Microinverter. 14 models, 360 W–1.92 kW AC at 208 V / 240 V.
| Model | Nominal AC | Grid voltage | CEC continuous | Rated AC (SAM) | CEC weighted eff. | DC test window | CEC listed | UL 1741 SB |
|---|---|---|---|---|---|---|---|---|
| HYX-M400-S-NA | 360 W | 208 V | 366 W | 366 W | 95.5% | 35–50 V | Jul 11, 2024 | SB |
| HYX-M400-S-NA | 360 W | 240 V | 367 W | 367 W | 95.5% | 35–50 V | Jul 11, 2024 | SB |
| HYX-M500-S-NA | 475 W | 208 V | 478 W | 478 W | 95.5% | 35–50 V | Jul 11, 2024 | SB |
| HYX-M500-S-NA | 475 W | 240 V | 479 W | 479 W | 96.0% | 35–50 V | Jul 11, 2024 | SB |
| HYX-M600-S-NA | 548 W | 208 V | 548 W | 548 W | 96.0% | 35–50 V | May 13, 2024 | SB |
| HYX-M600-S-NA | 548 W | 240 V | 549 W | 549 W | 96.0% | 35–50 V | May 13, 2024 | SB |
| HYX-M800-S-NA | 720 W | 208 V | 721 W | 721 W | 96.0% | 35–50 V | May 13, 2024 | SB |
| HYX-M800-S-NA | 720 W | 240 V | 723 W | 723 W | 96.0% | 35–50 V | May 13, 2024 | SB |
| HYX-M1000-S-NA | 960 W | 208 V | 962 W | 962 W | 96.0% | 35–50 V | May 13, 2024 | SB |
| HYX-M1000-S-NA | 960 W | 240 V | 958 W | 958 W | 96.5% | 35–50 V | May 13, 2024 | SB |
| HYX-M1800-S-NA | 1.66 kW | 208 V | 1.66 kW | 1.66 kW | 96.0% | 35–50 V | Jun 11, 2024 | SB |
| HYX-M1800-S-NA | 1.66 kW | 240 V | 1.66 kW | — | 94.5% | 35–50 V | Jun 11, 2024 | SB |
| HYX-M2000-S-NA | 1.92 kW | 208 V | 1.91 kW | 1.91 kW | 97.0% | 35–50 V | Jun 11, 2024 | SB |
| HYX-M2000-S-NA | 1.92 kW | 240 V | 1.91 kW | 1.91 kW | 96.0% | 35–50 V | Jun 11, 2024 | SB |
| Panel | Power | Voc cold / Vmp hot | Check | DC/AC | Installed together |
|---|---|---|---|---|---|
| Qcells Q.PEAK DUO BLK ML-G10.C+ 410 | 410 W | 48.1 / 30.6 V | ⚠ Below MPPT at peak heat | 0.57 | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 410 | 410 W | 48.1 / 30.6 V | ⚠ Below MPPT at peak heat | 0.57 | — |
| LONGi LR5-54HABB-400M | 400 W | 39.3 / 25.3 V | ⚠ Below MPPT at peak heat | 0.55 | — |
| JA Solar JAM54S31-405/MR | 405 W | 39.4 / 25.5 V | ⚠ Below MPPT at peak heat | 0.56 | — |
| Hyundai Solutions HiN-T440NF(BK) | 440 W | 40.9 / 27 V | ⚠ Below MPPT at peak heat | 0.61 | — |
| Silfab Solar SIL-440QD | 440 W | 41.1 / 28 V | ⚠ Below MPPT at peak heat | 0.61 | — |
| Qcells Q.TRON BLK M-G2+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 0.59 | — |
| Qcells Q.TRON BLK M-G2.H+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 0.59 | — |
| REC Group REC460AA Pure-RX | 460 W | 68.8 / 47.1 V | ✗ Cold Voc above max input | 0.64 | — |
| Elin (Sirius PV) ELNSM54M-HC-410 | 410 W | 39.3 / 25.3 V | ⚠ Below MPPT at peak heat | 0.57 | — |
| Qcells Q.TRON BLK M-G2.C+ 430 | 430 W | 41.3 / 28 V | ⚠ Below MPPT at peak heat | 0.59 | — |
| Tesla TSP-420 | 420 W | 43.4 / 27.7 V | ⚠ Below MPPT at peak heat | 0.58 | — |
| Inverter | Power | CEC weighted eff. | DC test window | UL 1741 SB | Latest CEC | SoCal permits |
|---|---|---|---|---|---|---|
| Zhejiang Hyxi Technology HYX-Mxxx-S-NA | 360 W–1.92 kW | 96.0% | 35–50 V | Yes | 2024 | 0 |
| Enphase Energy IQ8 Series | 240 W–633 W | 97.5% | 25–95 V | 44 of 45 | 2025 | 1,104 |
| Hoymiles HM-xxxNT | 295 W–1.44 kW | 96.5% | 29–48 V | 11 of 12 | 2023 | 3 |
| Power Center Dxxx-M2 | 696 W–696 W | 96.5% | 33–48 V | Yes | 2022 | 2 |
| FOXESS M1-xxxx-NA | 600 W–1.2 kW | 95.5% | 35–50 V | Yes | 2026 | — |
The California Energy Commission lists a weighted efficiency of 94.5–97.0% for Zhejiang Hyxi Technology HYX-Mxxx-S-NA models, measured at six power levels and three DC voltages. The datasheet states a peak efficiency of 96.7%.
The CEC list includes 14 models from 360 W to 1.92 kW AC: HYX-M400-S-NA, HYX-M400-S-NA, HYX-M500-S-NA, HYX-M500-S-NA, HYX-M600-S-NA, HYX-M600-S-NA, HYX-M800-S-NA, HYX-M800-S-NA….
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.
Max DC input voltage is 65 V per the datasheet. CEC tested it at 35–50 V DC.
25 years standard (manufacturer datasheet).