Cali-GrafCali-Graf
MicroinverterPower Center

Power Center D800-M2A-240A

Microinverter. 2 models, 600 W–768 W AC at 240 V.

UL 1741 SBCEC listed · Feb 3, 2025
Model
  • Rated AC power768 W
  • CEC weighted efficiency96.5%

Models & power ratings

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library · 2 models
ModelNominal ACGrid voltageCEC continuousRated AC (SAM)CEC weighted eff.DC test windowCEC listedUL 1741 SB
D600-M2A-240A600 W240 V576 W576 W96.5%22–55 VFeb 3, 2025SB
D800-M2A-240A768 W240 V772 W772 W96.5%22–55 VFeb 3, 2025SB

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
D800-M2A-240A: max DC 55 V · MPPT 22–55 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc cold / Vmp hotCheckDC/ACInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 / 30.6 V✓ Within range0.53—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 / 30.6 V✓ Within range0.53—
LONGi LR5-54HABB-400M400 W39.3 / 25.3 V✓ Within range0.52—
JA Solar JAM54S31-405/MR405 W39.4 / 25.5 V✓ Within range0.52—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 / 27 V✓ Within range0.57—
Silfab Solar SIL-440QD440 W41.1 / 28 V✓ Within range0.57—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 / 28 V✓ Within range0.56—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 / 28 V✓ Within range0.56—
REC Group REC460AA Pure-RX460 W68.8 / 47.1 V✗ Cold Voc above max input0.6—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 / 25.3 V✓ Within range0.53—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 / 28 V✓ Within range0.56—
Tesla TSP-420420 W43.4 / 27.7 V✓ Within range0.54—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

Compare with similar 768 W inverters

CEC Grid Support Inverter List (Oct 7, 2026) · building permits
InverterPowerCEC weighted eff.DC test windowUL 1741 SBLatest CECSoCal permits
Power Center Dxxx-M2A-240A600 W–768 W96.5%22–55 VYes20250
Enphase Energy IQ8 Series240 W–633 W97.5%25–95 V44 of 4520251,104
Hoymiles HM-xxxNT295 W–1.44 kW96.5%29–48 V11 of 1220233
Power Center Dxxx-M2696 W–696 W96.5%33–48 VYes20222
FOXESS M1-1000-NA1 kW–1 kW95.5%35–50 VYes2026—
Same type and grid voltage, power range covering this model; same fields from the same sources.

About Power Center

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

Dxxx-M2 · 2 permitsDxxx-M1A-208ADxxx-M1A-240ADxxx-M2A-208ADxxx-M1Dxxxx-M4

Questions & answers

How efficient is the Power Center Dxxx-M2A-240A?

The California Energy Commission lists a weighted efficiency of 96.5% for Power Center Dxxx-M2A-240A models, measured at six power levels and three DC voltages.

What sizes does the Power Center Dxxx-M2A-240A come in?

The CEC list includes 2 models from 600 W to 768 W AC: D600-M2A-240A, D800-M2A-240A.

Is the Power Center Dxxx-M2A-240A certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the D800-M2A-240A’s DC input voltage range?

CEC tested it at 22–55 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  6. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).