7176.69
Chula Vista1,69656011,7536.11
Huntington Beach1,64354211,3865.89
Riverside1,69656011,7536.21
Santa Clarita1,72456911,9476.28
758Jan759Feb974Mar1,076Apr1,062May1,129Jun1,189Jul1,203Aug1,052Sep928Oct798Nov690DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 330 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizeWarrantyPVEL (product / brand)SoCal permits (series)
AXITEC AC-330MH/120V330 W≈19.6%−0.34840.2710.5166.3 × 39.4 in25 / 25 yr——
LONGi LR4-60HPB-335M335 W≈18.5%−0.33739.910.76——product 2021, 2022193
JinkoSolar JKM330M-60HBL330 W≈19.6%−0.40640.610.6166.3 × 39.4 in10 / 25 yrbrand 12× (2014–2026)45
Qcells Q.PEAK DUO-G8+ 330330 W≈18.4%−0.34339.7110.5268.5 × 40.6 in25 / 25 yrproduct 202220
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the AXITEC AC-330MH/120V?

Calculated from the panel area (1.69 m²): about 19.6% for the 330 W class. 330 W over 1.69 m² equals about 196 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 553 kWh per year per 330 W panel in Los Angeles and about 606 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.36 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 42.7 V, Vmp at 74 °C cell = 26.4 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

25 years on the product and 25 years on performance: at least 85% after 25 years (manufacturer datasheet).

How big and heavy is it?

66.3 × 39.4 × 1.38 in (1,684 × 1,002 × 35 mm), 45.6 lb (20.7 kg).

What fire rating does it have?

UL 61730 fire rating Type 1 per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. AXITEC — manufacturer datasheet “320–330 Wp AXIblackpremium X HC High performance solar module”.
  3. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  4. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  5. Qcells — manufacturer datasheet “Q.PEAK DUO-G8+ 345-360 EN ENDURING HIGH”.
  6. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).