MicroinverterQcells

Qcells Q.MICRO.380C-G2

Microinverter. 2 models, 330 W–380 W AC at 208 V / 240 V.

UL 1741 SBCEC listed · Jun 22, 2026
Model
  • Rated AC power380 W
  • CEC weighted efficiency97.0%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
Q.MICRO.380C-G2330 W208 V330 W330 W97.0%30–41 VJun 22, 2026SB
Q.MICRO.380C-G2380 W240 V379 W379 W97.0%30–40 VJun 22, 2026SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Monitoring & communication

CEC Grid Support Inverter List (Oct 7, 2026)

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
Q.MICRO.380C-G2: max DC 40 V · MPPT 30–40 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc cold / Vmp hotCheckDC/ACInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 / 30.6 V✗ Cold Voc above max input1.08—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 / 30.6 V✗ Cold Voc above max input1.08—
LONGi LR5-54HABB-400M400 W39.3 / 25.3 V⚠ Below MPPT at peak heat1.06—
JA Solar JAM54S31-405/MR405 W39.4 / 25.5 V⚠ Below MPPT at peak heat1.07—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 / 27 V✗ Cold Voc above max input1.16—
Silfab Solar SIL-440QD440 W41.1 / 28 V✗ Cold Voc above max input1.16—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 / 28 V✗ Cold Voc above max input1.13—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 / 28 V✗ Cold Voc above max input1.13—
REC Group REC460AA Pure-RX460 W68.8 / 47.1 V✗ Cold Voc above max input1.21—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 / 25.3 V⚠ Below MPPT at peak heat1.08—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 / 28 V✗ Cold Voc above max input1.13—
Tesla TSP-420420 W43.4 / 27.7 V✗ Cold Voc above max input1.11—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 380 W inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Qcells Q.MICRO.380C-G2330 W–380 W97.0%30–40 VYes20260
Enphase Energy IQ8 Series240 W–633 W97.5%25–95 V44 of 4520251,104
Enphase Energy IQ7 Series190 W–384 W97.5%22–64 V114 of 1192022471
Hoymiles HM-xxxNT295 W–1.44 kW96.5%29–48 V11 of 1220233
Enphase Energy IQ9 Series405 W–440 W97.5%28–45 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Qcells

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

Q.MI.380C-G2Q.MI.xxxB-P2Q.MICRO.xxxB-P2

Questions & answers

How efficient is the Qcells Q.MICRO.380C-G2?

The California Energy Commission lists a weighted efficiency of 97.0% for Qcells Q.MICRO.380C-G2 models, measured at six power levels and three DC voltages.

What sizes does the Qcells Q.MICRO.380C-G2 come in?

The CEC list includes 2 models from 330 W to 380 W AC: Q.MICRO.380C-G2, Q.MICRO.380C-G2.

Is the Qcells Q.MICRO.380C-G2 certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the Q.MICRO.380C-G2’s DC input voltage range?

CEC tested it at 30–40 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).