Cali-GrafCali-Graf
MicroinverterSigenergy

Sigenergy SigenMicro 768 US

Microinverter. 4 models, 380 W–960 W AC at 240 V.

UL 1741 SBCEC listed · Oct 13, 2025
Model
  • Rated AC power770 W
  • CEC weighted efficiency97.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 4 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
SigenMicro 384 US380 W240 V388 W388 W97.0%35–55 VOct 13, 2025SB
SigenMicro 480 US480 W240 V484 W484 W97.0%35–55 VOct 13, 2025SB
SigenMicro 768 US770 W240 V776 W776 W97.0%35–55 VOct 13, 2025SB
SigenMicro 960 US960 W240 V969 W969 W97.0%35–55 VOct 13, 2025SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
SigenMicro 768 US: max DC 55 V · MPPT 35–55 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc cold / Vmp hotCheckDC/ACInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 / 30.6 V⚠ Below MPPT at peak heat0.53—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 / 30.6 V⚠ Below MPPT at peak heat0.53—
LONGi LR5-54HABB-400M400 W39.3 / 25.3 V⚠ Below MPPT at peak heat0.52—
JA Solar JAM54S31-405/MR405 W39.4 / 25.5 V⚠ Below MPPT at peak heat0.52—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 / 27 V⚠ Below MPPT at peak heat0.57—
Silfab Solar SIL-440QD440 W41.1 / 28 V⚠ Below MPPT at peak heat0.57—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat0.55—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat0.55—
REC Group REC460AA Pure-RX460 W68.8 / 47.1 V✗ Cold Voc above max input0.59—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 / 25.3 V⚠ Below MPPT at peak heat0.53—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 / 28 V⚠ Below MPPT at peak heat0.55—
Tesla TSP-420420 W43.4 / 27.7 V⚠ Below MPPT at peak heat0.54—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 770 W inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Sigenergy SigenMicro xxx US380 W–960 W97.0%35–55 VYes20250
Enphase Energy IQ8 Series240 W–633 W97.5%25–95 V44 of 4520251,104
Hoymiles HM-xxxNT295 W–1.44 kW96.5%29–48 V11 of 1220233
Power Center Dxxx-M2696 W–696 W96.5%33–48 VYes20222
FOXESS M1-1000-NA1 kW–1 kW95.5%35–50 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

Questions & answers

How efficient is the Sigenergy SigenMicro xxx US?

The California Energy Commission lists a weighted efficiency of 97.0% for Sigenergy SigenMicro xxx US models, measured at six power levels and three DC voltages.

What sizes does the Sigenergy SigenMicro xxx US come in?

The CEC list includes 4 models from 380 W to 960 W AC: SigenMicro 384 US, SigenMicro 480 US, SigenMicro 768 US, SigenMicro 960 US.

Is the Sigenergy SigenMicro xxx US certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the SigenMicro 768 US’s DC input voltage range?

CEC tested it at 35–55 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).