Cali-GrafCali-Graf
Solar panelAptos Solar

Aptos Solar DNA-120-MF23 330

120 half-cut cells. Power classes 320–340 W in the CEC list.

CEC listed · Dec 23, 2019UL 1703
Power class
  • Power (STC)330 WCEC nameplate
  • Efficiency≈19.6%calculated from area
  • %/°C Pmax−0.40CEC test: −0.403
  • Degradation / yr0.54%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
DNA-120-MF23-320W {Blk}320 W39.9210.1333.019.69≈19.0%290 WJan 21, 2020
DNA-120-MF23-320W {Wht}320 W39.9210.1333.019.69≈19.0%299 WDec 23, 2019
DNA-120-MF23-325W {Blk}325 W40.1010.4332.719.93≈19.3%295 WJan 21, 2020
DNA-120-MF23-325W {Wht}325 W40.1010.4332.719.93≈19.3%304 WDec 23, 2019
DNA-120-MF23-330W {Blk}330 W40.2710.5132.9110.02≈19.6%300 WJan 21, 2020
DNA-120-MF23-330W {Wht}330 W40.2710.5132.9110.02≈19.6%309 WDec 23, 2019
DNA-120-MF23-335W {Blk}335 W40.4410.6033.1110.11≈19.9%304 WJan 21, 2020
DNA-120-MF23-335W {Wht}335 W40.4410.6033.1110.11≈19.9%313 WDec 23, 2019
DNA-120-MF23-340W {Blk}340 W40.6210.6933.3110.21≈20.1%309 WJan 21, 2020
DNA-120-MF23-340W {Wht}340 W40.6210.6933.3110.21≈20.1%318 WDec 23, 2019
≈ efficiency = Pmax ÷ panel area 1.687 m² (datasheet size).

Build & dimensions

Aptos Solar datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

Aptos Solar datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.40 %/°C−0.403 %/°C
Voc coefficient β−0.31 %/°C−0.316 %/°C
Isc coefficient α—+0.069 %/°C
Vmp coefficient≈ −0.47 %/°C—
Operating cell temperatureNMOT 45 °CNOCT 48.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
320 W220.3 W30.22 V × 7.29 A——
320 W239.3 W31.45 V × 7.61 A61.6 W96%
325 W223.7 W29.95 V × 7.47 A——
325 W243 W31.17 V × 7.8 A62.5 W96%
330 W227.1 W30.13 V × 7.54 A——
330 W246.7 W31.36 V × 7.87 A63.5 W96%
335 W230.6 W30.32 V × 7.61 A——
335 W250.5 W31.55 V × 7.94 A64.5 W96%
340 W234.3 W30.5 V × 7.68 A——
340 W254.5 W31.74 V × 8.02 A65.5 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Aptos Solar datasheet
Packaging: 30 per pallet

Certifications

CEC PV Module List (Oct 7, 2026) · Aptos Solar datasheet
UL 1703Fire rating Class C (UL 61730)

Warranty & degradation

Aptos Solar datasheet

Independent reliability testing

RETC PV Module Index
2
RETC PV Module Index
Aptos Solar recognized 2023–2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Aptos Solar

YearRecognition
2023High Achievement in Performance (LeTID RESISTANCE)
2024Test Category High Achiever

Inverter compatibility & string sizing

Aptos Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.1 V
Voc when cold
per panel
25.3 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.1 / 25.3 V⚠ Works; below MPPT at peak heat1.14
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.1 / 25.3 V✗ Not a match: module voltage below MPPT range0.87
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.1 / 25.3 V⚠ Works; below MPPT at peak heat0.42
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.1 / 25.3 V⚠ Works; below MPPT at peak heat1.02
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.1 / 25.3 V⚠ Works; below MPPT at peak heat0.95
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67655311,6156.08
Palmdale1,83560612,7176.69
Chula Vista1,69656011,7536.11
Huntington Beach1,64354211,3865.89
Riverside1,69656011,7536.21
Santa Clarita1,72456911,9476.28
758Jan759Feb974Mar1,076Apr1,062May1,129Jun1,189Jul1,203Aug1,052Sep928Oct798Nov690DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 330 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizePVEL (product / brand)SoCal permits (series)
Aptos Solar DNA-120-MF23 330330 W≈19.6%−0.40340.2710.5166.3 × 39.4 in——
LONGi LR4-60HPB-335M335 W≈18.5%−0.33739.910.76—product 2021, 2022193
JinkoSolar JKM330M-60HBL330 W≈19.6%−0.40640.610.6166.3 × 39.4 inbrand 12× (2014–2026)45
Qcells Q.PEAK DUO-G8+ 330330 W≈18.4%−0.34339.7110.5268.5 × 40.6 inproduct 202220
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About Aptos Solar

CEC PV Module List (Oct 7, 2026) · RETC PV Module Index · building permits

Other series by SoCal permits

DNA-144-MF26 · 23DNA-120-MF10 · 22DNA-120-MF26 · 8DNA-120-BF10 · 2DNA-108-BF10 · 1DNA-108-MF10 · 1

Questions & answers

How efficient is the Aptos Solar DNA-120-MF23 330?

Calculated from the panel area (1.69 m²): about 19.6% for the 330 W class. 330 W over 1.69 m² equals about 196 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 553 kWh per year per 330 W panel in Los Angeles and about 606 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.40 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.1 V, Vmp at 74 °C cell = 25.3 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

25 years on the product (manufacturer datasheet).

How big and heavy is it?

66.3 × 39.4 × 1.38 in (1,684 × 1,002 × 35 mm), 41.9 lb (19 kg).

What fire rating does it have?

UL 61730 fire rating Class C per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Aptos Solar — datasheet Legacy Products.
  3. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  4. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  5. Qcells — manufacturer datasheet “Q.PEAK DUO-G8+ 345-360 EN ENDURING HIGH”.
  6. Aptos Solar — document library on the manufacturer’s website (links above).
  7. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  8. RETC — PV Module Index reports 2023–2024.
  9. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  10. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  11. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  12. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  13. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).