Cali-GrafCali-Graf
Solar panelAptos Solar

Aptos Solar DNA-108-BF10 400

108 half-cut cells, PERC, bifacial, transparent backsheet. Power classes 385–415 W in the CEC list; datasheet covers 400–410 W.

CEC listed · Sep 12, 2022UL 61730BifacialPERCSeen in 1 SoCal permit
Power class
  • Power (STC)400 WCEC nameplate
  • Efficiency≥20.5%datasheet minimum
  • %/°C Pmax−0.32CEC test: −0.320
  • PTC / STC93.3%PTC 373 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · Aptos Solar datasheet · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
DNA-108-BF10-385W385 W36.7213.5230.4412.65≈19.7%359 WSep 12, 2022
DNA-108-BF10-390W390 W36.8513.6130.6412.73≈20.0%364 WSep 12, 2022
DNA-108-BF10-395W395 W36.9813.7030.8412.81≈20.2%368 WSep 12, 2022
DNA-108-BF10-400W400 W37.0713.7931.0112.90≥20.5%373 WSep 12, 2022
DNA-108-BF10-405W405 W37.2313.8731.2112.98≥20.7%378 WSep 12, 2022
DNA-108-BF10-410W410 W37.3213.9531.4513.04≥21.0%383 WSep 12, 2022
DNA-108-BF10-415W415 W37.5014.0231.6013.13≈21.3%391 WMay 1, 2025
≈ efficiency = Pmax ÷ panel area 1.953 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

Aptos Solar datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

Aptos Solar datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.32 %/°C−0.320 %/°C
Voc coefficient β−0.25 %/°C−0.248 %/°C
Isc coefficient α+0.04 %/°C+0.036 %/°C
Vmp coefficient≈ −0.36 %/°C—
Operating cell temperatureNMOT 45 °CNOCT 46.9 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
385 W292 W28.2 V × 10.36 A76.2 W99%
390 W295.8 W28.39 V × 10.42 A77.2 W99%
395 W299.6 W28.57 V × 10.49 A78.2 W99%
400 W303.4 W28.73 V × 10.56 A79.2 W99%
405 W307.2 W28.92 V × 10.63 A80.2 W99%
410 W311 W29.14 V × 10.67 A81.2 W99%
415 W307.7 W29.7 V × 10.36 A79.3 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Aptos Solar datasheet
Packaging: 31 per pallet

Certifications

CEC PV Module List (Oct 7, 2026) · Aptos Solar datasheet
UL 61730UL 1703Fire rating Type 1 (UL 61730)

Warranty & degradation

Aptos Solar datasheet

Independent reliability testing

RETC PV Module Index
2
RETC PV Module Index
Aptos Solar recognized 2023–2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Aptos Solar

YearRecognition
2023High Achievement in Performance (LeTID RESISTANCE)
2024Test Category High Achiever

Inverter compatibility & string sizing

Aptos Solar datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
39.2 V
Voc when cold
per panel
25.6 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–15
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–15
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–15
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V39.2 / 25.6 V⚠ Works; below MPPT at peak heat1.38
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V39.2 / 25.6 V✗ Not a match: module voltage below MPPT range1.05
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V39.2 / 25.6 V⚠ Works; below MPPT at peak heat0.51
Enphase IQ8M-72-2-US260–460 W60 V30–45 V39.2 / 25.6 V⚠ Works; below MPPT at peak heat1.23
Enphase IQ8A-72-2-US295–500 W60 V32–45 V39.2 / 25.6 V✗ Not a match: module voltage below MPPT range1.15
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67667012,0676.08
Palmdale1,83573413,2126.69
Chula Vista1,69667812,2116.11
Huntington Beach1,64365711,8305.89
Riverside1,69667812,2116.21
Santa Clarita1,72469012,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 400 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Aptos Solar DNA-108-BF10 400400 W≥20.5%−0.32037.0713.79—1
Qcells Q.PEAK DUO BLK ML-G10+ 400400 W≥20.4%−0.36245.311.14product 2022, 2023221
JA Solar JAM54S31-400/MR400 W≈21.1%−0.32937.0713.79product 2023, 2024152
REC Group REC400AA Pure400 W≈22.3%−0.25648.810.25brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About Aptos Solar

CEC PV Module List (Oct 7, 2026) · RETC PV Module Index · building permits

Other series by SoCal permits

DNA-144-MF26 · 23DNA-120-MF10 · 22DNA-120-MF26 · 8DNA-120-BF10 · 2DNA-108-MF10 · 1DNA-144-BF26 · 1

Questions & answers

How efficient is the Aptos Solar DNA-108-BF10 400?

The Aptos Solar datasheet guarantees at least 20.5% module efficiency for the 400 W class (up to 21% for 410 W). 400 W over 1.95 m² equals about 205 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 670 kWh per year per 400 W panel in Los Angeles and about 734 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.32 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 39.2 V, Vmp at 74 °C cell = 25.6 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

30 years on the product (manufacturer datasheet).

How big and heavy is it?

67.8 × 44.6 × 1.38 in (1,722 × 1,134 × 35 mm), 48.5 lb (22 kg).

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

What fire rating does it have?

UL 61730 fire rating Type 1 per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Aptos Solar — datasheet Legacy Products.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  4. Aptos Solar — document library on the manufacturer’s website (links above).
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. RETC — PV Module Index reports 2023–2024.
  7. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Oct 2023). Equipment matched from permit descriptions by model number.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).