This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.
RETC PV Module Index — Aptos Solar
Year
Recognition
2023
High Achievement in Performance (LeTID RESISTANCE)
2024
Test Category High Achiever
Inverter compatibility & string sizing
Aptos Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
55.9 V
Voc when cold
per panel
37.3 V
Vmp when hot
per panel
10
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
2–10
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
3–10
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
3–10
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
7–8
Microinverters (one per panel)
No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
997
11,967
6.08
Palmdale
1,835
1,092
13,102
6.69
Chula Vista
1,696
1,009
12,109
6.11
Huntington Beach
1,643
978
11,731
5.89
Riverside
1,696
1,009
12,109
6.21
Santa Clarita
1,724
1,026
12,309
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Compare with similar 595 W panels
CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits
Panel
Pmax
Efficiency
γ Pmax (CEC)
Voc, V
Isc, A
PVEL (product / brand)
SoCal permits (series)
Aptos Solar DNA-144-BFN10-595W-DG
595 W
≥23%
−0.301
52.5
13.95
—
—
Phono Solar PS595M8GFH-24/TNH
595 W
≈23.2%
−0.293
53.2
13.84
product 2024, 2025
1
Qcells Q.PEAK DUO XL-G11S.3/BFG 595
595 W
≈21.9%
−0.348
53.63
13.77
product 2024, 2025, 2026
1
VSUN (Vietnam Sunergy) VSUN595N-144MH
595 W
≈23.1%
−0.309
52.69
13.98
brand 6× (2021–2026)
1
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.
How efficient is the Aptos Solar DNA-144-BFN10-595W-DG?
The Aptos Solar datasheet guarantees at least 23% module efficiency for the 595 W class (up to 23.2% for 600 W). 595 W over 2.58 m² equals about 230 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 997 kWh per year per 595 W panel in Los Angeles and about 1,092 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.29 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 55.9 V, Vmp at 74 °C cell = 37.3 V). Final design must follow the inverter manual and NEC 690.7.
Aptos Solar — document library on the manufacturer’s website (links above).
Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
RETC — PV Module Index reports 2023–2024.
NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
Building permits — Southern California permit portals. Equipment matched from permit descriptions.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.