Cali-GrafCali-Graf
MicroinverterZhejiang Hyxi Technology

Zhejiang Hyxi Technology HYX-M800-S-NA

Microinverter. 14 models, 360 W–1.92 kW AC at 208 V / 240 V.

UL 1741 SBCEC listed · May 13, 2024Rapid shutdown
Model
  • Rated AC power720 W
  • CEC weighted efficiency96.0%
  • Max DC input65 V
  • Warranty25 years

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 14 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
HYX-M400-S-NA360 W208 V366 W366 W95.5%35–50 VJul 11, 2024SB
HYX-M400-S-NA360 W240 V367 W367 W95.5%35–50 VJul 11, 2024SB
HYX-M500-S-NA475 W208 V478 W478 W95.5%35–50 VJul 11, 2024SB
HYX-M500-S-NA475 W240 V479 W479 W96.0%35–50 VJul 11, 2024SB
HYX-M600-S-NA548 W208 V548 W548 W96.0%35–50 VMay 13, 2024SB
HYX-M600-S-NA548 W240 V549 W549 W96.0%35–50 VMay 13, 2024SB
HYX-M800-S-NA720 W208 V721 W721 W96.0%35–50 VMay 13, 2024SB
HYX-M800-S-NA720 W240 V723 W723 W96.0%35–50 VMay 13, 2024SB
HYX-M1000-S-NA960 W208 V962 W962 W96.0%35–50 VMay 13, 2024SB
HYX-M1000-S-NA960 W240 V958 W958 W96.5%35–50 VMay 13, 2024SB
HYX-M1800-S-NA1.66 kW208 V1.66 kW1.66 kW96.0%35–50 VJun 11, 2024SB
HYX-M1800-S-NA1.66 kW240 V1.66 kW—94.5%35–50 VJun 11, 2024SB
HYX-M2000-S-NA1.92 kW208 V1.91 kW1.91 kW97.0%35–50 VJun 11, 2024SB
HYX-M2000-S-NA1.92 kW240 V1.91 kW1.91 kW96.0%35–50 VJun 11, 2024SB

DC input (PV side)

Zhejiang Hyxi Technology datasheet · CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

AC output (grid side)

Zhejiang Hyxi Technology datasheet · CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · Zhejiang Hyxi Technology datasheet · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Safety & protection

Zhejiang Hyxi Technology datasheet

Monitoring & communication

Zhejiang Hyxi Technology datasheet

Size, weight & environment

Zhejiang Hyxi Technology datasheet

Warranty

Zhejiang Hyxi Technology datasheet

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
HYX-M800-S-NA: max DC 50 V · MPPT 35–50 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc cold / Vmp hotCheckDC/ACInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 / 30.6 V⚠ Below MPPT at peak heat0.57—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 / 30.6 V⚠ Below MPPT at peak heat0.57—
LONGi LR5-54HABB-400M400 W39.3 / 25.3 V⚠ Below MPPT at peak heat0.55—
JA Solar JAM54S31-405/MR405 W39.4 / 25.5 V⚠ Below MPPT at peak heat0.56—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 / 27 V⚠ Below MPPT at peak heat0.61—
Silfab Solar SIL-440QD440 W41.1 / 28 V⚠ Below MPPT at peak heat0.61—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat0.59—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat0.59—
REC Group REC460AA Pure-RX460 W68.8 / 47.1 V✗ Cold Voc above max input0.64—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 / 25.3 V⚠ Below MPPT at peak heat0.57—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat0.59—
Tesla TSP-420420 W43.4 / 27.7 V⚠ Below MPPT at peak heat0.58—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 720 W inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Zhejiang Hyxi Technology HYX-Mxxx-S-NA360 W–1.92 kW96.0%35–50 VYes20240
Enphase Energy IQ8 Series240 W–633 W97.5%25–95 V44 of 4520251,104
Hoymiles HM-xxxNT295 W–1.44 kW96.5%29–48 V11 of 1220233
Power Center Dxxx-M2696 W–696 W96.5%33–48 VYes20222
FOXESS M1-xxxx-NA600 W–1.2 kW95.5%35–50 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Zhejiang Hyxi Technology

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

HYX-Mxxx-SHYX-Mxxx-SWHYX-Mxxx-SW-NA

Questions & answers

How efficient is the Zhejiang Hyxi Technology HYX-Mxxx-S-NA?

The California Energy Commission lists a weighted efficiency of 94.5–97.0% for Zhejiang Hyxi Technology HYX-Mxxx-S-NA models, measured at six power levels and three DC voltages. The datasheet states a peak efficiency of 96.7%.

What sizes does the Zhejiang Hyxi Technology HYX-Mxxx-S-NA come in?

The CEC list includes 14 models from 360 W to 1.92 kW AC: HYX-M400-S-NA, HYX-M400-S-NA, HYX-M500-S-NA, HYX-M500-S-NA, HYX-M600-S-NA, HYX-M600-S-NA, HYX-M800-S-NA, HYX-M800-S-NA….

Is the Zhejiang Hyxi Technology HYX-Mxxx-S-NA certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the HYX-M800-S-NA’s DC input voltage range?

Max DC input voltage is 65 V per the datasheet. CEC tested it at 35–50 V DC.

What warranty does it have?

25 years standard (manufacturer datasheet).

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. Zhejiang Hyxi Technology — manufacturer datasheet “MICRO INVERTER HYX-M600/800/1000-S/SW-NA”.
  3. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  4. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  5. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  6. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  7. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).