120 half-cut cells, PERC, bifacial, transparent backsheet. Power classes 435–460 W in the CEC list; datasheet covers 445–460 W.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| DNA-120-BF10-435W | 435 W | 41.02 | 13.66 | 33.76 | 12.91 | ≈20.1% | 403 W | Sep 12, 2022 |
| DNA-120-BF10-440W | 440 W | 41.11 | 13.71 | 33.89 | 13.01 | ≈20.3% | 407 W | Sep 12, 2022 |
| DNA-120-BF10-445W | 445 W | 41.18 | 13.79 | 34.00 | 13.11 | ≥20.6% | 412 W | Sep 12, 2022 |
| DNA-120-BF10-450W | 450 W | 41.30 | 13.86 | 34.15 | 13.20 | ≥20.8% | 417 W | Sep 12, 2022 |
| DNA-120-BF10-455W | 455 W | 41.51 | 13.92 | 34.34 | 13.27 | ≥21.0% | 422 W | Sep 12, 2022 |
| DNA-120-BF10-460W | 460 W | 41.50 | 14.01 | 34.20 | 13.45 | ≥21.3% | 434 W | May 21, 2025 |
| Datasheet | CEC listing test | |
|---|---|---|
| Pmax coefficient γ | −0.35 %/°C | −0.337 %/°C |
| Voc coefficient β | −0.27 %/°C | −0.286 %/°C |
| Isc coefficient α | +0.05 %/°C | +0.040 %/°C |
| Vmp coefficient | ≈ −0.40 %/°C | — |
| Operating cell temperature | NMOT 45 °C | NOCT 43.1 °C |
| Class | Pmax, W | Voc, V | Isc, A | Vmp, V | Imp, A |
|---|---|---|---|---|---|
| 445 W | 333.0 | 39.32 | 11.90 | 32.25 | — |
| 450 W | 337.0 | 39.41 | 12.01 | 32.32 | — |
| 455 W | 341.0 | 39.50 | 12.12 | 32.39 | — |
| 460 W | 344.0 | 38.92 | 12.43 | 32.44 | — |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 435 W | 330.7 W | 32.14 V × 10.29 A | 86.2 W | 99% |
| 440 W | 334.5 W | 32.26 V × 10.37 A | 87.2 W | 99% |
| 445 W | 338.2 W | 32.37 V × 10.45 A | 88.1 W | 99% |
| 450 W | 342 W | 32.51 V × 10.52 A | 89.1 W | 99% |
| 455 W | 345.8 W | 32.69 V × 10.58 A | 90.1 W | 99% |
| 460 W | 343.3 W | 32.2 V × 10.66 A | 87.5 W | 95% |
| Year | Recognition |
|---|---|
| 2023 | High Achievement in Performance (LeTID RESISTANCE) |
| 2024 | Test Category High Achiever |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–13 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–13 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–13 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–11 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 44.1 / 27.6 V | ✗ Not a match: module voltage below MPPT range | 1.21 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 44.1 / 27.6 V | ⚠ Works; below MPPT at peak heat | 0.59 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 44.1 / 27.6 V | ⚠ Works; below MPPT at peak heat | 1.42 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 44.1 / 27.6 V | ⚠ Works; below MPPT at peak heat | 1.32 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 771 | 11,564 | 6.08 |
| Palmdale | 1,835 | 844 | 12,662 | 6.69 |
| Chula Vista | 1,696 | 780 | 11,702 | 6.11 |
| Huntington Beach | 1,643 | 756 | 11,337 | 5.89 |
| Riverside | 1,696 | 780 | 11,702 | 6.21 |
| Santa Clarita | 1,724 | 793 | 11,896 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | Size | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|---|
| Aptos Solar DNA-120-BF10 460 | 460 W | ≥21.3% | −0.337 | 41.5 | 14.01 | 75.1 × 44.6 in | — | 2 |
| REC Group REC460AA Pure-RX | 460 W | ≈22.8% | −0.248 | 65.3 | 8.88 | — | brand 9× (2016–2025) | 33 |
| Canadian Solar CS6.1-54TM-460H | 460 W | ≥22.5% | −0.308 | 39.3 | 14.69 | 70.9 × 44.6 in | product 2024, 2025 | 9 |
| SEG Solar SEG-455-BTD-BG | 455 W | ≈23.3% | −0.262 | 39.76 | 14.11 | 67.8 × 44.6 in | product 2023, 2024, 2025, 2026 | 8 |
The Aptos Solar datasheet guarantees at least 21.3% module efficiency for the 460 W class. 460 W over 2.16 m² equals about 213 W per square meter.
PVWatts v8 with typical-year weather gives about 771 kWh per year per 460 W panel in Los Angeles and about 844 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.35 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.1% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.1 V, Vmp at 74 °C cell = 27.6 V). Final design must follow the inverter manual and NEC 690.7.
30 years on the product (manufacturer datasheet).
75.1 × 44.6 × 1.38 in (1,908 × 1,134 × 35 mm), 51 lb (23.1 kg).
Yes. Rear gain depends on mounting height and ground reflectance.
UL 61730 fire rating Type 1 per datasheet.