Cali-GrafCali-Graf
Solar panelAptos Solar

Aptos Solar DNA-120-BF10 460

120 half-cut cells, PERC, bifacial, transparent backsheet. Power classes 435–460 W in the CEC list; datasheet covers 445–460 W.

CEC listed · Sep 12, 2022UL 61730BifacialPERCInstalled in 2 SoCal permits
Power class
  • Power (STC)460 WCEC nameplate
  • Efficiency≥21.3%datasheet minimum
  • %/°C Pmax−0.35CEC test: −0.337
  • PTC / STC94.3%PTC 434 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · Aptos Solar datasheet · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
DNA-120-BF10-435W435 W41.0213.6633.7612.91≈20.1%403 WSep 12, 2022
DNA-120-BF10-440W440 W41.1113.7133.8913.01≈20.3%407 WSep 12, 2022
DNA-120-BF10-445W445 W41.1813.7934.0013.11≥20.6%412 WSep 12, 2022
DNA-120-BF10-450W450 W41.3013.8634.1513.20≥20.8%417 WSep 12, 2022
DNA-120-BF10-455W455 W41.5113.9234.3413.27≥21.0%422 WSep 12, 2022
DNA-120-BF10-460W460 W41.5014.0134.2013.45≥21.3%434 WMay 21, 2025
≈ efficiency = Pmax ÷ panel area 2.164 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

Aptos Solar datasheets · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

Aptos Solar datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.35 %/°C−0.337 %/°C
Voc coefficient β−0.27 %/°C−0.286 %/°C
Isc coefficient α+0.05 %/°C+0.040 %/°C
Vmp coefficient≈ −0.40 %/°C—
Operating cell temperatureNMOT 45 °CNOCT 43.1 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NOCT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
445 W333.039.3211.9032.25—
450 W337.039.4112.0132.32—
455 W341.039.5012.1232.39—
460 W344.038.9212.4332.44—

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
435 W330.7 W32.14 V × 10.29 A86.2 W99%
440 W334.5 W32.26 V × 10.37 A87.2 W99%
445 W338.2 W32.37 V × 10.45 A88.1 W99%
450 W342 W32.51 V × 10.52 A89.1 W99%
455 W345.8 W32.69 V × 10.58 A90.1 W99%
460 W343.3 W32.2 V × 10.66 A87.5 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Aptos Solar datasheet
Packaging: 31 per pallet

Certifications

CEC PV Module List (Oct 7, 2026) · Aptos Solar datasheet
UL 61730UL 1703Fire rating Type 1 (UL 61730)

Warranty & degradation

Aptos Solar datasheet

Independent reliability testing

RETC PV Module Index
2
RETC PV Module Index
Aptos Solar recognized 2023–2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Aptos Solar

YearRecognition
2023High Achievement in Performance (LeTID RESISTANCE)
2024Test Category High Achiever

Inverter compatibility & string sizing

Aptos Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44.1 V
Voc when cold
per panel
27.6 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V44.1 / 27.6 V✗ Not a match: module voltage below MPPT range1.21
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V44.1 / 27.6 V⚠ Works; below MPPT at peak heat0.59
Enphase IQ8M-72-2-US260–460 W60 V30–45 V44.1 / 27.6 V⚠ Works; below MPPT at peak heat1.42
Enphase IQ8A-72-2-US295–500 W60 V32–45 V44.1 / 27.6 V⚠ Works; below MPPT at peak heat1.32
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67677111,5646.08
Palmdale1,83584412,6626.69
Chula Vista1,69678011,7026.11
Huntington Beach1,64375611,3375.89
Riverside1,69678011,7026.21
Santa Clarita1,72479311,8966.28
755Jan756Feb969Mar1,071Apr1,058May1,124Jun1,184Jul1,198Aug1,047Sep924Oct794Nov687DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs DNA-120-BF10 panels in SoCal

building permits · CSLB License Master
2
Permits naming this series
Oct 2025 – Nov 2025
1
Licensed installers
CSLB license on the permit
1
Jurisdictions so far
Palmdale (2)
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Counts grow as more permit portals are loaded.

Compare with similar 460 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizePVEL (product / brand)SoCal permits (series)
Aptos Solar DNA-120-BF10 460460 W≥21.3%−0.33741.514.0175.1 × 44.6 in—2
REC Group REC460AA Pure-RX460 W≈22.8%−0.24865.38.88—brand 9× (2016–2025)33
Canadian Solar CS6.1-54TM-460H460 W≥22.5%−0.30839.314.6970.9 × 44.6 inproduct 2024, 20259
SEG Solar SEG-455-BTD-BG455 W≈23.3%−0.26239.7614.1167.8 × 44.6 inproduct 2023, 2024, 2025, 20268
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About Aptos Solar

CEC PV Module List (Oct 7, 2026) · RETC PV Module Index · building permits

Other series by SoCal permits

DNA-144-MF26 · 23DNA-120-MF10 · 22DNA-120-MF26 · 8DNA-108-BF10 · 1DNA-108-MF10 · 1DNA-144-BF26 · 1

Questions & answers

How efficient is the Aptos Solar DNA-120-BF10 460?

The Aptos Solar datasheet guarantees at least 21.3% module efficiency for the 460 W class. 460 W over 2.16 m² equals about 213 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 771 kWh per year per 460 W panel in Los Angeles and about 844 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.35 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.1 V, Vmp at 74 °C cell = 27.6 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

30 years on the product (manufacturer datasheet).

How big and heavy is it?

75.1 × 44.6 × 1.38 in (1,908 × 1,134 × 35 mm), 51 lb (23.1 kg).

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

What fire rating does it have?

UL 61730 fire rating Type 1 per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Aptos Solar — datasheet DNA-120-BF10-460W445W | 450W | 455W | 460W.
  3. Aptos Solar — datasheet Datasheets – M10.
  4. Canadian Solar — datasheet TOPHiKu6 (All-Black) N-type TOPCon Technology CS6.1-54TM-435|440|445|450|455|460|465H.
  5. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  6. Aptos Solar — document library on the manufacturer’s website (links above).
  7. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  8. RETC — PV Module Index reports 2023–2024.
  9. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  10. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  11. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  12. Building permits — City of Palmdale (Oct 2025 – Nov 2025). Equipment matched from permit descriptions by model number.
  13. Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
  14. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).