Solar panelAuxin Solar

Auxin Solar AXN10M435W

108 cells. Power classes 415–620 W in the CEC list.

CEC listed · May 22, 2023UL 61730
Power class
  • Power (STC)435 WCEC nameplate
  • Efficiency≈22.4%calculated from area
  • %/°C Pmax−0.340CEC listing test
  • PTC / STC93.3%PTC 406 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 42 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
AXN10M415W415 W38.0413.6932.1812.90≈21.4%387 WNov 1, 2024
AXN10M420W420 W38.2613.7132.6212.89≈21.6%392 WNov 1, 2024
AXN10M425W425 W38.3713.7232.8912.94≈21.9%396 WNov 1, 2024
AXN10M430W430 W38.5813.7433.1312.99≈22.2%401 WNov 1, 2024
AXN10M435W435 W38.6613.7633.4013.02≈22.4%406 WNov 1, 2024
AXN10M440W440 W39.6213.9133.3813.19≈22.7%404 WFeb 23, 2026
AXN10M445W445 W39.6914.0233.4413.31≈22.9%409 WFeb 23, 2026
AXN10M450W450 W39.7514.1433.5113.44≈23.2%414 WFeb 23, 2026
AXN10M455W455 W39.8214.2633.5813.56≈23.5%419 WJun 11, 2025
AXN10M460W460 W39.8814.3833.6413.68≈23.7%423 WJun 11, 2025
AXN10M465W465 W39.9414.4933.7113.81≈24.0%428 WJun 11, 2025
AXN10M470W470 W43.7813.5036.8312.77≈21.9%432 WJun 11, 2025
AXN10M475W475 W43.8513.6136.9012.88≈22.1%437 WJun 11, 2025
AXN10M480W480 W43.9113.7236.9712.99≈22.3%442 WJun 11, 2025
AXN10M485W485 W43.9813.8237.0313.10≈22.6%445 WFeb 23, 2026
AXN10M490W490 W44.0413.9337.1013.22≈22.8%450 WFeb 23, 2026
AXN10M495W495 W44.1014.0437.1713.33≈23.0%454 WFeb 23, 2026
AXN10M500W500 W44.1714.1437.2313.44≈23.3%459 WFeb 23, 2026
AXN10M505W505 W44.2314.2537.3013.55≈23.5%464 WFeb 23, 2026
AXN10M510W510 W44.3014.3537.3613.66≈23.7%469 WFeb 23, 2026
AXN10M515W515 W44.3614.4637.4313.77≈24.0%474 WFeb 23, 2026
AXN10M520W520 W44.4214.5637.4913.88≈24.2%478 WFeb 23, 2026
AXN10M525W525 W44.4914.6737.5613.99≈24.4%483 WFeb 23, 2026
AXN10M530W530 W49.3513.7141.3512.82≈21.1%496 WMay 22, 2023
AXN10M535W535 W49.5013.7841.5012.90≈21.3%500 WMay 22, 2023
AXN10M540W540 W49.6513.8541.6512.97≈21.5%505 WMay 22, 2023
AXN10M545W545 W49.8113.9241.8213.04≈21.7%510 WMay 22, 2023
AXN10M550W550 W52.3513.2444.0112.50≈21.5%505 WJun 11, 2025
AXN10M555W555 W52.4213.3344.0712.59≈21.7%509 WJun 11, 2025
AXN10M560W560 W52.4813.4344.1412.69≈21.9%514 WJun 11, 2025
AXN10M565W565 W52.5513.5244.2112.78≈22.1%519 WJun 11, 2025
AXN10M570W570 W52.6113.6144.2812.88≈22.3%524 WJun 11, 2025
AXN10M575W575 W52.6813.7044.3512.97≈22.5%528 WJun 11, 2025
AXN10M580W580 W52.7513.7944.4113.07≈22.7%533 WJun 11, 2025
AXN10M585W585 W52.8113.8744.4813.16≈22.9%539 WMar 2, 2026
AXN10M590W590 W52.8713.9744.5513.25≈23.0%544 WMar 2, 2026
AXN10M595W595 W52.9414.0544.6113.34≈23.2%549 WMar 2, 2026
AXN10M600W600 W53.0014.1444.6813.44≈23.4%554 WMar 2, 2026
AXN10M605W605 W53.0614.2344.7413.53≈23.6%558 WMar 2, 2026
AXN10M610W610 W53.1314.3144.8113.62≈23.8%563 WMar 2, 2026
AXN10M615W615 W53.1914.4044.8713.71≈24.0%568 WMar 2, 2026
AXN10M620W620 W53.2514.4944.9413.80≈24.2%573 WMar 2, 2026
≈ efficiency = Pmax ÷ CEC-listed area 1.94 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.340 %/°C
Voc coefficient β−0.266 %/°C
Isc coefficient α+0.062 %/°C
Operating cell temperatureNOCT 46.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
415 W284.2 W27.96 V × 10.17 A72.4 W87%
420 W287.9 W28.34 V × 10.16 A73.4 W87%
425 W291.4 W28.58 V × 10.2 A74.3 W87%
430 W294.7 W28.79 V × 10.24 A75.1 W87%
435 W297.7 W29.02 V × 10.26 A75.9 W87%
440 W266.9 W26.47 V × 10.09 A79.9 W91%
445 W270 W26.52 V × 10.18 A80.8 W91%
450 W273 W26.57 V × 10.27 A81.7 W91%
455 W276.1 W26.63 V × 10.37 A82.6 W91%
460 W279.1 W26.68 V × 10.46 A83.5 W91%
465 W282.1 W26.73 V × 10.56 A84.4 W91%
470 W329.4 W31.8 V × 10.36 A84.2 W90%
475 W332.9 W31.86 V × 10.45 A85.1 W90%
480 W336.4 W31.92 V × 10.54 A86 W90%
485 W306.6 W30.5 V × 10.05 A88.6 W91%
490 W309.7 W30.55 V × 10.14 A89.5 W91%
495 W312.9 W30.61 V × 10.22 A90.4 W91%
500 W316.1 W30.66 V × 10.31 A91.3 W91%
505 W319.3 W30.71 V × 10.4 A92.3 W91%
510 W322.4 W30.77 V × 10.48 A93.2 W91%
515 W325.6 W30.82 V × 10.56 A94.1 W91%
520 W328.7 W30.88 V × 10.65 A95 W91%
525 W331.9 W30.93 V × 10.73 A95.9 W91%
530 W388.8 W38.66 V × 10.06 A98.5 W93%
535 W392.7 W38.8 V × 10.12 A99.5 W93%
540 W396.2 W38.94 V × 10.17 A100.4 W93%
545 W400 W39.1 V × 10.23 A101.4 W93%
550 W387.2 W38.16 V × 10.15 A96.6 W88%
555 W390.7 W38.21 V × 10.22 A97.5 W88%
560 W394.3 W38.27 V × 10.3 A98.4 W88%
565 W397.9 W38.33 V × 10.38 A99.3 W88%
570 W401.4 W38.39 V × 10.46 A100.1 W88%
575 W405 W38.45 V × 10.53 A101 W88%
580 W408.6 W38.51 V × 10.61 A101.9 W88%
585 W361.6 W36.02 V × 10.04 A106.1 W91%
590 W364.8 W36.08 V × 10.11 A107 W91%
595 W367.8 W36.13 V × 10.18 A107.9 W91%
600 W370.9 W36.18 V × 10.25 A108.8 W91%
605 W374 W36.24 V × 10.32 A109.7 W91%
610 W377 W36.29 V × 10.39 A110.6 W91%
615 W380.1 W36.34 V × 10.46 A111.5 W91%
620 W383.2 W36.4 V × 10.53 A112.5 W91%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

