Cali-GrafCali-Graf
MicroinverterSparq Systems

Sparq Systems Q2000-4102

Microinverter. 2 models, 1.2 kW–2 kW AC at 240 V.

CEC listed · Feb 1, 2019
Model
  • Rated AC power2 kW
  • CEC weighted efficiency97.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
Q1200-41021.2 kW240 V1.2 kW1.2 kW96.5%36–38 VFeb 1, 2019—
Q2000-41022 kW240 V1.72 kW1.72 kW97.0%36–38 VMar 13, 2023—

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
Q2000-4102: max DC 38 V · MPPT 36–38 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc cold / Vmp hotCheckDC/ACInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 / 30.6 V✗ Cold Voc above max input0.24—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 / 30.6 V✗ Cold Voc above max input0.24—
LONGi LR5-54HABB-400M400 W39.3 / 25.3 V✗ Cold Voc above max input0.23—
JA Solar JAM54S31-405/MR405 W39.4 / 25.5 V✗ Cold Voc above max input0.24—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 / 27 V✗ Cold Voc above max input0.26—
Silfab Solar SIL-440QD440 W41.1 / 28 V✗ Cold Voc above max input0.26—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 / 28 V✗ Cold Voc above max input0.25—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 / 28 V✗ Cold Voc above max input0.25—
REC Group REC460AA Pure-RX460 W68.8 / 47.1 V✗ Cold Voc above max input0.27—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 / 25.3 V✗ Cold Voc above max input0.24—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 / 28 V✗ Cold Voc above max input0.25—
Tesla TSP-420420 W43.4 / 27.7 V✗ Cold Voc above max input0.24—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 2 kW inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Sparq Systems Qxxxx-41021.2 kW–2 kW97.0%36–38 V—20230
APsystems (Altenergy Power System) QSxxxx1.2 kW–1.92 kW96.5%27–48 V2 of 32025—
Sol-Ark SA-MP-1000-208/240V1 kW–1,000 kW96.0%40–55 VYes2025—
Northern Electric & Power BDM-xxx-240A300 W–2 kW96.5%22–55 VYes2024—
Zhejiang Hyxi Technology HYX-Mxxx-S-NA360 W–1.92 kW97.0%35–50 VYes2024—
Same type and grid voltage, power range covering this model; same fields from the same sources.

Questions & answers

How efficient is the Sparq Systems Qxxxx-4102?

The California Energy Commission lists a weighted efficiency of 96.5–97.0% for Sparq Systems Qxxxx-4102 models, measured at six power levels and three DC voltages.

What sizes does the Sparq Systems Qxxxx-4102 come in?

The CEC list includes 2 models from 1.2 kW to 2 kW AC: Q1200-4102, Q2000-4102.

Is the Sparq Systems Qxxxx-4102 certified to UL 1741 SB?

The CEC list does not show UL 1741 SB certification for these models.

What is the Q2000-4102’s DC input voltage range?

CEC tested it at 36–38 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).