Microinverter. 8 models, 300 W–2 kW AC at 240 V.
| Model | Nominal AC | Grid voltage | CEC continuous | Rated AC (SAM) | CEC weighted eff. | DC test window | CEC listed | UL 1741 SB |
|---|---|---|---|---|---|---|---|---|
| BDM-300-240A | 300 W | 240 V | 289 W | 289 W | 96.5% | 22–55 V | May 1, 2024 | SB |
| BDM-350-240A | 350 W | 240 V | 346 W | 346 W | 96.5% | 22–55 V | May 1, 2024 | SB |
| BDM-400-240A | 400 W | 240 V | 398 W | 398 W | 96.5% | 22–55 V | May 1, 2024 | SB |
| BDM-800-240A | 768 W | 240 V | 772 W | 772 W | 96.5% | 22–55 V | Aug 11, 2021 | SB |
| BDM-1000-240A | 1 kW | 240 V | 934 W | 934 W | 96.5% | 22–55 V | May 13, 2024 | SB |
| BDM-1200-240A | 1.2 kW | 240 V | 1.22 kW | 1.22 kW | 96.5% | 22–55 V | Jun 3, 2024 | SB |
| BDM-1600-240A | 1.6 kW | 240 V | 1.53 kW | 1.53 kW | 96.5% | 22–55 V | Jun 3, 2024 | SB |
| BDM-2000-240A | 2 kW | 240 V | 2 kW | 2 kW | 96.5% | 22–55 V | Jun 3, 2024 | SB |
| Panel | Power | Voc cold / Vmp hot | Check | DC/AC | Installed together |
|---|---|---|---|---|---|
| Qcells Q.PEAK DUO BLK ML-G10.C+ 410 | 410 W | 48.1 / 30.6 V | ✓ Within range | 0.44 | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 410 | 410 W | 48.1 / 30.6 V | ✓ Within range | 0.44 | — |
| LONGi LR5-54HABB-400M | 400 W | 39.3 / 25.3 V | ✓ Within range | 0.43 | — |
| JA Solar JAM54S31-405/MR | 405 W | 39.4 / 25.5 V | ✓ Within range | 0.43 | — |
| Hyundai Solutions HiN-T440NF(BK) | 440 W | 40.9 / 27 V | ✓ Within range | 0.47 | — |
| Silfab Solar SIL-440QD | 440 W | 41.1 / 28 V | ✓ Within range | 0.47 | — |
| Qcells Q.TRON BLK M-G2+ 430 | 430 W | 41.3 / 28 V | ✓ Within range | 0.46 | — |
| Qcells Q.TRON BLK M-G2.H+ 430 | 430 W | 41.3 / 28 V | ✓ Within range | 0.46 | — |
| REC Group REC460AA Pure-RX | 460 W | 68.8 / 47.1 V | ✗ Cold Voc above max input | 0.49 | — |
| Elin (Sirius PV) ELNSM54M-HC-410 | 410 W | 39.3 / 25.3 V | ✓ Within range | 0.44 | — |
| Qcells Q.TRON BLK M-G2.C+ 430 | 430 W | 41.3 / 28 V | ✓ Within range | 0.46 | — |
| Tesla TSP-420 | 420 W | 43.4 / 27.7 V | ✓ Within range | 0.45 | — |
| Inverter | Power | CEC weighted eff. | DC test window | UL 1741 SB | Latest CEC | SoCal permits |
|---|---|---|---|---|---|---|
| Northern Electric & Power BDM-xxx-240A | 300 W–2 kW | 96.5% | 22–55 V | Yes | 2024 | 0 |
| Hoymiles HM-xxxNT | 295 W–1.44 kW | 96.5% | 29–48 V | 11 of 12 | 2023 | 3 |
| FOXESS M1-1000-NA | 1 kW–1 kW | 95.5% | 35–50 V | Yes | 2026 | — |
| FOXESS M1-xxxx-NA | 600 W–1.2 kW | 95.5% | 35–50 V | Yes | 2026 | — |
| Hoymiles MIS-xxx-2NA | 638 W–958 W | 97.0% | 27–48 V | Yes | 2025 | — |
The California Energy Commission lists a weighted efficiency of 96.5% for Northern Electric & Power BDM-xxx-240A models, measured at six power levels and three DC voltages.
The CEC list includes 8 models from 300 W to 2 kW AC: BDM-300-240A, BDM-350-240A, BDM-400-240A, BDM-800-240A, BDM-1000-240A, BDM-1200-240A, BDM-1600-240A, BDM-2000-240A.
Yes — the CEC Grid Support Inverter List shows UL 1741 SB for all models.
CEC tested it at 22–55 V DC.