RETC PV Module Index
3
RETC PV Module Index
Auxin Solar recognized 2023–2026
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Auxin Solar

YearRecognition
2023High Achievement in Performance (Module efficiency, Ptc-to-stc ratio)
2024Test Category High Achiever
2026Performance discipline high achiever (Iam, Lid, Temperature coefficient); Quality discipline high achiever (BOM verification); Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
41 V
Voc when cold
per panel
26.8 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V41 / 26.8 V⚠ Works; below MPPT at peak heat1.5
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V41 / 26.8 V✗ Not a match: module voltage below MPPT range1.14
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V41 / 26.8 V⚠ Works; below MPPT at peak heat0.56
Enphase IQ8M-72-2-US260–460 W60 V30–45 V41 / 26.8 V⚠ Works; below MPPT at peak heat1.34
Enphase IQ8A-72-2-US295–500 W60 V32–45 V41 / 26.8 V⚠ Works; below MPPT at peak heat1.25
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67672911,6656.08
Palmdale1,83579812,7726.69
Chula Vista1,69673811,8046.11
Huntington Beach1,64371511,4355.89
Riverside1,69673811,8046.21
Santa Clarita1,72475011,9996.28
761Jan762Feb978Mar1,080Apr1,067May1,134Jun1,194Jul1,208Aug1,057Sep932Oct801Nov693DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 435 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
Auxin Solar AXN10M435W435 W≈22.4%−0.34038.6613.76———
Canadian Solar CS3N-430MS430 W≈21.8%−0.33245.711.8625 yrproduct 202346
Qcells Q.TRON BLK M-G2+ 435435 W≥22.3%−0.27639.613.8225 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-435QD435 W≈22.3%−0.29438.9414.0525 / 30 yrbrand 7× (2017–2025)39
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Auxin Solar AXN10M435W?

Calculated from the panel area (2.15 m²): about 22.4% for the 435 W class. 435 W over 2.15 m² equals about 202 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 729 kWh per year per 435 W panel in Los Angeles and about 798 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.340 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 41 V, Vmp at 74 °C cell = 26.8 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  3. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  4. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. RETC — PV Module Index reports 2023–2026.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).