Cali-GrafCali-Graf
MicroinverterSolaX Power

SolaX Power A1-Micro 450P

Microinverter. 5 models, 300 W–600 W AC at 240 V.

UL 1741 SBCEC listed · Oct 11, 2024
Model
  • Rated AC power450 W
  • CEC weighted efficiency93.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 5 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
A1-Micro 300P300 W240 V320 W320 W93.0%28–45 VOct 11, 2024SB
A1-Micro 400P400 W240 V410 W410 W94.0%29–45 VOct 11, 2024SB
A1-Micro 450P450 W240 V458 W458 W93.5%30–45 VOct 11, 2024SB
A1-Micro 500P500 W240 V506 W506 W94.0%30–45 VOct 11, 2024SB
A1-Micro 600P600 W240 V594 W594 W94.0%32–45 VOct 11, 2024SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
A1-Micro 450P: max DC 45 V · MPPT 30–45 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc cold / Vmp hotCheckDC/ACInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 / 30.6 V✗ Cold Voc above max input0.9—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 / 30.6 V✗ Cold Voc above max input0.9—
LONGi LR5-54HABB-400M400 W39.3 / 25.3 V⚠ Below MPPT at peak heat0.87—
JA Solar JAM54S31-405/MR405 W39.4 / 25.5 V⚠ Below MPPT at peak heat0.88—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 / 27 V⚠ Below MPPT at peak heat0.96—
Silfab Solar SIL-440QD440 W41.1 / 28 V⚠ Below MPPT at peak heat0.96—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat0.94—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat0.94—
REC Group REC460AA Pure-RX460 W68.8 / 47.1 V✗ Cold Voc above max input1—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 / 25.3 V⚠ Below MPPT at peak heat0.9—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat0.94—
Tesla TSP-420420 W43.4 / 27.7 V⚠ Below MPPT at peak heat0.92—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 450 W inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
SolaX Power A1-Micro xxxP300 W–600 W93.5%30–45 VYes20240
Enphase Energy IQ8 Series240 W–633 W97.5%25–95 V44 of 4520251,104
Enphase Energy IQ7 Series190 W–384 W97.5%22–64 V114 of 1192022471
Hoymiles HM-xxxNT295 W–1.44 kW96.5%29–48 V11 of 1220233
Enphase Energy IQ9 Series405 W–440 W97.5%28–45 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About SolaX Power

CEC Grid Support Inverter List (Oct 7, 2026)

Questions & answers

How efficient is the SolaX Power A1-Micro xxxP?

The California Energy Commission lists a weighted efficiency of 93.0–94.0% for SolaX Power A1-Micro xxxP models, measured at six power levels and three DC voltages.

What sizes does the SolaX Power A1-Micro xxxP come in?

The CEC list includes 5 models from 300 W to 600 W AC: A1-Micro 300P, A1-Micro 400P, A1-Micro 450P, A1-Micro 500P, A1-Micro 600P.

Is the SolaX Power A1-Micro xxxP certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the A1-Micro 450P’s DC input voltage range?

CEC tested it at 30–45 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).