Cali-GrafCali-Graf
MicroinverterNorthern Electric & Power

Northern Electric & Power BDM-800-277A

Microinverter. 1 model, 800 W AC at 277 V.

UL 1741 SBCEC listed · May 1, 2025
  • Rated AC power800 W
  • CEC weighted efficiency96.5%

DC input (PV side)

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library

AC output (grid side)

CEC Grid Support Inverter List (Oct 7, 2026)

Efficiency

CEC Grid Support Inverter List (Oct 7, 2026) · NLR SAM inverter library
CEC weighted efficiency is measured by an accredited lab at six power levels and three DC voltages — the number to compare between inverters.

Grid & smart-inverter certification

CEC Grid Support Inverter List (Oct 7, 2026)
UL 1741 SB is required for new interconnections in California (Rule 21) since 2026.

Panel compatibility & string sizing

NLR SAM inverter library · NLR PVWatts v8 · CEC PV Module List · Cali-Graf calculation
BDM-800-277A: max DC 55 V · MPPT 22–55 V (CEC test window)

Most-permitted panels in Southern California

PanelPowerVoc cold / Vmp hotCheckDC/ACInstalled together
Qcells Q.PEAK DUO BLK ML-G10.C+ 410410 W48.1 / 30.6 V✓ Within range0.51—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W48.1 / 30.6 V✓ Within range0.51—
LONGi LR5-54HABB-400M400 W39.3 / 25.3 V✓ Within range0.5—
JA Solar JAM54S31-405/MR405 W39.4 / 25.5 V✓ Within range0.51—
Hyundai Solutions HiN-T440NF(BK)440 W40.9 / 27 V✓ Within range0.55—
Silfab Solar SIL-440QD440 W41.1 / 28 V✓ Within range0.55—
Qcells Q.TRON BLK M-G2+ 430430 W41.3 / 28 V✓ Within range0.54—
Qcells Q.TRON BLK M-G2.H+ 430430 W41.3 / 28 V✓ Within range0.54—
REC Group REC460AA Pure-RX460 W68.8 / 47.1 V✗ Cold Voc above max input0.58—
Elin (Sirius PV) ELNSM54M-HC-410410 W39.3 / 25.3 V✓ Within range0.51—
Qcells Q.TRON BLK M-G2.C+ 430430 W41.3 / 28 V✓ Within range0.54—
Tesla TSP-420420 W43.4 / 27.7 V✓ Within range0.53—
Voltage check only, from CEC panel data and NLR weather for the city. Final design must follow the inverter manual and NEC 690.7.

About Northern Electric & Power

CEC Grid Support Inverter List (Oct 7, 2026)

Other series

BDHX-xxxxT-208BDM-xxxx-LVBDM-xxx-208ABDM-xxx-240ABDM

Questions & answers

How efficient is the Northern Electric & Power BDM-xxx-277A?

The California Energy Commission lists a weighted efficiency of 96.5% for Northern Electric & Power BDM-xxx-277A models, measured at six power levels and three DC voltages.

Is the Northern Electric & Power BDM-xxx-277A certified to UL 1741 SB?

Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.

What is the BDM-800-277A’s DC input voltage range?

CEC tested it at 22–55 V DC.

Sources

  1. California Energy Commission — Grid Support Inverter List (solar and battery inverters), data as of Oct 7, 2026. Manufacturer-reported, confirmed by CEC against certificates and test reports.
  2. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Riverside, Santa Clarita, Chula Vista, Huntington Beach.
  4. California Energy Commission — PV Module List (module electrical data for the compatibility check).
  5. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).