Cali-GrafCali-Graf
Solar panelAptos Solar

Aptos Solar DNA-120-BFN10-475W-DG

120 half-cut cells. Power classes 470–485 W in the CEC list.

CEC listed · Jun 21, 2024UL 61730
Power class
  • Power (STC)475 WCEC nameplate
  • Efficiency≈22.0%calculated from area
  • %/°C Pmax−0.298CEC listing test
  • PTC / STC94.9%PTC 451 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 4 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
DNA-120-BFN10-470W-DG470 W42.3814.1535.0513.41≈21.8%446 WJun 21, 2024
DNA-120-BFN10-475W-DG475 W42.4914.2335.2113.49≈22.0%451 WJun 21, 2024
DNA-120-BFN10-480W-DG480 W42.6114.3135.3813.57≈22.2%456 WJun 21, 2024
DNA-120-BFN10-485W-DG485 W42.7214.4135.5513.64≈22.5%460 WJun 21, 2024
≈ efficiency = Pmax ÷ CEC-listed area 2.16 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.298 %/°C
Voc coefficient β−0.240 %/°C
Isc coefficient α+0.041 %/°C
Operating cell temperatureNOCT 43.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
470 W353.2 W34.09 V × 10.36 A89.7 W95%
475 W356.9 W34.25 V × 10.42 A90.6 W95%
480 W360.7 W34.41 V × 10.48 A91.6 W95%
485 W364.3 W34.58 V × 10.54 A92.5 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

RETC PV Module Index
2
RETC PV Module Index
Aptos Solar recognized 2023–2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Aptos Solar

YearRecognition
2023High Achievement in Performance (LeTID RESISTANCE)
2024Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44.8 V
Voc when cold
per panel
29.3 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V44.8 / 29.3 V✗ Not a match: module voltage below MPPT range1.25
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V44.8 / 29.3 V✓ Within range0.61
Enphase IQ8A-72-2-US295–500 W60 V32–45 V44.8 / 29.3 V⚠ Works; below MPPT at peak heat1.36
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67679611,9426.08
Palmdale1,83587213,0746.69
Chula Vista1,69680612,0846.11
Huntington Beach1,64378011,7065.89
Riverside1,69680612,0846.21
Santa Clarita1,72481912,2846.28
779Jan780Feb1,001Mar1,106Apr1,092May1,161Jun1,223Jul1,237Aug1,082Sep954Oct820Nov710DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 475 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Aptos Solar DNA-120-BFN10-475W-DG475 W≈22%−0.29842.4914.23——
REC Group REC475AA Pure-RX475 W≈23.5%−0.24865.79brand 9× (2016–2025)33
SEG Solar SEG-455-BTD-BG455 W≈23.3%−0.26239.7614.11product 2023, 2024, 2025, 20268
Qcells Q.PEAK DUO XL-G10.d 475475 W≥20.5%−0.34053.5811.24product 20236
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Aptos Solar

CEC PV Module List (Oct 7, 2026) · RETC PV Module Index · building permits

Other series by SoCal permits

DNA-144-MF26 · 23DNA-120-MF10 · 22DNA-120-MF26 · 8DNA-120-BF10 · 2DNA-108-BF10 · 1DNA-108-MF10 · 1

Questions & answers

How efficient is the Aptos Solar DNA-120-BFN10-475W-DG?

Calculated from the panel area (2.16 m²): about 22% for the 475 W class. 475 W over 2.16 m² equals about 220 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 796 kWh per year per 475 W panel in Los Angeles and about 872 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.298 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.8 V, Vmp at 74 °C cell = 29.3 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 44.8 V vs max input 60 V; Vmp when hot 29.3 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO XL-G10.d ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. RETC — PV Module Index reports 2023–2024.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).